midocean MO8426 Smoke Detector User Manual
- June 6, 2024
- midocean
Table of Contents
midocean MO8426 Smoke Detector
Hereby, MOB, declares that item MO8426 is in Compliance with the essential requirements and other relevant conditions of Directive 2014/30/EC. The full text of the EU declaration of conformity is available at the following internet address : www.momanual.com.
Product specifications:
- Battery: 1 x 9V 6F22
- Alarm output: ≥85dB/3m
- Operation temperature: -10°C – 40°C
- Operation humidity: ≤95% Relative humidity with no water condensing
- Quiescent current: ≤12μA
- Alarming current: ≤20mA
- Dimensions: 36mm x 102mmØ
- Weight: 140g
- LED indicator: Red LED
- Hush status: LED flashes every 10s
- Standby status: LED flashes every 43s
- Low battery status: Beep around every 43s and need battery
Installation
- Choose an appropriate position to install the alarm on a ceiling away from obstructions, doors, windows, ventilator and radiator and at least 50cm from fluorescent lights and low energy bulb.
- Use the screws and plugs provided to secure the installation panel securely to the ceiling.
- Align the 2 locating slots in the smoke detector with the 2 tags on the installation panel and rotate it clockwise until it locks into position.
Testing and usage
- Turn the smoke detector anti-clockwise to remove it from the installation panel.
- Install the 9V battery supplied and ensure it is clipped behind the red security arm at the side of the panel.
- Align the 2 locating slots in the smoke detector with the 2 tags on the installation panel and rotate it clockwise until it locks into position.
- Press and hold the TEST/HUSH button. The LED flashes
quickly and the detector sounds. This means the detector works properly. At that time, the detector turns to a low sensitive detection mode. After 10 minutes, it turns to the standard sensitive detection mode.
Notice:
- The only replaceable part is the battery. No user serviceable parts inside.
- Any repairs should be carried out by qualified personnel.
- Test the alarm weekly and every time the battery is replaced.
- Do not use in damp, dusty and smoky environments.
- Test the alarm for normal operation using the test facility when the battery is replaced.
- Replace the smoke detector after 8 years of use.