DRAZICE TO 5.1 UP IN Electric Water Heater User Manual
- June 6, 2024
- Drazice
Table of Contents
- PRODUCT ACCESSORIES
- MESSAGE FOR CUSTOMERS
- TECHNICAL DESCRIPTION
- GENERAL TECHNICAL DATA
- OPERATING ACTIVITY
- WALL MOUNTING
- PLUMBING FIXTURE
- ELECTRIC INSTALLATION
- HEATER COMMISSIONING
- IMPORTANT NOTICE
- FUNCTIONAL DEFECTS
- FIRE-FIGHTING REGULATIONS FOR INSTALLATION AND USE OF HEATER
- USE AND MAINTENANCE OF HEATER
- INSTALLATION REGULATIONS
- FRONT PANEL
- **FIGURE
- Documents / Resources
OPERATING AND
INSTALLATION MANUAL
ELECTRIC WATER HEATER
TO 5.1 UP/IN
TO 10.1 UP/IN.
Cooperative plants s.r.o.
tel.: +420 / 326 370 911
fax: +420 / 326 370 980
e-mail: export@dzd.cz
CAREFULLY READ THIS MANUAL BEFORE INSTALLING THE WATER HEATER!
Dear Customer,
Cooperative plants s.r.o. , would like to thank you for your decision to
use a product of our brand. With this guide, we will introduce you to the use,
construction, maintenance, and other information on electrical water heaters.
The product is not intended to be controlled by
a) people (including children) with reduced physical, sensual, or mental
capacities, or
b) people with insufficient knowledge and experiences unless supervised by a
responsible person, or unless properly instructed by such a responsible
person.
The manufacturer reserves the right for engineering modification of the
product. The product is designed for permanent contact with drinkable water.
It is recommended to use the product in an indoor environment with air
temperatures from +2 °C to +45 °C and relative humidity up to 80 %.
The product’s reliability and safety is proven by tests implemented by the
Engineering Test Institute in Brno. Made in the Czech Republic.
To ensure proper functioning, the water heater must be connected to a
permanent power supply. The electrical installation may only be carried out by
a person authorized to install devices in the electrical area (does not apply
to inserting the plug into the socket).
Meaning of pictograms used in the Manual
Important information for heater users.
Abiding by the recommendations of the manufacturer serves to ensure
trouble-free operation and the long service life of the product.
Caution!
Important notice to be observed.
PRODUCT ACCESSORIES
The product is packed together with service instructions. The heater is equipped with a safety valve as a protective element. The valve is mounted on the cold water supply (see chapter
MESSAGE FOR CUSTOMERS
The water temperature is set by a thermostat to 55 °C. The electrical heater is designed for the preparation of hot water in households, cottages and various welfare facilities. It allows the installation of only one hot water draw-off point with a pressure-free connection. In case of a pressure connection, it is possible to connect more sampling points, but with limited use of simultaneous sampling. Its benefit is that it heats up water by power in an unlimited all-day time range, due to small accumulation, the connection with HDO signal control is not recommended. The time of heating service water is about 9 and 18 minutes, depending on the volume.
TECHNICAL DESCRIPTION
The heater tank is steel enameled for pressure connection, the electrical
heating element is of an immersion type. The heater tank consists of a
magnesium anode that helps protect the heater tank from corrosion. The heater
tank is provided with polyurethane insulation and everything is stored in a
plastic cover. The electrical wiring is placed in the bottom (upper) part of
the heater, under the removable cover of the heater. The water temperature is
set by a thermostat to 55 °C. The cold water inflow is indicated with a blue
ring, hot water outflow is indicated with a red ring.
TO 5.1, 10.1 UP – pressure heater with a capacity of 4.6 and 9.6 liters
located above the consumption point
TO 5.1, 10.1 IN – pressure heater with a capacity of 4.6 and 9.6 liters
located under the consumption point
**The TO 5.1, 10.1 IN/UP heaters can also be used as non-pressure heaters.**
GENERAL TECHNICAL DATA
| | TO 5.1 IN/UP| TO 10.1 IN/UP
---|---|---|---
VOLUME| l| 4.6| 9.6
RATED PRESSURE| bar| 6| 6
ELECTRIC CONNECTION| | 1 PE-N 230V/50HZ
RECOMMENDED BREAKER| | 16 A
INPUT| W| 1500
EL. PROTECTION| | IP X5
MAX. WEIGHT OF THE HEATER WITHOUT WATER (WITH WATER)|
kg
|
6.0 (10.6)
|
8.0 (17.6)
TIME OF EL. HEATING FROM 10 °C TO 60 °C|
min
|
13
|
25
MIXED WATER V40| l| 4.06 / 5.51| 11.2 / 13.38
LOAD PROFILE| | XXS| XXS
ENERGY EFFICIENCY CLASS| | A| A
ENERGY EFFICIENCY| %| 36.24 / 37.10| 35.17 / 35.12
ANNUAL CONSUMPTION OF ELECTRIC ENERGY|
kWh
|
509 / 497
|
525
OPERATING ACTIVITY
After connecting the heater to the mains, the immersion heater heats up the water. The element is turned on and off by a thermostat. After reaching the temperature set, the thermostat switches off the electrical circuit and discontinues water heating. The heat control light signals if the element is in operation (the light is on) or if it is off (the light goes out).
WALL MOUNTING
Prior to mounting check the loading capacity of the wall. If needed, reinforce it. Mount the water heater in a vertical position only. The fastening screws must have a guaranteed spacing of 140 mm. The mounting dimensions are specified in Figure 3.
PLUMBING FIXTURE
Water inflow and outflow is indicated with different color terminals on the
heater tubes. Coldwater supply is indicated with blue and hot water outflow is
indicated with red. There are two ways of connecting the water heater to the
water network. A closed, pressure connection system allows water withdrawal at
multiple supply (withdrawal) points whilst an open flow system allows one
supply (withdrawal) point only. With regard to the selected way of connection,
you need to purchase suitable combination faucets.
For the open flow system, you need to mount a return valve in order to avoid
water outflow from the boiler if the water supply gets discontinued. For this
type of connection, you have to use the flow combination faucet. Due to
heating, the volume of water increases, which causes water to drip from the
combination faucet pipe. You will not prevent water from dripping by the
strong tightening of the combination faucet valve, but you may damage the
combination faucet.
For the closed pressure connection system, you need to use pressurized
combination faucets at the withdrawal points. You have to attach a safety
valve to the filling pipe to avoid an increase of pressure in the tank above
the rated pressure. During water heating in the heater, the water pressure in
the tank increases until it reaches the limit set on the safety valve.
Explanation:
1 – Safety valve
2 – Back pressure valve
3 – Test valve
4 – Reduction valve
5 – Shut-off valve
6 – Test adaptor
7, 7a – Flow combination faucet
8 – Funnel with connector to drain from the safety valve
H – Coldwater
T – Hot water
Safety valve is mounted on the cold water inlet identified with a blue ring.
Each hot service water pressure heater must have a safety valve with a
membrane spring. Nominal clearance of safety valves is defined in the ČSN 06
0830 standard. The safety valve must be well accessible, as near to the heater
as possible. The input pipes must have at least the same clearance as the
safety valve. The safety valve is placed high enough to secure dripping water
drain by gravity. We recommend mounting the safety valve onto a branch pipe.
This allows easier exchange without having to drain the water from the heater.
Safety valves with fixed pressure settings from the manufacturer are used for
the assembly. Starting pressure of a safety valve must be identical to the
maximum allowed heater pressure, and at least 20 % higher than the maximum
pressure in the water main. If the water main pressure exceeds such value, a
reduction valve must be added to the system.
No stop valves can be put between the heater and the safety valve.
During the assembly, follow the guide provided by the safety equipment
manufacturer. It is necessary to check the safety valve each time before
putting it into operation. It is checked by the manual moving of the membrane
from the seat, turning the make-and-break device button always in the
direction of the arrow. After being turned, the button must click back into a
notch. Proper function of the make-and-break device results in water draining
through the safety valve outlet pipe. In common operation, such a check needs
to be implemented at least once a month, and after each heater shut down for
more than 5 days. Water may be dripping off the drainpipe of the safety valve;
the pipe must be open into the air, pointed down; environment temperatures
must not drop below zero. When draining the heater, use a recommended draining
valve. First, close water input into the heater
Find necessary pressure values in the following table – Table 2.
SAFETY VALVE STARTING
PRESSURE [MPa]| ADMISSIBLE OPERATING
WATER HEATER PRESSURE
[MPa]| MAX PRESSURE IN THE
COLD WATER PIPE [MPa]
---|---|---
0.6| 0.6| up to 0. 48
For proper safety valve operation, a backflow valve must be mounted on the
inlet pipes, preventing spontaneous heater draining and hot water penetrating
back into the water main .
We recommend that the hot water distribution from the heater was as short as
possible to minimize heat losses.
Heaters TO UP must be provided with a discharge valve mounted on the cold
service water inlet to the heater for potential disassembly or repair.
When assembling the security equipment, follow the standard.
ELECTRIC INSTALLATION
The electrical wiring scheme is attached in the manual to the water heater
(Figure 4). The heater must be connected via a separate supply with a circuit
breaker. The heater is connected to the 230V/50Hz mains with a power cable by
inserting the plug into the socket. The electrical installation must comply
with valid electrical and technical standards. The connection of the heater to
the electrical network is made after the water supply installation of the
heater and the filling of the heater with water.
Follow the rules of protection against electrical injuries in accordance with
standard CSN 33 2000 – 4 – 41.
The degree of protection of the electrical parts of the heater is IP X5.
HEATER COMMISSIONING
After connecting the heater to the water supply network, the heater can be put
into operation. Before opening the power supply, the tank must be filled with
water. The process of first heating must be executed by licensed professional
who has to check it. Both the hot water outlet pipe and safety armature parts
may be hot.
Procedure:
a) check the electric and water main installation
b) open the hot water valve on the combination faucet
c) open the cold water inlet valve to the heater
d) as soon as the water starts running through the hot water valve, the heater
is filled and the valve closes
e) using the front-end main switch open electricity and thus the heater
activates
Before first use, or after longer periods, it is necessary to ensure flushing,
irrigation and ventilation heater before starting the heating. The first
heating tank must be monitored.
IMPORTANT NOTICE
- Without a confirmation issued by an authorized company about performed electrical and plumbing fixture, the warranty certificate shall be void.
- The hot water outlet must be equipped with a combination faucet.
- It is not allowed to handle the thermostat in any manner whatsoever, aside from temperature resetting with a control button.
- All-electric installation handling, adjustment and replacement of the regulation elements shall only be performed by an authorized service company.
- The thermal fuse must not be turned off! The non-reversible thermal fuse discontinues electric power input to the heating element should the thermostat fail, if the water
temperature in the heater exceeds 99 °C.
. If the water heater is mounted in enclosed areas, inter-ceilings, built-in structures, and recesses ensure sufficient access to service fittings, electrical terminal boards, anodes, and manholes. The minimum spacing from the manhole is 200 mm.
10.1 DISPOSAL OF PACKAGING MATERIAL AND FUNCTIONLESS PRODUCT
A service fee for providing return and recovery of packaging material has been
paid for the packaging in which the water heater was delivered. Was paid
pursuant to Act No. 477/2001 Coll., as amended, at EKO-KOM a.s. The client
number of the company is F06020274. Take the product packages to a waste
disposal place designated to that purpose by the municipality. When the
operation terminates, disassemble, and transport the discarded and
unserviceable heater to a waste recycling center (collecting yard), or contact
the manufacturer.
FUNCTIONAL DEFECTS
DEFECT | FAILURE | |
---|---|---|
The water in the tank is cold | · LED is on | · heating element failure |
The water in the tank is not warm enough | · LED is on | · heating element |
failure
The water in the tank is cold| · LED is not on| · operating thermostat
failure – safety thermostat shut off power supply
· power supply outside the heater discontinued
Water temperature in the tank does not correspond with value set| |
· thermostat failure
Do not attempt to repair the faults yourselves. Contact either a professional or service center. It does not take much for a professional to remove the fault. When arranging a repair appointment, state the type and serial number you find on the rating plate of your water heater.
FIRE-FIGHTING REGULATIONS FOR INSTALLATION AND USE OF HEATER
We would like to emphasize that the heater must not be connected to power supply if work involving flammable liquids (petrol, spot remover) or gases, etc., is performed nearby.
USE AND MAINTENANCE OF HEATER
Once connected to the water and electrical network, the heater is ready for
use.
The operation of the electrical heater is indicated by a signal light that
goes on until the water in the heater is heated to the set temperature. As a
result of the heating, the volume of water increases, which causes the water
to drip from the safety valve.
If you do not intend to use the heater constantly, you need to protect the
water in the heater by not discontinuing the power totally. If you take the
heater off the power supply, you have to drain the water from it if there is a
risk that the water inside freezes. Empty the heater.
Clean the outer parts of the appliance with a mild detergent solution. Do not
use thinners or other concentrated cleaning agents. Regular service
inspections will ensure trouble-free operation and long service life of the
heater.
By repeatedly heating the water, limescale settles on the walls of the tank.
Limescale settling depends on the hardness of the heated water, its
temperature and on the volume of hot water consumed.
We recommend that the first inspection of the heater is carried out by a
specialist, approximately two years after connection.
During the inspection, the scale, that accumulates inside the heater depending
on the quality, amount, and temperature of the water consumed, will be removed
as needed. The service will recommend the date of the next inspection when
inspecting the radiator and taking into account the detected
CAUTION: Prior to any intervention inside the heater, the device must be
disconnected from the mains!
Do not attempt to repair the heater by yourselves, call the nearest authorized
service center to do so.
INSTALLATION REGULATIONS
**** Both the electric and water installation must follow and meet the requirements and regulations relevant in the country of use!
FRONT PANEL
There is a symbol for the signal light of the heater operation.
NAME | FUNCTION DESCRIPTION |
---|---|
Signal light | Indication of active heating |
The front panel is equipped with a protective foil which must be removed
for proper readability of the panel.
**FIGURE
**
16.1 HEATER DIMENSIONS
| A [mm]| B [mm]| C [mm]| D [mm]| E [mm]
---|---|---|---|---|---
TO 5.1 UP| 330| 265| –| 290| 275
TO 5.1 IN| 338| –| 93| 290| 275
TO 10.1 UP| 465| 400| –| 290| 275
TO 10.1 IN| 473| –| 93| 290| 275
①| 1/2″ outer
---|---
16.2 WIRING SCHEME
Key:
1 – thermostat and reversible thermal fuse
2 – Heating element
3 – Operation indicator
4 – Power supply
6-5-2021
www.dzd.cz
Documents / Resources
|
DRAZICE TO 5.1 UP IN Electric Water
Heater
[pdf] User Manual
TO 5.1 UP IN, TO 10.1 UP IN, TO 5.1 UP IN Electric Water Heater, Electric
Water Heater, Water Heater, Heater
---|---