SALUS KL08RF24V Zigbee Network Wireless Wiring Centre User Manual
- June 6, 2024
- SALUS
Table of Contents
SALUS KL08RF24V Zigbee Network Wireless Wiring Centre
Wiring centre description
- Cartridge fuse 5 x 20 mm 12 A
- Power Supply
- Thermostat grouping status
- Network Status diode
- Pair button
- Reset button
- . Delay jumper
- INT/EXT antenna jumper
- NC/NO actuators jumper
- ZigBee network coordinator
- Terminals for actuators
- Pump control output
- Boiler control output
- CO terminal
- . Dew point sensor input (humidistat)
- Serial connector for the KL04RF 24V extension
- External antenna connector
RX10RF (optional) Additional, wireless device control module that can be used – for example – when we can’t use cable between the KL08RF 24V wiring centre and the boiler.
Introduction
The KL08RF 24V wireless wiring centre is a part of the iT600RF system. In
combination with the wireless thermostats from iT600RF series, KL08RF 24V
provides comfortable and reliable heating control. It is equipped with the
control outputs for the pump and boiler and has been designed to work with NC
or NO actuators.
In Offline mode, communication with the wireless thermostats from iT600RF
series must be done through the CO10RF co-ordinating unit, which is in the
package together with the wiring centre. To work in Online mode (via the SALUS
Smart Home app) KL08RF 24V must be connected to the Internet gateway UGE600.
In one ZigBee network (Online or Offline) up to 9 KL08RF 24V wiring centres
can be connected. KL08RF 24V increases ZigBee network range.
Product compliance
This product complies with the essential requirements and other relevant provisions of Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com.
Safety information
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect your device before cleaning it with a dry cloth. This accessory must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the city, country or state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
Technical information
Power supply: 24 V AC
Max load: 3 A
Inputs: CO terminal Dew point sensor (humidistat)
Outputs: Pump control Boiler control Terminals for actuators
Radio frequency: ZigBee 2,4 GHz
Dimensions [mm]: 355x83x67
1. Fuse
The mains fuse is located under the housing cover, at the main terminals and protects the wiring centre and devices powered by it. Use cartridge fuse-type 5 x 20 mm – nominal burn rate 12 A. To remove the fuse, lift the socket with a flat screwdriver and pull out the fuse.
Power Supply
The wiring centre is designed to be supplied with 24V ~, 50Hz voltage. Installation features:
- three-wire, with PE protective conductor,
- made in accordance with applicable regulations.
- The KL08RF 24V wiring centre has a built-in 230V /
- a voltage of 24V. A maximum of 24 actuators can be connected to the KL08RF 24V wiring centre.
Thermostat grouping status
This function is only available in Offline mode (together with CO10RF
coordinator) – it means MASTER thermostats will affect to SLAVE thermostats
within specific group, which is possible only when thermostats are paired with
one KL08RF wiring centre (optional + KL04RF) and have been assigned to gr. 1
or gr. 2.
Note: Within one group there may be only one MASTER thermostat (programmable)
and must be SLAVE thermostats (non-programmable).
How it works: If all thermostats of a given group will operate in automatic
mode, then each of the thermostats in a given group will work in the same way
as the MASTER of this group. For example, if the MASTER thermostat of Group 1
according to it’s programmed schedule maintains a comfort mode – all SLAVE
type thermostats from Group 1 will also maintain the comfort mode (the
temperature is set individually for every thermostat). Similarly, if the
MASTER thermostat is set to Party or Holiday mode – SLAVE thermostats in his
group will also work in these modes.
Network Status diode
- (LED diode is blinking) – it means wiring centre is not connected to the network, but it is ready for pairing with the coordinator (CO10RF) of the ZigBee network or the Internet gateway (UGE600)
- (LED is steady lit) – it means wiring centre is added to the ZigBee network and paired with CO10RF or UGE600
Pair button
Checking the address of the wiring centre in the Zigbee network. To check the address of the wiring centre in the ZigBee network (when using more than one) press the Pair button. The wiring centre number is indicated by the number of LEDs at the zones:
Reset button
is used to refresh the data, after moving jumpers 7,8 or 9. The Reset button does not remove the wiring centre from the ZigBee network.
Delay jumper
Boiler off delay time. Note: Pump (Pump output) and boiler (Boiler output) always starts 3 minutes after receiving the heating signal from any thermostats paired with wiring centre. Pump stops after 3 minutes, when the last thermostat stops sending demand for heat, while the heat source (Boiler) will turn off after the time set with the jumper. Jumper position change must be refreshed in the memory by pressing the Reset button (short press).
INT/EXT antenna jumper
There is an option to connect the 08RFA external antenna to the wiring centre. If you use an additional antenna, place the jumper in the EXT position. Jumper position change must be refreshed in the memory by pressing the Reset button (short press).
NC/NO actuators jumper
Select the type of the thermoelectric actuator connected to the wiring centre: NC – actuator normally closed NO – actuator normally opened Jumper position change must be refreshed in the memory by pressing the Reset button (short press).
ZigBee network coordinator
for Offline mode and it’s included with the wiring centre. CO10RF enables wireless control of all devices installed in one network. Within one network can be connected max 9 wiring centres. It means that if in thenetwork there are more than one wiring centre, you can use one coordinator and put the remaining ones in a safe place.
Terminals for actuators
Wires of thermoelectric actuators should be plugged into self-locking connectors in appropriate zones. Three actuators can be connected directly to one zone. The current load of one zone is designed to operate up to 3 thermoelectric actuators with a power of 2 W. A maximum of 24 actuators can be connected to the KL08RF 24V wiring centre.
Pump control output
Pump output – this is a volt free output (COM / NO) that controls the circulation pump in the heating/cooling system. The output closes (pump starts) always after 3 minutes after receiving the heating / cooling signal from any of the thermostats paired with wiring centre. The output opens (pump stops) after 3 minutes when the last thermostat stops sending heat / cold demand.
Boiler control output
Boiler output – this is a volt free output (COM / NO) that controls the boiler in the heating system. The output closes and the boiler turns on but always after 3 minutes after receiving the heating signal from any of thermostats paired with wiring centre. The output opens and the boiler switches off when the last thermostat stops sending heat demand (after the time set on the Delay jumper).
**CO terminal (input)
**
Opened CO input contacts (Changeover) means that whole system works in the heating mode. Short circuit at the input CO will automatically switch the whole system to cooling mode (wiring centre and paired thermostats).
Dew point sensor input (humidistat)
Dew point sensor input is active only in cooling mode (with closed CO contacts). Shorting the contacts at the dew point sensor input (too high humidity) causes switching off all zones in the wiring centre and Pump control outputs.
Serial connector for the KL04RF 24V extension
It is used for communication between the KL08RF 24V wiring centre and the KL04RF 24V extension module. KL04RF 24V extension module increases functionality and expands support up to 12 zones.
External antenna connector
The external antenna connector 08RFA is located underneath the wiring centre under zones 7 and 8. After connecting an additional antenna, place the jumper in the EXT position.
MOUNTING
INSTALLATION
-
Connect the wiring centre to the 24 V AC power supply. The Network Status LED will blink.
-
Online/Offline
-
Identification of the wiring centre
To identify the wiring centre in the ZigBee network, follow the steps below: In Online mode (using the SALUS Smart Home app):
Factory reset
To restore the factory settings, press and hold the Pair button for 15
seconds. G1 and G2 diodes will turn red and go out.
Note: If you restore the factory settings of the wiring centre, all
paired devices will be removed from the ZigBee network – you will have to
synchronize them again.
Note: After restoring factory settings, to re-enter pairing mode, click
the “Reset” button.