beurer FB 50 Relax Foot Bath Instructions
- June 6, 2024
- Beurer
Table of Contents
beurer FB 50 Relax Foot Bath
Read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users and observe the information they contain.
WARNING
- The unit is only intended for domestic/private use, not for commercial use.
- This device may be used by children over the age of 8 and by people with reduced physical, sensory or mental skills or a lack of experience or knowledge, provided that they are supervised or have been instructed on how to use the device safely, and are fully aware of the consequent risks of use.
- Children must not play with the device.
- Cleaning and user maintenance must not be performed by children unless supervised.
- If the mains connection cable of this device is damaged, it must be disposed of. If it cannot be removed, the device must be disposed of.
- If water leaks from the appliance, the appliance should no longer be used.
- The device has a hot surface. Persons insensitive to heat must be careful when using the device.
- Under no circumstances should you open or repair the device yourself, as faultless functionality can no longer be guaranteed thereafter. Failure to adhere to this instruction will void the warranty.
Items included in the package
Check that the device packaging has not been tampered with and make sure that
all contents are present. Before use, ensure that there is no visible damage
to the device or accessories and that all packaging material has been removed.
If you have any doubts, do not use the device and contact your retailer or the
specified Customer Services address.
1 x Foothbad
1 x These operating instructions
Explanation of symbols
The following symbols are used in the operating instructions and on the type plate:
| WARNING
Warning of risks of injury or health hazards.
---|---
| CAUTION
Safety information about possible damage to appliance/accessories.
| Note
Important information.
| The device has double protective insulation and therefore complies with
protection class 2.
| Only use indoors
| Read the instructions for use
| Please dispose of the device in accordance with EC Directive – WEEE (Waste
Electrical and Electronic Equipment).
| Manufacturer
| CE labelling
This product satisfies the requirements of the applicable European and
national directives.
| The products demonstrably meet the requirements of the Technical Regulations
of the EAEU.
| Dispose of packaging in an environmentally friendly manner
| United Kingdom Conformity Assessed Mark
| Protection against splashes
Warnings and safety notes
Failure to observe the information provided below can lead to personal injury or material damage. Always pass on these instructions together with the appliance if you sell it or pass it on.
Note
- Keep children away from the packaging materials. Risk of suffocation.
- Before use, make sure that the device and accessories do not show any visible signs of damage. If you are in any doubt, do not use it and contact your dealer or a specified customer service address.
- If any fault or malfunction should occur during use, switch the unit off immediately and remove the plug from the mains socket. Never attempt to repair the unit yourself. Improper repairs can expose the user to considerable risks.
- Do not stretch, twist or kink the power cord. Do not stick in any pins, needles or sharp objects.
- Do not position the power cord on or pull it over sharp or pointed objects.
- Insert the plug into a socket that is protected from moisture, water and water spray.
- To fill the foot bath, it must not be placed in the shower, bath tub or wash basin.
- Do not open the case under any circumstances.
- If the device has been dropped or has suffered any other damage, it must no longer be used in order to avoid any risks.
- Repairs to electrical appliances must only be carried out by qualified persons. Incorrect repairs can lead to considerable danger for the user. In the event of repairs, please contact our customer service or an authorised dealer.
- The foot bath is suitable for feet up to shoe size 51/52.
- Warm foot baths with arnica, rosemary or sea salt extracts get the circulation going. Lukewarm foot baths with lavender or thyme have a relaxing effect and are a blessing for exhausted feet. Do not use any essential oils so as not to damage the foot bath.
Electric shock
WARNING
Just like any other electrical appliance, this footbath must be handled with
due care and attention in order to prevent the risk of electric shock.
For this reason, the device must only be operated as follows:
- With the mains voltage specified on the device only.
- Do not use the device if damage to the device itself or any of its accessories is evident.
- Never use the appliance during a thunderstorm.
In the event of a defect or malfunction, switch the device off immediately and disconnect it from the power supply. Never pull on the power cable or on the appliance in order to disconnect the plug from the mains outlet. Never hold or carry the device by the power cable. Keep the cables away from hot surfaces.
You must never connect the foot bath to the power supply when your feet are already in the water. If the device is damaged, this can lead to life- threatening electric shock.
Make sure that the plug and the power cord do not come into contact with water
or other liquids.
**** For this reason, the device must be operated as follows:
- only in dry inside rooms (e.g. never in the bathtub or sauna),
- only with dry hands, to avoid any risk.
Never immerse the device in water. Never try to retrieve the device if it falls into water. Disconnect the plug immediately from the mains outlet.
Fire hazard
WARNING
There is a risk of fire if the device is used incorrectly or if it is not used
according to these operating instructions.
For this reason, the massage device must only be operated as follows:
- Never use the device under covers, such as blankets or pillows.
- Never use the device in the vicinity of petrol or other easily flammable materials.
- Do not place on soft carpeting because the vents may be covered.
Handling
CAUTION
Switch the device off and disconnect the power supply after every use and
before every cleaning.
- Keep the device away from high temperatures.
- Never stand in the foot bath.
- The device must not be connected to the power supply while being filled.
- Always switch the foot bath off and remove the plug from the mains socket before moving it or cleaning it.
Intended use
This device is solely intended for the care of your feet.
WARNING
Do not use the footbath
- if you have a changes caused by disease or injury in the region of your foot (e.g. open wounds, warts, fungal infection),
- with animals,
- for longer than 60 minutes (danger of overheating) and allow it to cool for at least 15 minutes before using it again.
Never allow the footbath to operate unsupervised.
Children should be supervised to ensure that they do not use the device as a
toy.
You should consult your doctor before using the footbath
- if you are not sure whether the footbath is suitable for you,
- if you suffer from a serious illness or are recovering from an operation on one of your feet,
- you are fitted with a cardiac pacemaker, implant or other aid,
- if you have diabetes or thrombosis,
- if you have leg or foot conditions (e.g. varicose veins, vein inflammations),
- if you have pains of unclear origin.
The device is only intended for the purpose described in these operating instructions. The manufacturer cannot be held liable for damage occurring as a result of inappropriate or careless use.
Description of footbath
-
Spray guard
-
LED display
-
Infrared light
-
Removable pedicure attachments
a Massage attachment
b Brush
c Corn and callous remover -
Bubble bar
-
Level indicator
-
Massage roller
-
Massage-supporting footbed
-
Rubber feet (bottom of device)
-
Cord winder (bottom of device)
-
Narrow side
Display
- button
- Massage button
- Bubble button
- Timer button
- Temperature button
- LC display
Initial use
- Remove the packaging
- Check the device, power supply and cables for damage.
- Before plugging in the footbath fill it with warm water no higher than the level indicator (approx. 5 6 cm). The foot rest should, however, be completely covered with water.
- Now plug the device into the mains power supply.
- Route the cable safely so that there is no risk of anyone tripping over it.
- Place the foot bath on a firm and level surface.
Make yourself comfortable in a chair and place your feet on the foot rest and
apply slight pressure. Never stand up in the foot bath. The rubber feet on the
base of the unit prevent it from sliding.
Switch on the footbath by pressing the button and set the desired function.
Use
Vibration massage
Press the massage button (2) to switch on vibration massage. The footbath
starts to vibrate. Place the soles of your feet on the massage nubs and
increase or reduce the pressure for the desired massage effect.
Bubble massage
Press the bubble button (3) to feed air onto the bubble bar for a soothing
bubble massage.
Timer
You can set the desired time (20 60 minutes) with the timer function. Press
the timer button (4) to extend the time another 10 minutes. The timer is
factory-set to 20 minutes. The footbath switches off automatically once the
set time has expired. Maximum duration is 60 minutes. Allow the footbath to
cool for at least 15 minutes before using it again.
Temperature
The display shows the current water temperature. To change the temperature
press and hold the temperature button (5) until you have set the desired water
temperature (35, 38, 42, 45, 48 °C). The most pleasant temperature is in the
range 35 42 °C, the maximum temperature is 48 °C. The temperature is
factory-set to 35 °C.
Magnetic field and infrared
The footbath has 6 magnets and 8 infrared lights integrated into the bath.
They promote your circulation and stimulate the reflex zones.
Massage roller
You can experience a special massage effect by moving your feet back and forth
on the six massage rollers integrated into the bottom of the footbath. The
massage rollers can optionally be removed by pulling them firmly upwards.
Removable attachments
Place the desired attachment on the holder in the centre. Press the attachment
lightly down with your foot to activate the electric motor.
The brush attachment can be used to stimulate the reflex zones in the
soles of your feet
The massage attachment provides a soothing massage for your feet and
promotes the circulation.
The corn and callus remover is used to remove dead skin cells and
calluses.
The electric motor is protected from overheating and has a maximum load capacity. The motor stops if it is overloaded or overheated. It can be used again after cooling down.
Note
- Massage of a specific point on the sole of the foot may influence the corresponding organ of the body. However, we recommend studying relevant literature and asking your doctor before using point reflex zone massage to achieve the desired effect.
- The footbath can also be used without water.
After use pour the water out over the narrow side (11) of the footbath. Do not allow water to come into contact with the display.
Cleaning and maintenance
Cleaning
WARNING
- Switch off the device each time before cleaning.
- Clean the device using only the methods specified. Under no circumstances may liquid enter the device or accessories.
- Do not clean the device in a dishwasher.
- Do not use any abrasive cleaning products or hard brushes.
After use rinse the unit with tap water. The foot bath can be cleaned with a mild, non-foaming household cleaner, e.g. neutral vinegar. To dry the air lines, switch to the bubble setting without water for approx. 1 minute.
Note
- Do not allow water to penetrate the interior of the footbath.
Care
If you do not plan to use the device for a long period of time, we recommend
that you store it in the original packaging in a dry environment, ensuring it
is not weighed down by additional items.
Technical specifications
Supply | 220-240 V~; 50-60 Hz; 390 W |
---|---|
Dimensions: | 40.0 x 47.0 x 24.1 cm |
Weight: | approx. 5,2 kg |
Disposal
For environmental reasons, do not dispose of the device in the household waste at the end of its useful life. Dispose of the unit at a suitable local collection or recycling point. Dispose of the device in accordance with EC Directive - WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the local authorities responsible for waste disposal.
Warranty / service
Beurer GmbH, Söflinger Straße 218, 89077 Ulm, Germany (hereinafter referred to as “Beurer”) provides a warranty for this product, subject to the requirements below and to the extent described as follows.
The warranty conditions below shall not affect the seller’s statutory warranty obligations which ensue from the sales agreement with the buyer. The warranty shall apply without prejudice to any mandatory statutory provisions on liability.
Beurer guarantees the perfect functionality and completeness of this product.
The worldwide warranty period is 3 years, commencing from the purchase of the
new, unused product from the seller.
The warranty only applies to products purchased by the buyer as a consumer and
used exclusively for personal purposes in the context of domestic use. German
law shall apply.
During the warranty period, should this product prove to be incomplete or
defective in functionality in accordance with the following provisions, Beurer
shall carry out a repair or a replacement delivery free of charge, in
accordance with these warranty conditions.
If the buyer wishes to make a warranty claim, they should approach their local retailer in the first instance: see the attached “International Service” list of service addresses.
The buyer will then receive further information about the processing of the warranty claim, e.g. where they can send the product and what documentation is required.
A warranty claim shall only be considered if the buyer can provide Beurer, or
an authorised Beurer partner, with
- a copy of the invoice/purchase receipt, and
- the original product.
The following are explicitly excluded from this warranty:
- deterioration due to normal use or consumption of the product;
- accessories supplied with this product which are worn out or used up through proper use (e.g. batteries, rechargeable batteries, cuffs, seals, electrodes, light sources, attachments and nebuliser accessories);
- products that are used, cleaned, stored or maintained improperly and/or contrary to the provisions of the instructions for use, as well as products that have been opened, repaired or modified by the buyer or by a service centre not authorised by Beurer;
- damage that arises during transport between manufacturer and customer, or between service centre and customer; products purchased as seconds or as used goods;
- consequential damage arising from a fault in this product (however, in this case, claims may exist arising from product liability or other compulsory statutory liability provisions).
Repairs or an exchange in full do not extend the warranty period under any circumstances.
Subject to errors and changes
Beurer GmbH · Söflinger Str. 218 · 89077 Ulm, Germany · www.beurer.com www.beurer- healthguide.com · www.beurer- gesundheitsratgeber.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>