airbi AIRCV755 Wi-Fi Air Purifier Instruction Manual
- June 6, 2024
- airbi
Table of Contents
- Important safety instructions
- Packing list
- Purifier’s scheme
- Before first use
- Control overview
- Display overview
- Operation instruction
- Connection to WiFi – control by app
- Product care and maintenance
- Filtration system
- Replacing the filters
- Replacing UV lamp
- Troubleshooting
- Technical specifications
- Disposal of the device (environment)
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Air purifier
Airbi SPRING
WiFi
Instruction manual
(version 1.0)
Please read the instruction manual carefully before using this appliance!
Important safety instructions
Please read through the operating instructions carefully before you use the appliance for the first time and keep them safely for later reference. If necessary pass them on to the next owner.
-
The appliance is only to be used in the home for the purposes described in these instructions. Unauthorized use and technical modifications to the appliance can lead to danger to life and health.
-
This appliance can be used by children aged 10 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
-
After unpacking, make sure that the appliance wasn’t damaged during transport. If you find any damage, contact your dealer as soon as possible. We recommend you keep the packaging for possible future use.
-
Before first use check that the device parameters (electric voltage, etc.) correspond to local conditions.
-
Use appliance in an environment of 10°C to 30°C. Do not use outdoors.
-
Please put appliance more than 1 meter away from TV or radio. It is recommended to put
the appliance on a flat ground in the room. -
Do not place the appliance near a heat source. Do not subject the power cord to direct heat
(such as a heated hotplate, open flames, hot iron sole plates or heaters for example). Protect power cords from oil. -
Always put the appliance on a hard, flat horizontal surface. There should be a gap of at least 20 cm at both sides and back of the product, while 30 cm from top surface.
-
Do not place anything on the appliance and do not block the air inlet and outlet.
-
Before using the appliance, check if the AC adapter or power cord is not damaged. Do not use it if the cord is damaged.
-
If the power cord is damaged, it must be replaced by the manufacturer or a repair shop authorized by the manufacturer or by similarly qualified persons in order to avoid a hazard
-
Switch off and unplug the unit before any manipulation such as cleaning of filters maintenance.
-
Do not lift or move the appliance when it is working.
-
Do not touch the power cord with wet hands, may cause electric shock.
-
Do not insert fingers or metal objects into the air outlet gap, may cause electric shock.
-
Do not let water, flammable detergent or other liquid get into the product, may cause the electric shock of fire.
-
This product is not supposed to be used as a daily ventilator, dust cleaner or cooker hood.
-
Do not place appliances in too humid or too hot places.
-
Do not use the appliance in an aromatherapy scent insecticide environment.
-
Store the appliance in a dry place inaccessible to children (pack the appliance).
-
The manufacturer is not responsible for any damage due to improper use of the appliance.
Packing list
appliance remote control filters (3 pcs) user manual
- appliance
- remote control
- filters (3 pcs)
- user manual
Purifier’s scheme
Before first use
Take out filters from appliance Int
-
Open the front cover
-
Take out the filters
-
Remove all packaging material
Install filters and front panel in this order
-
install Antibacterial and HEPA filter – please ensure that tab side is facing you
-
install Cold catalyst and Formaldehyde removal compound filter – please ensure that tab side is facing you
-
install Prefilter – please ensure that tab side is facing you
Install back front panel
Control overview
- switch on/off button
- child lock button
- ionizer button
- timer button
- night mode button
- fan speed button
- auto mode button
- UV lamp button
Display overview
- PM2.5 – particle value
- UV lamp icon
- AUTO mode icon
- NIGHT mode icon
- ionizer icon
- child lock icon
- filter replacement icon
- wifi icon
- fan speed icon
- air quality icon
Operation instruction
| Power button
The appliance is in standby mode after you plug in the power cord to the
socket. Touch the power button. The appliance will start working in AUTO mode.
After you press the power button once again, the appliance will switch off to
standby mode. Remark: The appliance has a front panel switch and an anti-fall
security switch. It won’t turn on when the front panel is removed or the
appliance falls down.
---|---
Child lock button
All buttons will be disabled when pressing child lock. The icon will light up
and keep running. Press this button for 3 seconds to exit this mode.
Ionizer button
Ionizer will on/off when press this button. The icon will light up and down
accordingly.
Timer button
Press this button to set the working time. Every time increase 30 minutes. It
will recycle after 12 hours. Display panel will show 00:30, 1:00, 1:30,
2:00….You can press 3 seconds to exit this mode. As soon as preset time
expires appliance will go into standby mode and exit timer mode.
UV button
Press this button to switch on/off the UV sterilization function. The icon
will light up or down at the same time.
| AUTO button
Press this button to set the appliance into automatic mode. The icon will
light up at the same time. In
this mode appliance automatically adjust fan speed level according to the
degree of air
pollution. PM2.5 <60 (low speed), 60<=PM2.5<150 (medium speed), PM2.5 >=150
(high speed).
---|---
Night mode button
The display panel and light will turn off when sleep mode starts. Motor works
at low
speed. The timer is available at this mode. The appliance will go into standby
mode after the
time setting finishes. Press any button to exit sleep mode.
Speed mode button
Press this button to control fan speed (low, medium, high) and let the
appliance exit auto
mode. The motor speed won’t be controlled by an air quality sensor.
Working time
Press the child lock button for 5 seconds when in normal mode (child lock mode
not active)and you will see accumulated working time of the appliance. It will
disappear after 3
seconds.
Air quality icon
This icon will inform you about the air quality in the room. Green means good,
orange color
means worse quality and red color indicates bad air conditions.
Connection to WiFi – control by app
You can use the application on your smartphone or tablet (iOS, Android) to control the device. Before the device can be controlled via the application, it is necessary to configure the device and allow it to connect to a WiFi network. Instructions for the application and setup of the device can be found at www.airbi.cz/spring-wifi
https://www.airbi.cz/spring-wifi/
Product care and maintenance
Pre-filter (every 15 days)
-
Please use the vacuum cleaner to clean the dust on the surface of the screen or wash with water, dry thoroughly.
Cold-catalyst filter / High effection formaldehyde removing filter (every 2 months)
-
Use the vacuum cleaner to clean the dust on the surface of the screen.
-
Place the filter into the ventilated place. Don’t expose to the strong sunshine.
-
Do not use water to clean the filter.
Antibacterial / True HEPA filter (every 2 months)
-
Use the vacuum cleaner to clean the dust on the surface of the screen.
-
Place the filter into the ventilated place. Don’t expose to the strong sunshine.
-
Do not use water to clean the filter.
Negative ion generator -
When you hear the appliance with a creaking sound, use the brush pen as a cleaning tool, regularly clean the dust around the negative ion.
Particle sensor (every 2 months)
- With a dry cotton swab and regular cleaning the lens to remove the moisture and smoke, remove the outer cover of particle sensor, use the dry cotton swab to clean the lens.
- Please ensure to disconnect the power before cleaning.
- Irradiated with light when it can’t see clearly.
Tips
- Ensure to disconnect the power before cleaning and maintenance.
- Please unplug power if the appliance is not in use in long time.
- According to the use of places and methods (e.g. family with many of smokers or the place with serious pollution), the filter life will be shortened. Please replace the filter in time.
- To clean the device, do not use any aggressive concentrated detergents.
Filtration system
- Pre-filter: Aluminum alloy dust capturing filter at the front, with multi-layer corrugated aluminum nets, low initial resistance, high dust capturing capacity. Is able to filter pollutants like large dust particles, hairs, pollen, suspended particles, etc. Is washable and reusable.
- Cold catalyst filter: the cold catalyst will play a catalyst effect in a normal living environment without any external assistance like UV light, Sunlight, High Temperature or Pressure. It catalyzes the formaldehyde, ammonia, benzene, TVOC, hydrogen, sulfide and other harmful gases to work with oxygen, and then decompose them into water and CO2
- High effection formaldehyde removing filter: This is a removal filter, designed to quickly absorb and decompose formaldehyde. It is made of top-quality material for enhanced durability. This removal filter is an ideal choice for household and office use.
- Antibacterial filter: Antibacterial fabric resists colonization by bacteria to reduce the risk of spreading infection and developing unpleasant odors. Long-lasting protection against unwanted organisms.
- True HEPA filter: Adsorbs particulate down to 0.0001mm like pollen, drifting dust and germs with a purification efficiency of more than 99.9%. Prevention of the spread of airborne bacterial and viral organisms.
- UV lamp: helps clean the air. This feature is optional (it can be turned on or off).
- Anion generator: Double core anion generator releases a large amount of anions and make the oxygen negatively charged. Anions not only remove dust, kill bacteria and purify air efficiently, they also facilitate the synthesis in human bodies and the storage of vitamins.
Replacing the filters
- Pre-filter
- Cold-catalyst filter / High effection formaldehyde removing the filter
- Antibacterial / True HEPA filter
The appliance has a filter change reminding function. It’s set at 1500 hours. Please replace the Formaldehyde/ Cold catalyst filter (no. 2) and Antibacterial/HEPA filter (no. 3) when the “change” icon light up. Also please press the child lock button for 5 seconds to reset this function.
A) Press the middle of the front to make the upper button out of its position.
B) Pull out the front panel.
C) Take out the filters one by one.
D) Fill in new filters one by one in the correct order.
Replacing UV lamp
UV lamp needs to replace 1x during 2-3 years according to its usage.
How to replace UV lamp:
- Unplug the appliance from el. socket, remove the front cover and take out all filters.
- Put flat-blade screwdriver under cover of UV lamp (from bottom left side about 8 cm – 5 rib of cover) and slide it to right side slowly until you release safety lock. After that you can pull the left side of the UV lamp a little bit. In this moment you can pull the UV lamp from contacts on the right side (in the direction to left). th
- Insert UV lamp firstly to contacts on the right side and then push left side to the back of panel until you hear crack sound.
Troubleshooting
Trouble | Solution |
---|
Can not turn on or the button has no
response
| · Check the power cord if is plugged in.
· Check the front plate cover if is covered.
· Check if the appliance is not in Child-lock mode.
· Check if the appliance is on the flat place.
Air is dirty, but the indicator still
show green color.
| The particle sensor is dirty, you have to clean it.
Strange sound during operation.| Negative ion generator has too much
dust, clean it.
Strange smell from the appliance.| Filters are dirty, clean or replace
filters.
Purifier work time is long, but air
quality has not improved.
| · Check if you removed filter bags.
· Check if you install filters incorrect order.
The display shows F l or F2| Please turn off the power immediately and find maintenance
department.
Technical specifications
Rated voltage | 220-240 V, 50/60 Hz |
---|---|
Power | 80 W |
WiFi frequency | 2,4 GHz |
Standard | IEEE 802.11 b/g/n |
Max. radio power | 20 dBm |
Noise | 28/38/55 dB (A) |
Ionizer | 20 million/cm 3 |
Air performance | 320 m 3 /h |
Max. room dimension | 50 m 2 |
Dimensions | 370 x 195 x 665 mm |
Weight | 8,5 kg |
Disposal of the device (environment)
The European directive 2012 / 19 / CE on Waste Electrical and Electronic
Equipment (WEEE), requires that old household electrical appliances must not
be disposed of in the normal unsorted municipal waste stream. Old appliances
must be collected separately in order to optimize the recovery and recycling
of the materials they contain and reduce the impact on human health and the
environment. The crossed-out “wheeled bin” symbol on the product reminds you
of your obligation, that when you dispose of the appliance it must be
separately collected. Consumers should contact their local authority or
retailer for information concerning the correct disposal of their old
appliances.
This product is in compliance with the essential requirements and other
relevant provisions of EMC directive 2014/30/EU. The device was approved for
use in EU countries, therefore, bear the CE. All necessary documentation is
available at the importer’s address.
Changes in technical parameters, properties, printing errors in the
instruction manual reserved.
Importer Address:
Bibetus s.r.o.
Loosova 262/1
Brno 638 00
Czech republic
E-mail: info@bibetus.cz
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>