MOMMED D1ZwM0mRQGL Baby Thermometer User Manual

June 13, 2024
MomMed

MOMMED D1ZwM0mRQGL Baby Thermometer

Product Specification

The main unit is consist of shell. LCD display. sensor and control circuit.

Digital Thermometer InstructionMOMMED D1ZwM0mRQGL Baby Thermometer
1

Thank you for purchasing this product. For safety and proper use of this product, please read and fully understand the safety precautions in this manual. Please keep these instructions for reference in the future.

This thermometer conforms to all of the requirements established in ASTM standard E1112. Full responsibility for confom1ance of this product to the specification is assumed by Guangdong Genial Technology CO., Ltd. , address is 1-6-05-02, 11th Road, Area B, Guangfozhao Economic Cooperation Zone, Zhagang Town, Huaiji County, Zhaoqing City, Guangdong Province, 526437, P.R. China.

Intended Use
This digital thermometer is for home use and/or medical departments for the measurement of human body temperature.

Product performance

Product Name| Digital Thermometer| Product Model| T25, T26, T28
---|---|---|---
Unit switch| ·crF Switchable| Display| LCD Display. 4 1/2
Measurement range| 32.0°C-42.0°C (89.6’F-107.6’F)| Measure Mode| Direct mode
Measurement position and reference body| Oral, Axillary and Rectal (switchable)| Intended use locations| home, medical department
__

Measuring error

| In normal room temperature 25°C

32.00″C-35.29″C, ±0.3″C:  35.30°C-36.99″C, ±0.2″C,

37.00″C-39.00″C. ±0.1°C:  39.01″C-42.00°C. ±0.2″C,

Memory| Display the last measured value (T26, T28) and can be checked the recent 9 set of measurements
Battery life| Approximately 200 hours| Shell protection| IP22
Running Mode| Continuously running| Power| Less than 0.5W
Battery| One 3.0V DC button battery (Model CR2032)| Shock-proof type| Internal power Type BF applied part
Back light color definition: Adaptation model T28| When the measured value is less than 37.50°C(99.50°F), a green backlight is displayed;

When the measured value is 37.50°C-38.49°C(99.50°F-101.28°F), a blue backlight is displayed;

When the measured value is Greater than or equal to than 38.50°((101.30°F), a red backlight is displayed;
__

Using environment

| Temperature: 1o·c-40°C (50″F-104″F) Relative humidity: 15-95% non-condensing Atmospheric pressure:86kPa-106kPa
Storage and transportation condition| Temperature: -2s·c-55•c (-13’F-131’F) Relative humidity: 15-95% non-condensing Atmospheric pressure:50kPa-106kPa
Dimension| 12.7cmX4.1cmX2cm(LXWXH)
Weight| Approximately 33grams including battery
Service life| 5 years

Contraindication
Conducting self-diagnosis based on the measurement results and/or treatment can be dangerous. Please follow the instructions of your doctor. Self- diagnosis may worsen the  symptoms.

Caution and warning

  1. Do not apply a strong shock to, drop, step on, or vibrate the main unit.
  2. Only the sensor is waterproof, the main unit is not waterproof. Be careful when handling this unit so that no liquid (alcohol, water, or hot water) will get into the main unit.
  3. The sensor and flexible tip can be disinfected with alcohol, the other parts can only be wiped lightly with a soft dry cloth. Do not immerse the main unit into water or any other liquid.
  4. Do not disassemble, repair, or modify the unit except battery replacement.
  5. Do not store or keep in direct sunlight, at high temperatures. or in any chemical liquid conditions, in case of chemical changes that effect the operation function and measurement accuracy.
  6. Properly dispose of the batteries according to local regulations keeping them from small children and heat.
  7. Please store this product in a well ventilated and dry place
  8. Equipment shall not be serviced or maintained while in use with a patient.
  9. The patient is an intended user. The patient can use and maintain the device and its accessories according to this manual.
  10. The device and accessories are to be disposed of according to local regulations after their service lives. Alternatively, they can be returned to the dealer or the manufacturer for recycling or proper disposal.
  11. It should be cleaned before each use.
  12. Keep the unit out of children’s reach.

Installation and use

  1. Clean the thermometer using isopropyl alcohol or soap and water. Do not immerse in liquid.
  2. How to switch measuring mode: With the thermometer off, press the SET button, the buzzer will beep. Short press the SET button(by holding for under 2 secs) to choose measuring mode-Oral, Armpit or Anal measuring location. Once you have chosen your measuring setting, wait for 2secs and this location will be selected and you can start to measure.
  3. How to switch between Celsius and Fahrenheit: With the thermometer off, hold the SET button for 5 secs until the buzzer beeps, Short press the SET button the alter from C to F and vice versa. Stop pressing the set key for 2 seconds, it will return to the measurement screen automatically.
  4. Press the switch button, turn on the LCD full-screen display full {buzzer beeps, backlight green on) for about 2 seconds to display the last measurement result, and the symbol m lasts for about 2 seconds. (the backlight will display the relevant color according to the last measured value.) If the measured value cannot be obtained, the next screen is displayed directly. When the backlight is turned off and displays 0, the buzzer will beep and enter the measurement mode after flashing twice at the unit C/° F1 Hz frequency.
  5. Place the sensor in the appropriate measuring position. If the temperature measurement result is lower than 37.50°C(99.50° F), the buzzer will sound continuously for 4 seconds and give along warning sound. If the measured temperature is greater than or equal to 37.50°C(99.50° F), the buzzer will give a short warning sound for 4 seconds. The corresponding backlight color will turn on and turn off automatically after 6 seconds.
  6. If the measured temperature (below)<32.00 °0c (89.6° F), the display of Lo, C / ° F, will flash until it is switched off automatically or manually. If the measured temperature (greater than or equal to) 42.00 °C(l07.6 ° F), the display of Hi, C/° Funits will flash until it is automatically or manually turned off.
  7. Nine groups of memory function
  8. If you press the set key in the display memory for 2 seconds to enter the memory view mode and display m — and then press the set key to view the memory and display. After 1 second, the temperature value measured by the first group is displayed, and the corresponding backlight color appears. Press the set key to switch to the next value, repeat the same process, and you can cycle through 9 groups of measured values. (the backlight color corresponds to the measured value, m flashes at 1Hz)
  9. After entering the memory screen, if you do not press this button within 4 seconds, the device will turn off automatically.
  10. Take it out of the storage case and let it stand for half an hour before measuring.
  11. The probe is the applied part.

ORAL USE
Place the probe tip under the tongue as near as possible to the heat pocket. Approximate measurement: 9 seconds {buzzer sound at the end of measurement).
Suggestion : To measure body temperature more accurately,close your mouth at least 1 minutes before temperature taking.

AXILLARY USE
Wipe the armpit with a dry towel and place the probe under the arm so that the probe tip contacts the skin and the thermometer is perpendicular to the body. Place the arm on the chest so that the tip of the probe is completely covered by the arm. Approximate measurement time: 9 seconds (buzzer sound at the end of measurement).
Note : axillary temperature is usually 0.5°C / 1.0° F lower than an oral temperature.
Suggestion : To measure body temperature more accurately, close the armpit for at least 5 minutes before taking the temperature.

RECTAL USE
Always use a probe cover when taking rectal measurements.

  • Commonly used for young children when it is difficult to take an oral or underarm temperature.
  • Lubricate with a water-soluble gel.
  • Gently insert the probe tip no more than 1.3cm into the rectum. Do not force the tip into the rectum if resistance is encountered.
  • Disinfect the thermometer after use. Approximate measuring time: 9 seconds (buzzer sound at the end of measurement).

Measurement Tips

It is recommended to measure temperature orally, which is close to the human normal body the temperature of between 36.0°C-37.0°C(96.8° F-98.6° F)

  1. Armpit measurement : the armpit temperature of the human body is relatively unstable, and is easily affected by the ambient temperature and measurement method. Therefore, special attention should be paid before measurement. The arm should naturally sag and the armpit should be closed for 5 minutes to stabilize the armpit temperature. Switch the measuring position to the armpit mode, place the thermometer probe in the center of the armpit, clamp and start the measurement.
  2. Oral measurement : oral temperature is relatively stable. Before measurement, the mouth should be closed for about 1 minute. Do not eat or drink (hot food or drinking will increase the body temperature, and cold food or drinking will reduce the body temperature). Switch the measurement position to the oral mode, ‘, and then place the sensor under the tongue.
  3. Anal measurement: to facilitate the insertion of the thermometer, a Vaseline lubrication sensor can be used and the probe is inserted into the patient’s rectum about 1 cm (less than 1 / 2 inch) for measurement.

Product cleaning and maintenance

  1. Gently remove the dirt from the thermometer with a soft dry cloth. According to the requirements of ws310.2 hospital disinfection and supply center part 2: Technical Specification for cleaning, disinfection and sterilization, 75% alcohol can be used to disinfect the sensor part.
  2. Do not store the thermometer in direct sunlight, high temperature and humidity, dust, near fire or areas vulnerable to vibration.
  3. When the thermometer is not used for more than 3 months, the battery should be removed to avoid battery leakage.
  4. When the battery symbol “¢” appears on the screen, ii means that the battery is low, and the battery needs to be replaced as soon as possible.MOMMED D1ZwM0mRQGL Baby Thermometer 3
  5. This product uses special chip and sensor, stable performance and reliable quality. In case of abnormal conditions, consult the manufacturer or the company designated by the manufacturer.
  6. The thermometer does not need to be calibrated during its service life. If there is any abnormality during use or you need to be calibrated, please contact the manufacturer.

Configuration list

Attachments

  • Digital thermometer 1 pcs
  • User manual 1 pcs
  • Cr2032 button battery (built-in) 1 pcs
  • Transparent storage box 1 pcs

Table 1:

Declaration – electromagnetic emission

  • Emissions test Compliance
  • RF emissions CISPR 11 Group 1
  • RF emissions CISPR 11 Class B

Table 2:

Declaration – electromagnetic immunity

Immunity test IEC 60601 test level| Compliance level
Electrostatic                           ±8 kV contact

discharge (ESD)                   ±2 kV, ±4 kV, ±8 kV,

IEC 61000-4-2                       ±15 kV air

Power frequency

(50/60 Hz)                             30 A/m

magnetic field

IEC 61000-4-8

| ±8 kV contact

±2 kV, ±4 kV, ±8 kV, ±15 kV air


30 A/m

NOTE: Ur is the a.c. mains voltage prior to application of the test level.

Table 3:

Declaration – electromagnetic immunity

  • Immunity test IEC           60601 test level                              Compliance level
  • Radiated RF                                 10V/m                                                      10V/m
  • IEC 61000-4-3                            80 MHz to 2.7 GHz

Graphic symbol descriptionMOMMED D1ZwM0mRQGL Baby Thermometer
4

Electromagnetic Compatibility

  • Digital thermometers T25, T26, T28 meet the Standard IEC60601-1-2 relative requirement for Electromagnetic Compatibility.
  • Users can install and use in accordance with the Electromagnetic Compatibility of the instruction booklet.
  • Portable and mobile RF communication equipment may affect the performance of the digital thermometer. Please avoid strong electromagnetic interference when using the product, such as near mobile phones, microwaves etc.
  • Please check the attachment for details of guidance and the manufacturer’s declaration.
  • Equipment or systems should not be used or stacked with other devices. If needed, verify that they can operate properly under the configuration.
  • In addition to the equipment sold by the manufacturer as a spare part of the internal components, the use of accessories and cables other than those specified may result in an increase in the transmission of the equipment or system or a reduction in immunity.
  • Operation of equipment or system at less than the minimum or minimum value specified in this manual may result in inaccurate consequences.

CONTENT OF EMC

  1. WARNING : Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.”
  2. WARNING : Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.”
  3. WARNING : Portable RF communications equipment (including peripherals such as antenna cables and ex1ernal antennas) should be used no closer than 30 cm (12 inches) to any part of the Digital Thermometer, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.”

GUANGDONG GENIAL TECHNOLOGY CO., LTD.
1-6-05-02, 11th Road, Area B, Guangfozhao Economic Cooperation Zone,
Zhagang Town, Huaiji County, Zhaoqing, Guangdong, 526437, China
Mail: [email protected]
Website:www.mommed.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MomMed User Manuals

Related Manuals