SALUS PL06 Pump logic Module for KL06 Wiring Ventre User Manual
- June 6, 2024
- SALUS
Table of Contents
Pump logic module for KL06 wiring centre Model: PL06
Manual
Introduction
The PL06 module extends the functionality of the KL06 wiring centre. The Module is used to control the pump (or boiler) using volt-free NC/COM/ NO contacts. When any of the thermostats connected to the KL06 230V call for heat, COM/NO contacts are closed. COM/NO contacts are open when thermostats connected the wiring centre stop calling for heat.
Product Compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC 2014/30/EU, Low Voltage Directive LVD 2014/35/EU, RoHS directive 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com
Safety Information
Use in accordance with national and EU regulations. The device should be used for the purpose intended and kept in dry conditions. The product is for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations. Before carrying out any installation or connecting wires, make sure that the device is not connected to any power source. Installation must be carried out by a qualified person. Incorrect connection of the wires may cause damage to the wiring centre. The module must not be used in damp conditions or exposed to water.
Technical Information
Power Supply | from the KL06 wiring centre |
---|---|
Max load | 5 (2) A |
Output | NO/COM/NC relay |
Dimensions [mm] | 60 x 80 x 20 |
Serial Connector for PL06 and PL07 Modules
This provides communication between the KL06 wiring centre and the PL06
module. The KL06 wiring centre + the PL07 module increases the functionality
and also makes it possible to control a pump or boiler. The PL06 module is
powered by the wiring centre.
Jumpers Description
Jumpers 0-15 LN LN These are used to set in minutes the delay (overrun) time. Default setting is “0”. 0-15 values specify the time in minutes, e.g. when a jumper is set to “0” COM/NO output will turn off as soon as the thermostats stop calling for heat. If the jumper is set to the value “10”, the module will turn off 10 minutes after the thermostats stop calling for heat.
Jumpers P, 1, 2, 3, 4, 5, 6
These are used to select the zone which turns on the module. The default
setting is “P”. P – all zones start the module.
1, 2, 3, 4, 5, 6 – select the specific zone which turns on the module.
Wiring Diagrams
PUMP CONTROL
BOILER CONTROL
Boiler ON/OFF contacts (according to the boiler’s manual)
Installation of the Additional Module
Remove the top cover of the wiring centre.
Note: Before connecting the module, disconnect the main power from the
KL06 wiring centre.
Connect the module to the serial connector.
Make sure that all the wires are properly connected, mount top cover and power up the wiring centre – the green „Power” indicator LED will illuminate.
UK: tech@salus-tech.com
tel: +44 (0) 1226 323961
Head Office:
SALUS Controls Plc
Units 8-10 Northfield
Business Park
Forge Way, Parkgate, Rotherham
S60 1SD, United Kingdom
T: +44 (0) 1226 323961
E: sales@salus-tech.com
www.salus-controls.com
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc
reserve the right to change specification, design and materials of products
listed in this brochure without prior notice.
Issue Date: Mar 2020 V001
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>