MASTECH MS5208 Digital Insulation Multimeter User Guide

June 6, 2024
MASTECH


Quick Start Guide
MS5208
Digital Insulation Multimeter

CAT III 1000V

1 YEAR
LIMITED WARRANTY

700019229 June 2021 Rev. 1
Specifications are subject to change without notification.

Special attention should be paid when using the test and measurement instrument because improper usage may cause electric shock and damage the equipment.

  • Use proper measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Do not use or store the device around explosive gas, vapor, or under high temperature and humidity.
  • When handling the test probes and crocodile clips, keep your fingers behind the physical guard.
  • Examine the measuring test leads (if present) before use. Any element of which the insulation deteriorates (even partially), replace them with proper functional test leads.
  • Connect the common test lead before the live test lead and remove the live test lead before the common test lead.
  • Before measuring current, make sure the instrument fuses available and disconnect the power supply to the circuit test
  • Remove the batteries if the device is not used for an extended period of time, or if stored in temperatures above 45 °C. If the batteries are not removed, battery leakage can damage the device.

Contents

Specifications

| Range| Resolution| Accuracy
---|---|---|---
V~| 660mV/6.6V/66V/660V/750V| 0.1mV/1mV/10mV/0.1V/1V| ±(1.5%+30)
V| 660mV/6.6V/66V/660V/1000V| 0.1mV/1mV/10mV/0.1V/1V| ±(0.5%+5)
A~| 66mA/400mA| 10μA/0.1mA| ±(1.5%+30)
A| 66mA/400mA| 10μA/0.1mA| ±(1.0%+5)
Ω| 660Ω/6.6kΩ/66kΩ/660kΩ
6.6MΩ/66MΩ| 0.1Ω/1Ω/10Ω/0.1kΩ
1kΩ/10kΩ| ±(1.2%+5)
±(2.0%+20)
| 66nF/660nF/6.6μF/66μF
660μF/6.6mF/66mF| 10pF/0.1nF/1nF/10nF
0.1μF/1μF/10μF| ±(5.0%+20)
±(5.0%+20)
Hz%| 660.0Hz/6.600kHz/66.00kHz

10kHz| 0.1Hz/1Hz/10Hz
10Hz| ±(1.5%+5)
Reference
°C/°F| -30℃~1300℃
-22℉~2372℉| 1℃
1℉| ±(1.0%+2)
±(1.0%+4)

V   V~

A A~

Hz/Duty

°C/°F

Insulation

USA
MGL AMERICA, INC.
2810 Coliseum Centre Drive,
Ste. 100 Charlotte,
North Carolina 28217 USA
Tel: +1 833-533-5899
Email: cs.na@mgl-intl.com| UNITED KINGDOM
MGL GROUP U.K. LIMITED
14 Weller St, London, SE1 1QU, UK
Tel: +34 985-08-18-70
Email: cs.uk@mgl-intl.com
---|---

SKU Number: MS5208CBGLO