Switch off the mains voltage
-
Remove the existing lighting
Detach the existing lighting and disconnect the wires. Do not exceed the maximum load: 2000W. -
Connect the live and neutral wire
Connect the live wire to the outer left [L] terminal. Connect the neutral wire to the outer right [N] terminal. Tighten the clamping screws. -
Connect the switch wire and neutral wire to the lamp
Connect the (black) switch wire from the lamp to the [LL ] socket.
Connect the (blue) neutral wire from the lamp to the left [N] contact. -
Switch on the mains power (electric meter box) to continue the installation
Shock hazard! Do not contact any exposed wiring. Only touch the plastic housing of this product. -
Activate learn-mode
Press the learn button on the receiver for 1 second. The learn-mode will be active for 12 seconds and the LED indicator will blink slowly. -
Assign Trust Smart Home transmitter code
While the learn-mode is active, send an ON-signal with any Trust Smart Home transmitter to assign the code to the receiver’s memory. -
Code confirmation
The LED will flash fast to confirm the code has been received. The receiver can store up to 32 different transmitter codes in its memory. The memory will be preserved when the receiver is moved to another location or in case of power failure. -
Mount the receiver in the box
Mount the receiver in the wall or ceiling box (break off the mounting tabs if necessary) and cover it up with a blind cover or mount the light back onto the ceiling again. -
Manual operation with a Trust Smart Home transmitter
Press ON to switch the receiver on
Press OFF to switch the receiver off
Single code delete
A Press the learn button for 1 second. The learn-mode will be active for
12 seconds and the indicator will blink slowly.
B While the learn-mode is active, send an OFF signal of a specific Trust
Smart Home transmitter to delete that code.
C The LED will flash fast to confirm code deletion.
Full memory delete
A Press and hold the learn button on the receiver (approx. 6 sec.) until
the LED indicator starts blinking fast. The delete mode will be active for 12
seconds.
B While the delete mode is active, press the learn button again for 1
second.
C The LED will flash fast to confirm the memory has been cleared.
Safety Instructions
Product support: www.trust.com/71269. Warranty conditions:
www.trust.com/warranty
To ensure safe handling of the device, follow the safety advice on:
www.trust.com/safety
The Wireless range is strongly dependent on local conditions such as the
presence of HR glass and reinforced concrete
Never use Trust Smart Home products for life-support systems. This product is
not water-resistant. Do not attempt to repair this product. Wire colors may
vary per country. Contact an electrician when in doubt about wiring. Never
connect lights or equipment that exceed the maximum load of the receiver.
Exercise caution when installing a receiver voltage may be present, even when
a receiver is switched off.
| Disposal of packaging materials – Dispose of packaging materials that are no
longer needed in accordance with applicable local regulations.
---|---
| Disposal of the device – The adjacent symbol of a crossed-out wheelie bin
means that this device is subject to Directive 2012/19/EU.
| Disposal of batteries – Used batteries may not be disposed of in the
household waste. Only dispose of batteries when they are fully discharged.
Dispose of batteries according to local regulations.
| Trust Electronics Ltd. declares that item number 71269 is in compliance with
Directive Electromagnetic Compatibility
Regulations 2016 and Radio Equipment Regulations 2017. The full text of the
declaration of conformity is available at
the following internet address: www.trust.com/
| Trust International B.V. declares that item number 71269 is in compliance
with Directive 2014/53/EU – 2011/65/EU.
The full text of the EU declaration of conformity is available at the
following web address: www.trust.com
Declaration of Conformity
Trust International B.V. declares that this Trust Smart Home-product:
Model: | ACM-2000 Build-IN SWITCH |
---|---|
Item number: | 71269 |
Intended use: | Indoor |
is in compliance with the essential requirements and other relevant provisions
of the following directives:
ROHS 2 Directive (2011/65/EU)
RED Directive (2014/53/EU)
TRUST SMART HOME
LAAN VAN BARCELONA 600
3317DD DORDRECHT
NEDERLAND
www.trust.com
Trust Electronics Ltd.,
Sopwith Dr, Weybridge, KT13 0NT, UK.
All brand names are registered trademarks of their respective owners.
Specifications are subject to change without prior notice.
Made in China.
www.trust.com
References
- Trust.com - Contact & Support - Compliance
- Trust.com - Home
- Trust.com - Home
- Trust.com - Built-in Switch ACM-2000
- Trust.com - Contact & Support - Compliance
- Trust.com - Contact & Support - Safety information
- Trust.com - Contact & Support - Warranty conditions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>