Prior to Installation

  • All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated and receive regular maintenance in accordance with these instructions.
  • This product needs to be installed in accordance with, and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and current by-laws.
  • For full Installation Requirements & Notes (IRN) please visit wras.co.uk/directory.
  • Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance.
  • Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder etc.
  • This product must not be modified in any way as this will invalidate the guarantee.
  • Full access must be made available for future maintenance/servicing purposes.
  • Before drilling into walls, check that there are no hidden electrical wires, cables or water supply pipes. This can be checked with the aid of an electronic detector.

If power tools are used do not forget to:

  • Wear eye protection
  • Unplug equipment after use

If in doubt, contact a registered plumber or your Local Water Authority or the Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791

Cavity Dimensions (mm)

Pack Contents

Installation

  1. Prepare the pipework. Create the rear access point in the back of the wall cavity.

  2. Screw the shroud onto the valve.

  3. Install suitable batons (if required) onto the rear cavity. Mark the position of the valve and drill and plug holes to suit.

  4. Secure the valve using the screws supplied (solid walls only) or a suitable alternative.

  5. Plumb the outlet pipe from your chosen shower into the inlet connection on the diverter. Ensure that olives are fitted.

  6. Plumb your chosen outlets into the remaining connections on the diverter.
    Turn on the water supply and check the valve for any leaks.

  7. Draw around the concealing plate as a template, measuring in by 10mm to give clearance. Finish the wall surface. Using a silicon sealant, push on the concealing plate and hold firmly until set.

  8. Fit the handle ensuring the spline adaptor is in place.

BRISTAN PM3WDIVC Prism Diverter fig 5 BRISTAN
PM3WDIVC Prism Diverter fig 6

General Cleaning

Bristan products are made from premium materials, with hand polishing and electroplated finishes.
Your taps or shower should be regularly cleaned with warm water, a mild pH- neutral liquid soap, and polished with a soft cloth. Any residues from soap, toiletries etc. should be rinsed off straight after use.
Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool or anything similar.
Some surfaces such as nickel and pewter may be affected by the dye found in some cloths, so it is also important to avoid hanging cloths on spouts.

Spare Parts

To replace any spare parts for your shower why not scan the below QR Code and search for your product.

Operation

BRISTAN PM3WDIVC Prism Diverter fig 7

Maintenance – Cartridge Cleaning

BRISTAN PM3WDIVC Prism Diverter fig 8

Troubleshooting

Troubleshooting|
---|---
Symptom| Cause(s)| Remedy

No flow or low flow rate

| Partially closed isolation valve.| Open isolation valve.
Instantaneous water heater cycles on and off as flow rate or pressure is too low.| Increase water flow rate or pressure through system.
Head of water is below the minimum distance required.| Refer to your the Specification for the minimum working pressure/distance required.
Hot or cold water being drawn off elsewhere causing pressure changes or instantaneous boiler temperature changes.|

Do not use other water outlets when using the taps.

Airlock or partial blockage in the supply pipework or hoses.| Flush through pipework to ensure removal of debris and any airlocks.

Water supply failure

| Investigate water supply. Check your plumbing and heating systems for any faults.

Water dripping from shower

| This is normal for a short time after using the shower.| This is caused by residual water tension, the build up of water in the shower.
If water continues to drip,

possibly due to the ceramic disc valves/cartridge

| Refer to the Maintenance section or visit www.youtube.com/BristanTV to watch the procedure.

Shower does not turn on

| Closed isolation valve.| Open isolation valve.
Mains water supply turned off.| Turn on mains water supply.

At Bristan, we want to make things as easy as possible for our customers. That’s why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind.

To start your free guarantee simply scan the QR code and register your product. Alternatively visit www.bristan.com/register.

For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice.

For full guarantee terms and conditions visit www.bristan.com/guarantees.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BRISTAN User Manuals

Related Manuals