1 Before first use

1.1 Why humidify the air?

Stay in heated rooms can be not only unpleasant, but also insanitary. One of the main reason is low humidity. Optimal humidity is between 45% and 55%, while in many of our homes in winter humidity drops below 20%.

What does low humidity causes? Dust particles, bacteria, viruses, dust mite faces are collected by nasal mucosa are exhaled back in normal state, but due to dry air these particles get into the lungs and reduce natural defence. This actions overload the immune system and irritate the mucous membranes, cough, cracked lips and it is very close to any kind of disease.

Ultrasonic humidifiers Ariba are ideal for apartments, offices, everywhere where low humidity can cause health problems for people. Ultrasound produced vapor is harmless to health. The biggest advantage of the ultrasonic humidifiers is high performance together with low energy consumption.

1.2 Principle of ultrasonic humidifier

Ultrasonic Humidifier use the ultrasonic high-frequency oscillator to break up water into tiny water particles with the diameter of about 1-5µm.The ventilation system blows out this water into the dry air where they evaporate to give the required humidity. The clearly visible smooth and even fog can be seen out of the unit.

1.3 Security instructions
  • Always read the user guide instructions carefully before using the
  • Keep this User’s Manual for future
  • After unpacking, make sure that humidifier wasn’t damaged during transport. If you find any damage, contact your dealer as soon as possible. We recommend you keep the packaging for possible future use .
  • Before first use check that the device parameters (electric voltage, etc.) correspond to local
  • Always put the humidifier on a hard, flat horizontal surface, at least 15cm from the walls and away from any source of heat such as burners, radiators etc. The humidifier cannot operate on a surface that is not
  • Keep the humidifier out of reach of Do not permit children to play with it.
  • Before using the humidifier, unwind the cord and check if it is not Do not use it if the cord is damaged.
  • Do not plug or unplug the humidifier with wet
  • Never disassemble the basic
  • Never operate the humidifier with a defective plug or cord, or after a breakdown or damage of any kind. In these cases, return the appliance to the nearest approved dealer/repairer for verification and any necessary repairs or adjustments.
  • Do not use additives such as perfumes, essences,
  • Do not shake the This could spill water into the base unit and affect its operation.
  • Do not leave the humidifier in the sun for a long
  • If an unusual odour occurs during normal use, turn off the appliance, unplug it and have it verified by qualified personnel.
  • Unplug the humidifier before cleaning or if removing the tank.
  • Never touch the water or the immersed components when the appliance is in
  • Never turn on the humidifier when there is no water in the
  • Never scratch the
  • To prevent any damage to the components, do not allow water to splash inside the base
  • Never wash the entire unit with water; do not immerse it.
  • The ultrasonic humidifier should be cleaned To do this, refer to the cleaning instructions in this manual and respect them.
  • Do not use the humidifier if the air in the room is already sufficiently moist (more than 50% relative humidity). Excessive humidity gives rise to condensation on cold surfaces or walls in the
  • Device is only for indoor
  • This device is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they are supervised or have the person responsible for their safety.
  • Clean and dry device according to the following guidelines before storage. Don’t store device when the water is Store device on dry and cool place, out of reach of children.

2 Description

2.1 Technical specifications

Model: SPS-706
Evaporation rate: 250 ml/h
Water tank capacity: 5 litrů
Noise level: < 35 dB (A)
Power supply: 220-240 V
Frequency: 50/60 Hz
Total power: 30W
Dimensions: 26 x 20 x 32 cm

2.2 Humidifier’s diagram
  1. – output jet
  2. – water tank handle
  3. – water tank
  4. – inlet of water tank
  5. – water filter
  6. – water tank cover
  7. – power control LED
  8. – security sensor
  9. – transducer
  10. – bottom part (base)
  11.  – main power switch
  12.  – light on button
2.3  Features

Low energy consumption, save 85-90 percent of electricity of normal stream humidifier.
Automatic control to humidity level, lack-water security protection.
Ceramic filter to soften and purify the water.
Releases abundant anion, promotes cellular metabolism, increases vitality and appetite, purifies blood and soothes one’s nerve.
Easy to refill water into the water tank
Increase and regulate relative humidity of the room air.
Eliminate electrostatic charges.
Prevent different diseases.
Keep your appearance fit and protect your skin.
Night light.

 3 How to use

Before first use, allow the device to adjust room temperature at least half an hour. The device is recommended for use in the temperature range 5-40 °C and relative humidity less than 80%. Remove the water tank, unscrew the cover from the bottom of the tank and fill the tank with clean water (water temperature should be under 40°C). After filling water tank close it.

Check the bottom part of the humidifier and make sure that this part is clean. Carefully place the water tank on the base and wait a few seconds before the water gets into the basin. Plug the cord into the outlet (NEVER SWITCH ON DEVICE WITHOUT WATER IN BASIN) and power on humidifier – turn main power switch clockwise. Power control LED should light on.

There is main power switch and light button on front side. Light button activates/deactivates night light – useful for children. Use main power switch to control mist output and switch on/off humidifier.

4 Troubleshooting

Trouble Possible reason Solution
Power lamp off, humidifier does not work No power supply Connect power

supply, switch on
Power lamp on, no mist outlet with wind| No water in water tank| Fill water into water tank
Abnormal smell mist| New unit| Take out water tank, open cover, let it stay 12 hours in cool position
Dirty water or long time staying water| Cleaning water tank, fill in clear water
Power lamp on, unit doesn’t work| Security switch is too slight| Make the switch tight
Water tank is broken| Contact authorized service
Mist fog is too small| Too much scum in the water basin| Clean transducer
Water is too dirty or water kept too long in the tank| Clean water tank, change to fresh clear water
Abnormal noise| Resonant in water tank when water is too less| Fill water into water tank
Unit is on an unstable surface| Move the unit to a stable flat surface
Mist coming out from around nozzle| There are apertures between the nozzle and water tank| Dip the nozzle in water for a while and then fix it to the socket on water tank

As faulty is not considered the following :

  • If use too hard water in humidifier white coating of sediment may appear in the room. This is not Please use soft water.
  • Gurgle of water which can be heard close to humidifier is a normal
  • The device operates quietly, but not completely Noise less than 35 db is not considered as defect.

WARNING!

Should up mentioned solutions do not work please contact the manufacturer or agent. Do never arbitrarily disassemble, repair or restructure the apparatus.

 5 Maintenance

In case when the water is hard which means water contains too much calcium and magnesium, they can cause “white powder” problem and give heavy scum on the surface of water basin, transducer and inner surface of the water tank. Scum on the surface of transducer will make the unit work improperly.

We recommend:

  1. Use cold boiled water or distilled
  2. Clean the transducer, water tank and basin unit every
  3. Change the water in water tank more often to keep it
  4. Clean the whole unit, and make sure to keep all parts of the unit dry completely when the unit is not in use.

How to clean the transducer:

  1. Put 5-10 drops of vinegar on the surface of the transducer, wait for 2-5
  2. Brush out the scum on the
  3. Rinse the transducer with clean
  4. Never use sharp and solid objects for cleaning of transducer

How to clean the basin unit:

  1. Clean the water basin with soft cloth and the vinegar if there is scum in it
  2. If the scum is covered on the security switch, drop the vinegar on the scum and clean it out with the
  3. Rinse the water basin with clean

How to clean water filter:

  • Take the filter system away from the tank
  • Put the filter system into the white vinegar for about 10
  • Take the filter system away from the white vinegar; shake for several times, clean it with clear water.

How to replace water filter:

  1. Take the filter system away from the tank
  2. Fix new water
  3. Replacement is

If you don’t plan to use humidifier longer time remove the water filter and let it dry thoroughly. Then wrap it in protective packaging and keep it dry and dark place.

 6 Disposal of the device (environment)

At the end of the product lifecycle, you should not throw this product into the normal household garbage but bring the product to a collection point for the recycling of electrical and electronic equipment’s. The symbol on the product, user guide and/or box indicate this. Some of the product materials can be re-used if you bring them to a recycling point. By reusing some parts or raw materials from used products you make an important contribution to the protection of the environment. Please contact your local authorities in case you need more information on the collection points in your area.

This product is in compliance with the essential requirements and other relevant provisions of Directive 89/336/EEC. The device was approved for use in EU countries, therefore, bear the CE. All necessary documentation is available at the importer address.

Changes in technical parameters, properties, printing errors in the instruction manual reserved. Importer address: