RESMED S9 USB Adapter User Guide

June 6, 2024
ResMed

RESMED S9 USB Adapter User Guide

Resmed


Thank you for choosing a ResMed USB adapter

Intended Use

Used with ResMed devices, the USB adapters transmit patient therapy data between the device and Tx Link for sleep studies.
The Air10 USB adapter shown in illustration A is compatible with AirSense™ 10 /
AirCurve™ 10 / Lumis™ devices. The S9™ USB adapter shown in illustration B is compatible with S9 devices.
Before using the USB adapter, read the entire guide together with the device User Guide.
The USB adapter is intended to be used in a clinical environment only.
Note: Not all devices are available in all regions.

USB adapter at a glance

The USB adapter comprises the following elements:

  • USB adapter
  • USB cable.

Air10 USB adapter S9 USB adapter Refer to illustration A:

  1. Adapter connector
  2. Release button
  3. USB cable connector port.

Refer to illustration B:

S9 USB adapter

  1. USB cable connector port
  2. Release buttons
  3.  Adapter clip
  4. Adapter connector.

AirSense 10 / AirCurve 10 / Lumis

Refer to illustration C:
  1. SD card cover
  2. Air filter cover
  3. Adapter cover
  4. Adapter port.
Refer to illustration D:
  1. DC Power inlet
  2. Adapter clip socket
  3. Adapter port
  4. SD card slot
  5. Alarm (Bilevel alarmed devices only).
Software compatibility

Ensure the PC intended for use has the appropriate ResMed patient management software installed.

For a full list of compatible software refer to the Data Management Device Compatibility List on www.resmed.com.

Setting up

See illustration E or F:

  1. Ensure the device is disconnected from the power outlet.

  2. Connect the USB adapter to the device.

  3. Connect one end of the USB cable to the USB adapter and the other to the
    Tx Link or ResScan (S9 USB adapter only).

  4. Reconnect the device to the power outlet.
    You can now perform sleep studies, or download data (S9 USB adapter only). For more information, refer to the online software help. When the sleep studies or data download are complete, you can remove the USB adapter if required.
    Note: If you need help or to report an unexpected issue, contact a ResMed representative, ResMed Technical services or see www.resmed.com.

Removing the USB adapter

  1. Disconnect the device from the power outlet.
  2. Press the release button/s on the side of the USB adapter and pull gently to remove it from the device.

Cleaning and maintenance

  1. Disconnect the device from the power outlet and remove the USB adapter.
  2. Wipe the exterior of the USB adapter with a clean, dry cloth. The contacts do not require cleaning.

Technical specifications

Operating temperature +41°F to +95°F (+5°C to +35°C)
Operating humidity 10 to 95% non-condensing
Operating altitude Refer to your device User Guide for details.
Storage and transport temperature -4°F to 140°F (-20°C to +60°C)
Storage and transport humidity
Air10 5 to 95% non-condensing
S9 10 to 95% non-condensing

Symbols

The following symbols may appear on the USB adapter or packaging:

Caution/Warning. Read instructions before use. Manufacturer.
European Authorized Representative. LOT Batch code. Catalog number. Serial number. IP21 Protection against insertion of fingers and against vertically dripping water. IP22 Protected against finger sized objects and against dripping water when tilted up to 15 degrees from specified.

orientation. Humidity limitation. Temperature limitation. European
RoHS. China pollution control logo. Canadian Standards Association. Importer. Medical device.

Notes:

  • IP21 rating applies only to S9 USB adapter without USB cable attached.
  • IP22 rating applies only to Air10 USB adapter.

Environmental information

This device should be disposed of separately, not as unsorted municipal waste.
To dispose of your device, you should use appropriate collection, reuse and recycling systems available in your region. The use of these collection, reuse and recycling systems is designed to reduce pressure on natural resources and prevent hazardous substances from damaging the environment. If you need information on these disposal systems, please contact your local waste administration. The crossed-bin symbol invites you to use these disposal systems. If you require information on collection and disposal of your ResMed device please contact your ResMed office, local distributor or go to www.resmed.com/environment.

WARNING

Do not open or modify the USB adapter. The USB adapter is not designed to be serviced. There are no serviceable parts inside.

CAUTION

  • In the US, Federal law restricts this device to sale by or on the order of a physician
  • Only use the USB adapter as specified in this guide.
  • S9 USB adapters are specifically designed for use with ResMed S9 devices.
  • Air10 USB adapters are specifically designed for use with the ResMed AirSense 10 / AirCurve 10 / Lumis devices.
  • Do not use liquids to clean any part of the USB adapter.

Note: Any serious incident that has occured in relation to this device should be reported to ResMed and to the competent authority in your country.

Limited warranty

Please refer to your device User Guide.

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals