Minoston MP22W Outdoor Smart Plug WiFi Outlet Heavy Duty Plug-in Outlet User Manual
- June 6, 2024
- Minoston
Table of Contents
- Minoston MP22W Outdoor Smart Plug WiFi Outlet Heavy Duty Plug-in Outlet
- SPECIFICATIONS
- Introduction:
- Key Features:
- Product Overview:
- Key function description
- QR CODE
- Command Class
- Z-Wave™ Configuration Parameters
- Support for Association Groups
- FCC Caution:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Minoston MP22W Outdoor Smart Plug WiFi Outlet Heavy Duty Plug-in Outlet
WARRANTY
Evalogik Products warrants this product to be free from manufacturing defects for a period of two years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which vary from state to state. if the unit should prove defective within the warranty period.
SPECIFICATIONS
- Model: MP22ZD
- Power: 120 VAC, 60 Hz.
- Signal (Frequency): 908.42 MHZ.
- Maximum load for outlet 500W Resistive
- Maximum load for the Z-Wave™ controlled outlet:
- Range: Up to 100 feet line of sight between the Wireless ControlROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION
and the closest Z-Wave™ receiver module. Operating Temperature Range: 32-104° F (0-40° C) Specifications subject to change without notice due to continuing product improvement Website:www.nie-tech.com
WARNING
- RISK OF FIRE
- RISK OF ELECTRICAL SHOCK
- RISK OF BURNS
- CONTROLLING APPLIANCES:
- EXERCISE EXTREME CAUTION WHEN USING Z-Wave™ DEVICES TO CONTROL APPLIANCES. OPERATION OF THE Z-Wave™ DEVICE MAY BE IN A DIFFERENT
MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave™ DEVICES MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING. DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
THE FOLLOWING:
DO NOT USE Z-Wave™ DEVICES TO CONTROL ELECTRIC HEATERS OR ANY OTHER APPLIANCES
WHICH MAY PRESENTA HAZARDOUS CONDITION DUE TO UNATTENDED OR mUNINTENTIONAL OR
AUTOMATIC POWER ON CONTROL.
Introduction:
This product can be operated in any Z-Wave™ network with other Z-Wave Plus™
certified devices from other manufacturers. All non-battery operated nodes
within the network will act as repeaters regardless of vendor to increase
reliability of the network. Each module is designed to act as a repeater,which
will re-transmit a radio frequency (RF) signal by routing the signal around
obstacles and radio dead spots to ensure that the signal is received at its
intended destination.
MP22ZD is a security enabled Z-Wave Plus™ device. A security Enabled Z-Wave
Plus™ Controller must be used in order to fully utilize the product. The
Device Type of the MP22ZD is on/off power switch. The Role Type of the MP22ZD
is Always On Slave Role Type
Key Features:
- Remote ON/OFF control via the Z-Wave™ controller
- Manual ON/OFF control with the front panel push button
- Support Association Group and Auto Report switch status
- Support firmware upgrades via Over-the-air (need Gateways support) —Support Scenes
Product Overview:
- AC plug
Z-Wave™ controlled outlet
ON/OFF/PROG Push button/ Status LED
Key function description
-
Function 1:
Press the button to turn the output ON or OFF -
Function 2:
quickly press 3x Button: ADD(inclusion) (only if switch is not included in network)quickly press 3x Button:Remove( exclusion) -
Function 3:
Press click Z-Wave button 3 times quickly, and hold for at least 10 seconds at the third time to restore the device to the factory
(Node: Please use this procedure only when the network primary controller is missing or otherwise inoperable.) -
Function 4:
Tap A(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Adding Your Device To A Hub
The device support two methods of inclusion,When using a Z-Wave Plus™ certified controller choose Network Wide Inclusion or SmartStart, Network Wide Inclusion To A Z-Wave™ Network
- Refer to your primary controller instructions to process the inclusion / exclusion setup procedure
- When prompted by your primary controller, click the button three times in one second.
The device is compatible with SmartStart SmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave™ QR Code found on the top of the outlet or the back of the box with a controller providing SmartStart inclusion.No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on and in the network vicinity.
QR CODE
the QR code are sticked to the side of the case,DSK is included in the QR code. DSK The DSK code can be found on the DSK label which is attached on the packaging box.
Command Class
Z-Wave™ Configuration Parameters
You may use the below configuration parameters to change settings of the corresponding functionality. 2:Status LED Configuration
Status LED Configuration
- Paramter No: 2(0x02) Size:1 Byte
- Value: 00(default) Output and the LED are in the different state.
- Value: 01 Output and the LED are in the same state.
- Value: 02 LED Always OFF
- Value: 03 LED Always ON
Auto Turn-Off Timer
- Paramter No: 3(0x03), Size=4,
- Values:0 (minutes) default;
- Values: 1 – 65535 (minutes);
Auto Turn-Off Timer
- Paramter No: 5(0x05), Size=4,
- Values:0 (minutes) default;
- Values: 1 – 65535 (minutes);
Restores state after power failure
- Paramter No: 8(0x08) Size:1 Byte
- Value: 00 Output OFF.
- Value: 01 Output ON.
- Value: 02 (default) The state before a power outage.
Ramp rate(Local Button + Z-Wave™)
- Paramter No: 9(0x09), Size=1,Default =1
- Value=1 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
- Value=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
- Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s
Multilevel minimum value can be set(Local Button)
- Paramter No: 10(0x0A), Size=1,Default =1
- Value=0 disable
- Value=1
- Value=2
- Value=99
Multilevel maximum value can be set(Local Button)
- Paramter No: 11(0x0B), Size=1,Default =99
- Value=0 disable
- Value=1
- Value=2
Double Tap Behavior—when switch is off and quickly press button 2 times, switch turns on to x brightness
- Paramter No: 12(0x0C), Size=1,Default =0
- Value=0 enable double tap to full brightness (99)
- Value=1 custom value set in parameter 18
- Value=2 enable double tap to maximum brightness (turn on to the value relate with parameter 11)
- Value=3 disable double tap to full brightness
Enable or Disable local / Z-Wave™ control
- Paramter No: 15(0x0F) Size:1 ,Default =1
- Value: 00 disable
- (when paddle pressed switch will not turn light on or off BUT it will still control the light via Z-Wave™ and
- it will change LED indicator status and on/off/multilevel status when paddle is pressed)
- Value: 01 enable (normal operation like now)
- Value: 02 disable local and Z-Wave™ control
- (LED and on/off status will still change if paddle pressed) >>
- make sure that status is still reported and LED indicator changes when Z-Wave™ control is disabled
dimmer speed (only for local press & hold)
- Paramter No: 16(0x10), Size=1,Default =5
- Value=1 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
- Value=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
- Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s
Association reports
- Paramter No: 20(0x14) Size:1 ,Default =2
- Value: 00 Z-Wave™ control:Multilevel report (without each level,just final level)
- Manual control (short press): Basic report(without each level,just final level)
- Manual control(long press & relay enable): Basic report(without each level,just final level)
- Manual control(long press & relay disable): Multilevel report (each level will be reported)
- Value: 01 Z-Wave™ control:Multilevel report (without each level,just final level)
- Manual control (short press): Basic report(without each level,just final level)
- Manual control(long press & relay enable OR disable): Basic report
- Value: 02 Z-Wave™ control:Multilevel report (without each level, just final level)
- Manual control (short press): Multilevel report (without each level, just final level)
- Manual control (long press & relay enable): Multilevel report (without each level, just final level)
- Manual control (long press & relay disable): Multilevel report (each level will be reported)
Disabled Relay Behavior
- Paramter No: 21(0x15) Size:1 ,Default =0
- Value: 00 report on/off and multilevel status when paddle is pressed and change LED indicator status and
- Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20
- Value: 01 DON’t report on/off or multilevel status or and change LED indicator status when paddle is pressed and
- Parameter 15 is set to value 0 or 2 (output control disabled).
Night Mode Brightness Level—Set the level of brightness the dimmer will turn on to when off and held Button for 2 seconds
- Paramter No: 22(0x16) Size:1 ,Default =0
- Value: 00 disable function
- Value: 01-99
LED Indicator Color
- Paramter No: 23(0x17), Size=1,Default =1
- Value=0 White
- Value=1 Blue
- Value=2 Green
- Value=3 Red
LED Indicator Brightness
- Paramter No: 26(0x18), Size=1,Default =1
- Value=0 Bright (100%)
- Value=1 Medium (60%)
- Value=2 Low (30%)
Support for Association Groups
MP22ZD supports 3 association groups. Group 1 supports 1 node ID,Group 2 and Group 3 Supports maximum of 5 node ID’s Association group_1:Z-Wave™ Plus Lifeline Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for MP22ZD Status change report,
MP22ZD will trigger AUTO report function if the Switch status had been changed. (ex.Switch Multilevel Report/Indicator Report/Central Scene Notification/ Device Reset Locally Notification) Association group_2:basic set command on/off control When the output of the MP22ZD is changed, On (0xFF) or Off (0x00). The MP22ZD will automatically send out a related basic set command. On (0xFF) or Off (0x00) to its associated group. Association group_3:basic set command on/off control When the output of the MP22ZD is changed, On (0xFF) or Off (0x00). The MP22ZD will automatically send out a related basic set command. On (0xFF) or Off (0x00) to its associated group.
Restoring Factory Defaults
MP22ZD is removed from the network and will be restored to the factory setting All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network. Manual Reset:Press click Z-Wave button 3 times quickly, and hold for at least 10 seconds at the third time to restore the device to the factory Remark : All the setting and data will be permanently deleted. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
FCC Caution:
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment. This
device complies with Part 15 of the FCC Rules. Operation is subject to the
following two
conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may caus harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.Consult the dealer or an experienced radio/TV technician for help.This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject
to the following two conditions:
- this device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device.
DECLARATION DE CONFORMITE D’INDUSTRIE CANADA
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>