LIGHTINOVA CLIXX Magnetic Pendant Profile Light Instruction Manual

June 4, 2024
LIGHTINOVA

LIGHTINOVA logo

CLIXX
MAGNETIC
TRACK SYSTEM
INSTALLATION INSTRUCTIONSLIGHTINOVA CLIXX Magnetic Pendant Profile
Light - FIG24

LIGHTINOVA CLIXX Magnetic Pendant Profile Light| LIGHTINOVA CLIXX Magnetic Pendant Profile Light - FIG
---|---

LIGHTINOVA CLIXX Magnetic Pendant Profile Light - FIG1

  1. CONNECTING TRACKS (SURFACE AND SUSPENDED INSTALLATION)
    LIGHTINOVA CLIXX Magnetic Pendant Profile Light - FIG2

    Place track on a flat clean surface.| Remove the end caps with the included
    hex key or screwdriver.| Lift and remove the ‘decorative board*’ from
    the magnet.
    LIGHTINOVA CLIXX Magnetic Pendant Profile Light - FIG3
    Remove the magnet that supports the decorative board with a screwdriver.| Slide ‘pins’ into ‘powerplant’.
    CLIXX SLIM: 2 x pin-2 for all dimming typesCLIXX regular: pin-3  for TRIAC, 2 x pin-2 for
    1-10V and DALI.| Insert the ‘powerplant’ into the track, and make sure the pins connect correctly.

  • The ‘decorative plate’ should only be removed when connecting both sides of the track. If only 1 side of the track is connected, choose the side without the plate, which can be connected directly with ‘pins’.

LIGHTINOVA CLIXX Magnetic Pendant Profile Light - FIG4

The track is now prepared for electrical
connection.| Turn the track around.| Slide the ‘track connector’ into the first track.
LIGHTINOVA CLIXX Magnetic Pendant Profile Light - FIG5
Tighten the included screws until the track
connector is fixed into place.| Slide both the ‘track connector’ and ‘pins’ into
the second track, connecting tracks and
electrical circuit. Make sure the pins connect
with the terminal block.| Tighten the included screws until the track
the connector is fixed into place
2. CONNECTING CORNERS (ALL INSTALLATIONS
LIGHTINOVA CLIXX Magnetic Pendant Profile Light - FIG6

Slide ‘pins’ into board.
CLIXX SLIM: 2 x pin-2 for all dimming types
CLIXX regular: pin-3 for TRIAC, 2 x pin-2 for
1-10V and DALI.| Turn the track around.| Slide the ‘track connectors’ into the corner
profile and tighten screws until fixed.
LIGHTINOVA CLIXX Magnetic Pendant Profile Light - FIG7
Slide both the ‘track connector’ and ‘pins’ into
the second track, connecting tracks and
electrical circuit. Make sure the ‘pins’ connect
with the terminal block.| Tighten the included screws until the track
the connector is fixed into place.| Repeat these steps for the other end(s).
3. CONNECTING TRACK DRIVER BOX (ALL INSTALLATIONS)
LIGHTINOVA CLIXX Magnetic Pendant Profile Light - FIG8

Connect the cable to the driver box (L/N/PE). The
driver box is available for all installation types.| Attach the end cap to the driver box. Note that
the driver box is located at the start/end of the
track system or when connectable at both ends
in the middle.| Slide the ‘track connector’ into the ‘driver box’
and tighten screws until fixed.
LIGHTINOVA CLIXX Magnetic Pendant Profile Light - FIG9
Slide both the ‘track connector’ and ‘pins’
into the track, connecting tracks and electrical
circuits. Make sure the ‘pins’ connect with the
terminal block in the track.| Tighten the included screws until ‘track
connector’ is fixed into place.| The driver box is available for all installation
types. Note that the recessed driver box is
different. There is also a driver box available
that can be connected at both ends and
placed in the middle.
4. SURFACE INSTALLATION
LIGHTINOVA CLIXX Magnetic Pendant Profile Light -
FIG10

Decide the position of the track and mark the position of
mounting clips. Detailed instructions on the next
page.| Fix mounting clips to ceiling. Use plugs and
screws suitable for the specific ceiling type.
Make sure clips are aligned with the track.| Place the track over the mounting clips, leaving
the levers exposed.
LIGHTINOVA CLIXX Magnetic Pendant Profile Light -
FIG11
Turn the levers tight until the track is fixed into place.

Mounting of connected 2-meter tracks

LIGHTINOVA CLIXX Magnetic Pendant Profile Light -
FIG12

Each 2-meter track requires 2 mounting clips. The dimensions given above are indicative. Corner profiles and driver boxes are supported by the track connectors and do not require any mounting clips. Make sure to use a clip near where the tracks are connected if you notice that the track connector alone does not give enough support.
Mounting of connected 1-meter tracks

LIGHTINOVA CLIXX Magnetic Pendant Profile Light -
FIG13

A stand-alone 1-meter track requires 2 mounting clips. For connected tracks 1 mounting clip is sufficient. Corner profiles are supported by the track connectors and do not require any mounting clips. Corner profiles and driver boxes are supported by the track connectors and do not require any mounting clips. Make sure to use a clip near where the tracks are connected if you notice that the track connector alone does not give enough support.

SUSPENDED INSTALLATION

LIGHTINOVA CLIXX Magnetic Pendant Profile Light -
FIG14

Decide the position of the track and mark pendant
clips. 2 for 1m and 2m track.| Attach the ceiling rose (A) over the central box
and suspension brackets (B) to the ceiling.
Use plugs and screws that are suitable for the
specific ceiling type.| Place the tracks over the brackets. Connect the
power cable on top of the track (between the
sliders) or to the driver box or input terminal.
(See page 15)
LIGHTINOVA CLIXX Magnetic Pendant Profile Light -
FIG15
Turn the suspension brackets until the straight side
of the bracket is positioned under track exposing
the screw holes.| Fix suspension brackets into place with
included hex socket set.| – To shorten wire pull wire at the end
– To extend the wire push the top and pull the wire up

Mounting of connected 2-meter tracks

LIGHTINOVA CLIXX Magnetic Pendant Profile Light -
FIG16

A stand-alone 2-meter track requires 2 mounting clips. For connected tracks 1 bracket is sufficient. The dimensions given above are indicative. Corner profiles and driver boxes are supported by the track connectors and do not require any brackets. Make sure to use brackets near where the tracks are connected if you notice that the track connector alone does not give enough support.
Montage van aangesloten 1 meter tracks

LIGHTINOVA CLIXX Magnetic Pendant Profile Light -
FIG17

A stand-alone 1-meter track requires 2 suspension brackets. For connected tracks 1 bracket is sufficient. Corner profiles and driver boxes are supported by the track connectors and do not require any brackets. Make sure to use a bracket near where the tracks are connected if you notice that the track connector alone does not give enough support.

RECESSED INSTALLATION

LIGHTINOVA CLIXX Magnetic Pendant Profile Light -
FIG18

Place tracks on a flat clean surface.| Remove the end caps with the included hex key.| No pins are required for the connection of the
the electrical circuit between tracks, only use pins
to connect corner profiles.
LIGHTINOVA CLIXX Magnetic Pendant Profile Light -
FIG19
Insert the track into the cut-out (ceiling/wall).| Use drywall screws (preventing rust) to fix the
track in place. Wooden boards are recommended as
support. Make sure screws do not protrude and do not
distort the track.| Prepare the next track following the previous
steps.
LIGHTINOVA CLIXX Magnetic Pendant Profile Light -
FIG20

Connect cable(s) on top. 1 cable for TRIAC and
0-10V, 2 cables for DALI.| Tracks are now connected and fixed to the
ceiling. Always test the system with an LED
module before applying the plaster!| Apply the plaster.

When the plaster is completely dry, apply paint.

WIRING
TRIAC/ZIGBEE

LIGHTINOVA CLIXX Magnetic Pendant Profile Light -
FIG22

LIGHTINOVA CLIXX Magnetic Pendant Profile Light -
FIG23

Situation A, B, C
The driver is located inside the driver’s box. Only in the case of DALI 2 wires should be guided over the driver box to the track. L, N, and PE are automatically connected to the track through the driver box.
Situation D
The driver is located inside the ceiling box. Wires are connected on top of the track or through the input terminal.
Situation E, F, G
The driver is located elsewhere. Make sure the driver is accessible at all times. Wires are connected on top of the track or through the input terminal.

LIGHTINOVA logoLIGHTINOVA.COM

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals