LIGHTING
SONAR RETRO BULB
INSTALLATION MANUAL
Tools Required:
Phillips Head No. 2 Screw Driver
IMPORTANT INFORMATION:
THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS OR NOT FOR EMERGENCY
LIGHTING. ENSURE LIGHT VOLTAGE MATCHES POWER SUPPLY VOLTAGE BEFORE CONNECTING
ANY LIGHT. MISMATCHED VOLTAGE MAY RESULT IN CATASTROPHIC FAILURE OF LIGHT
(VOIDING WARRANTY) AND/OR ELECTRICAL SHOCK AND SERIOUS BODILY HARM. PAL
LIGHTING ACCEPTS NO RESPONSIBILITY FOR INCORRECTLY INSTALLED LIGHTS.
- Ensure that the electrical system for your pool conforms with all the requirements of the National Electrical Code (NEC) and all relevant local codes and ordinances.
- This Underwater Light must be installed in accordance with the National Electrical Code by a Certified Electrician or a Qualified Pool Technician.
NOTE: No Bonding Terminal is required on the forming shell since the fixture is an all-plastic construction and complies with NEC article 680 Requirements.
To be certain that the pool or spa electrical system meets all applicable
requirements, the electrician should also consult the local building
department.
CANADIAN INSTALLATION
Be sure the electrical system of your pool conforms with the following
requirements of the Canadian Electrical Code (CEC), CSA C22.1, and all local
codes and ordinances. A licensed or certified electrician must install the
electrical system to meet or exceed those requirements before the light and
(fixture-housing) are installed. Failure to do so could result in death or
serious injury to the service technicians, pool users, or others due to
electrical shock.
BULB INSTALLATION
STEP 1
Turn the power off at the circuit breaker, then remove the existing light
fixture from the pool light niche and place it on the pool deck.
(DO NOT change light underwater)
STEP 2
While the fixture is out of the pool and the lens is off, Replace the
tensioning bulb or other fasteners if stripped or damaged. After inspection,
unscrew the old bulb and remove it
STEP 3
Check the light housing for damage. Inspect the rubber seal where the power
cord enters the housing for leaks or deterioration. Check the surface area
where the lens and rubber gasket sits for imperfections.
STEP 4
Make sure the inside of the light housing is completely dry.
STEP 5
Install PAL Bulb
STEP 6
It’s highly recommended to install a new lens gasket. If not sealed correctly
this could result in a leak that can damage them and cause serious injury or
death due to electrical shock. Install your new replacement gasket onto the
glass lens. Set the lens and cover plate on the light housing and secure by
tightening the screws and/or bulb, allowing the gasket to seal evenly.
STEP 7
Submerge the assembled light fixture in the water and visually check that air
bubbles are not escaping from the gasket area or at the power cord entrance.
If bubbles appear, immediately remove the light fixture from the water and re-
seat the gasket and lens. Continue the installation only if there are no air
leaks.
STEP 8
Turn power ON to the Bulb at the main panel. With the light ON, check for air
bubbles exiting the light fixture. Leave the Bulb on for 30 minutes and
continue to inspect. If there are no air bubbles, the fixture is watertight
and installation is complete.
REMOTE PROGRAMMING
Linking Lights to Zones:
Within 3 seconds of turning the light on, press desired zone number ‘I button’
3 times. Once linked, light(s) will flash 3 times.
Cloning Modes:
Within 3 seconds of turning light on, press and hold the ‘I button’ on the
required channel:
Channel 1 – PAL
Channel 2 – Jandy
Channel 3 – Hayward
Channel 4 – Pentair
Channel 5 – Astral
Unlinking from Zones:
Within 3 seconds of turning the light on, press the channel zone number’s ‘I
button’ that the light is currently linked to 5 times. Light will flash 9
times quickly to confirm it has been unlinked.
TERMS AND CONDITIONS
PAL PRODUCT WARRANTY DETAILS
The PAL product is guaranteed against defects in materials and/or workmanship,
under normal domestic use for (3) Three Years Except as otherwise provided for
by law, this guarantee becomes invalid if in the opinion of the Company the
product has been misused, abused, damaged in transit, incorrectly installed,
or connected to an electrical supply not corresponding with the products
specification or a non-approved PAL power supply. The Company is not
responsible for forwarding freight charges or losses in transit. If any part
of the product proves to be defective within the warranty period, the
defective part will be repaired or replaced, free of charge and at the
discretion of PAL Lighting. PAL Lighting shall not be liable for any loss of
profits or any consequential, indirect, or special loss, damage, or injury of
any kind whatsoever arising directly or indirectly from PAL Lighting products.
This limitation does not apply to any liability under the Australian or New
Zealand consumer legislation. PLEASE REGISTER YOUR PRODUCT WARRANTY DETAILS
ONLINE AT: www.pallighting.com/product-
registration OR You MUST
retain some proof of purchase to provide evidence of the DATE of the original
purchase.
https://pallighting.com/product/retro-lamp/
www.pallighting.com
info@pallighting.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>