HEM-CR24
Medium Cuff
Instructions for use
HEM-CR24
Thank you for purchasing the OMRON HEM-CR24. Arm circumference for this cuff
is 22 to 32 centimeters. Follow this instruction manual and applicable OMRON
blood pressure monitor manual thoroughly before use. Keep for future
reference. For specific information about your own blood pressure,
CONSULT YOUR PHYSICIAN.
The OMRON HEM-CR24 comes with the following components:
Please refer to the list of compatible models on plastic bags 1 and 2 to know
which plug you must use.
Notes:
- If your unit is not included in the models listed on the plastic bags, please contact the authorized OMRON distributor.
- Please check your present product as to which plug you must use. Connect the correct air plug to the air tube.
Caution: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
- Use only the approved Blood Pressure Monitor for this cuff.
- Do not wash the cuff or make it wet.
- Do not fold the cuff or air tube together too tightly and do not crease them.
Instructions for use
Applying the Arm Cuff
- Do not place the cuff over thick clothes and do not roll up your sleeve if it is too tight.
- Align the cuff with the height of your heart (breast height). If necessary use a pillow or cushion.
-
Put your left arm through the cuff loop.
Note: If the cuff is not assembled, pass the end of the cuff furthest from the tubing through the metal D-ring to form a loop. The smooth cloth should be on the inside of the cuff loop. -
Position the arm correctly.
1 )The air tube should run down the inside of your forearm and be in line with your middle finger. 2)The bottom of the cuff should be approximately 1 to 2 cm above your elbow. 3)Apply the cuff to your upper arm so that the mar key (arrow under tube) is centered on the middle of your inner arm and points down the inside of the arm.
Note: The cuff should be at the same level as your heart.
Taking measurements on the right arm
Apply the cuff so that the air tube is at the side of your elbow.
• Be careful not to rest your arm on the air tube, or otherwise restrict the flow of air to the cuff.
• The cuff should be 1 to 2 cm above the elbow. -
When the cuff is positioned correctly, close the fabric fastener FIRMLY.
• Use a soft and moistened cloth and neutral soap to clean the arm cuff.
• Do not store the cuff in the following situations:
If the cuff is wet.
Locations exposed to extreme temperatures, humidity, direct sunlight, dust, or corrosive vapors.
Locations exposed to vibrations, shocks, or where
it will be at an angle.
Specifications:
Product description | Blood pressure monitor cuff |
---|---|
Model | HEM-CR24 |
Arm circumference | 22 to 32 cm |
Cuff pressure range | Pressure: 0 to 299 mmHg |
Operating conditions | +10 to +40°C |
15 to 90% RH (non-condensing) 700 to 1060 hPa
Storage/ Transport conditions| -20 to +60°C 10 to 95% RH (non-condensing) 700
to 1060 hPa
Accuracy| Pressure: ±3 mmHg Pulse: ±5 `1/0 of display reading
Durable period (Service life)| 1 year
Please report to the manufacturer and the competent authority of the Member State in which you are established about any serious incident that has occurred in relation to this device.
Manufacturer| OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho,
Muko, KYOTO, 617-0002 JAPAN
---|---
EU-representative| OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR
Hoofddorp, THE NETHERLANDS www.omron-healthcare.com
Importer in EU
Production facility| OMRON DALIAN CO., Ltd. No. 3, Song Jiang Road,
Economic and Technical Development Zone, Dalian 116600, China
Asia Pacific HQ| OMRON HEALTHCARE SINGAPORE PTE LTD. 438A Alexandra
Road, #05-05/08 Alexandra Technopark, Singapore 119967 www.omronhealthcare-
ap.com
Made in China
This OMRON product is produced under the strict quality system of OMRON
Healthcare Co. Ltd., Japan.
Symbols description
| CE Marking
LOT number
Temperature limitation
Humidity limitation
Atmospheric pressure limitation
Identifier of cuffs compatible for the device
Cuff positioning indicator for the left arm
Range pointer and brachial artery alignment position
Artery mark
Not made with natural rubber latex
Range indicator of arm circumferences to help selection of the correct cuff
size
Reference catalog number
Need for the user to consult the instruction manual
Arm circumference
Medical device
Product production date is integrated in the Lot number, which is placed on
the product and/ or sales package: the first 4 digits mean year of production,
the next 2 digits mean month of production and the last 2 digits mean day of
production.
Depending on the product, some of the above symbols may not be applicable on the product.
All for Healthcare
Issue Date: 2019-10-03
3735530-0C
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>