BougeRV HC24 Series PWM 24V Solar Charge Controller
Unpack
Note 1: Subject to modification. Actual products and accessories may differ in appearance.
Installation Notices
CAUTION:
INSTALLATION SHALL BE PERFORMED BY QUALIFIED PERSONNEL ONLY. INSTALLATION
SHALL BE IN ACCORDANCE WITH LOCAL PROCEDURES. IT’S NOT RECOMMENDED TO USE
WIPER WITHOUT A WASHER TANK. IT WILL CAUSE AN UNREPAIRABLE SCRATCH ON THE
GLASS.
PLEASE APPLY APPROPRIATE PROTECTION TO THE EYES WHEN INSTALLING IR MODULE ON
THE HOUSING.
Connectors
I/O Terminal Block Connection
I/O | Description |
---|---|
DO2 | Connect to tank water pump. |
DI2 | Wiper control, connects to IP camera’s DO for manually |
triggering washer.
RS485+|
Serial port to control IR, wiper and washer.
RS485-
DO+| +5V VCC
DI-| GND
DO1| IR LED status, connect with camera input to control IR cut
filter(default)
DI1| IR control by camera
TKH Security B.V. 2021 Vision 1.1 (20210218) HSG04 QSG
Connection diagram
RS485 Control
protocol | Baud rate | data bits | parity | stop bit |
---|---|---|---|---|
Pelco-D | 2400 | 8 | None | 1 |
Pelco-D command
Control | Pelco-D Command |
---|---|
Wiper On | Aux 1 On |
Wiper Off | Aux 1 Off |
Wiper and Washer On | Aux 2 On |
Wiper and Washer Off | Aux 2 Off |
IR Led Force On | Aux 3 On |
IR Led Force Off | Aux 3 Off |
HSG04-IR Wide | Zoom Wide |
HSG04-IR Tele | Zoom Tele |
HSG04-IR Stop | Zoom Stop |
Note 2: Once RS485 controls the IR Led, the IR mode will be in RS485 control. Please switch to “Light Sensor mode” by “FF 01 00 18 02 02 1D” Pelco-D command. The Light sensor at lamp will control the lamp by the lighting condition.
Complete HSG04 housing with accessories
Complete HSG04 housing with accessories
- Remove the metal cover from underneath the housing.
- 2. Install the HSG04-IR module and ensure the rubber gasket is in place.
- Adjust the IR distance by DIP switch.
Optional Accessory – HSG04-Wall Mount
- Fasten 2 screws to secure the intersection bracket at the bottom of the housing.
- Install the housing by pressing the spring mortise and hooking the bracket onto the groove in the spring mortise. Fasten the screws on the side.
- Connect the safety wire between wall mount and the housing.
- Fasten the wall mount to the mounting holes as indicated above.
Optional Accessory – HSG04-Pole Mount
HSG04-pole mount can be used with HSG04-wall as well as HSG04-power box. The different mounting holes are indicated below.
Optional Accessory – HSG04-Power Box
HSG04-Power box can be installed with HSG04-Wall as well as HSG04-Pole. The different mounting holes are indicated below.
Optional Accessory –Water Tank, WP10-10m-24Vac
Install the washer nozzle with a bracket to the side of the HSG04. Connect a piece of Ø8mm hose to the nozzle and use an Ø8-4 hose adapter as the bridge to the hose included in WP10-10m-24Vac. Secure each connections with a cable tie.