mrSafe AP-100 Air Purifier User Manual
- June 6, 2024
- mrSafe
Table of Contents
mrSafe AP-100 Air Purifier
PARTS & FUNCTIONS
- Air outlet
- Handle
- Air inlet
- High speed indication light
- Low speed indication light
- Sleep mode indication light
- Power/speed button
- Power adapter socket
INSTALLATION
The air purifier has a filter installed. To remove and replace the filter, please follow these steps:
- Place the air purifier upside down.
- Rotate the bottom part of the device counter-clockwise and take off the cover.
- Take out the filter from the inside of the air purifier.
- Take the replacement filter and remove the plastic bag.
- Install the replacement filter without the plastic bag into the air purifier.
- Put the cover back on the device by rotating it clockwise.
Important:
- When replacing the filter, please turn off the power first. Do not operate with the filter removed (no dust removal effect, and the dust that is inhaled may cause equipment failure).
- Place the filter in a ventilated place so that the harmful gases and bacteria on the surface of the filter can be volatilized. Do not expose it to excessive sunlight.
- Do not wash the filter with water.
OPERATION
- After plugging in the power, press the Power button (7) once to start the air purifier. The default setting is Sleep mode. The corresponding indicator light will light.
- Press the Power button (7) a second time to activate Low speed mode. The low speed indicator light (5) will light.
- Press the Power button (7) a third time to activate High speed mode. The high speed indicator light (4) will light.
- Press the Power button (7) a fourth time to shut down the device.
SPEED
Press the Power/Speed button (7) to change the working speed of the air
purifier: Sleep mode – low speed – high speed. The selected speed mode is
indicated by the corresponding indication lights. Note : Sleep mode means
that the device operates in low noise mode.
ATMOSPHERE LIGHT
Press the Power/Speed button (7) for 3 seconds to turn on the atmosphere
light. Press again for 3 seconds to turn off the light.
FILTER REPLACEMENT
The HEPA + activated carbon composite filter inside the air purifier needs to
be replaced every 6 months (4500 hours). Replace the filter as described
above. Note: Depending on the place and the method of use (for example,
households with a large number of smokers or areas with severe air pollution),
the filter replacement cycle may be shortened. If the filtration effect is not
obvious, replace the filter in time.
SAFETY INSTRUCTIONS
- Do not place in the following places:
- In direct sunlight or facing the air outlet and heated places.
- Close to devices such as TVs and radios (which may cause image distortion and noise). Please place it at a distance of 1m or more.
- In order to effectively circulate the air in the room, place the product about 30 cm or more from the left and right sides of the wall, furniture, curtains, etc.
- Do not place objects on the unit.
- Do not block the air inlet and outlet, for example, do not place objects on the air outlet or in front of the air inlet. G
- Do not pull on the power cord as it may cause a short circuit or damage to the inside of the power cord, resulting in fire or electric shock.
- Do not damage the power cord or plug, and do not cut, excessively twist, pull, or twist the power cord. If the power cord is damaged, it must be replaced by the manufacturer, service department or a professional to avoid danger. Non-professionals are prohibited from disassembling the machine to avoid the risk of electric shock.
- Do not use power supplies, universal sockets or connected devices that exceed the rated value. Using a universal outlet that exceeds the rated value or connecting the power supply may cause the power cord to overheat and cause a fire.
- Do not touch the power plug with wet hands, which may result in electric shock.
- Do not put your fingers or metal objects into the gap of the air outlet, otherwise it may cause electric shock or injury. Do not allow water, flammable detergents or other liquids to enter the product to avoid electric shock or fire.
- Do not use this product in a wet or hot environment such as a bathroom, toilet or kitchen
- insecticides. Chemical residues may accumulate in the machine and then be released from the air outlet to endanger your health.
SUPPORT
For more information, spare parts, technical questions and return requests
concerning this product, you should contact
support@mrsafe.eu.
GUARANTEE
Copyright © Mr Safe. Mr Safe® is a registered trademark of TE-Group NV. The Mr
Safe® brand stands for superior product quality and outstanding customer
service. That is why Mr Safe® warrants this product against all defects in
material and workmanship for a period of two (2) years from the date of
original purchase of the product. The conditions of this guarantee and the
extent of responsibility of Mr Safe® under this guarantee can be downloaded
from our website: www.mrsafe.eu
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>