ADA INSTRUMENTS А00545 Cube Line Laser User Manual
- June 6, 2024
- ADA INSTRUMENTS
Table of Contents
ADA INSTRUMENTS А00545 Cube Line Laser
OPERATING MANUAL
Line Laser
THE MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES (NOT HAVING AN IMPACT ON THE SPECIFICATIONS) TO THE DESIGN, COMPLETE SET WITHOUT GIVING PRIOR WARNING.
APPLICATION
Line laser ADA CUBE is designed to check the horizontal and vertical position
of the surfaces of the elements of building structures and also to transfer
the angle of inclination of the structural part to similar parts during
construction and installation works.
SPECIFICATIONS
- Leveling Range ………………………………….self-leveling, ±3°
- Working Range ………………………………….65 ft (20 m*)
- Laser Source ……………………………………. 2 x 620-690nm
- Accuracy …………………………………………. ±1/12 in at 30 ft (±2mm/10m)
- Beam divergence …………………………….. 0.5 mrad (full angle)
- Laser class ……………………………………….. 2
- Power Supply …………………………………… 3X1.5 V AAA
- Dimensions……………………………………… 2,6×2,6×2,6 in (65х65х65 mm)
- Operating temperature ………………….. 23º F to 113º F (-5°C +45°C)
- Weight ……………………………………………….0,51 lb (230 g)
LASER LINES
FEATURES
- exit opening for laser beam
- battery cover
- compensator switch
- tripod mount 1/4”
CHANGE OF BATTERIES
Open battery compartment. Insert batteries. Take care to correct polarity.
Close battery compartment.
ATTENTION: If you are not going to use instrument for a long time, take out batteries.
OPERATION
Place the line laser on the working surface or mount it on the tripod/pillar
or wall mount (comes with the instrument). Switch on the line laser: turn the
compensator switch (3) to the position “ON”. When enabled, the vertical and
horizontal plane projected constantly. Visual alarm (blinking line) and
audible signal indicate that the device was not installed within the
compensation range ± 3 º. To properly work align the unit in a horizontal
plane.
TO CHECK THE ACCURACY OF LINE LASER (SLOPE OF PLANE)
Set up the line laser between two walls, the distance is 5 m. Turn on the Line
Laser and mark the point of cross laser line on the wall. Set up the
instrument 0,5-0,7m away from the wall and make, as described above, the same
masrks. If the difference {a1-b2} and {b1-b2} is less then the value of
“accuracy” (see specifications), there is no need in calibration.
Example: when you check the accuracy of Line Laser the difference is
{a1-a2}=5 mm and {b1-b2}=7 mm. The instrument’s error: {b1-b2}-{a1-a2}=7-5=2
mm. Now you can compare this error with standard error. If the accuracy of
Line Laser isn’t corresponding with claimed accuracy, contact the authorized
service center.
TO CHECK THE ACCURACY OF HORIZONTAL BEAM
Choose a wall and set laser 5M away from the wall. Turn on the laser and cross
laser line is marked A on the wall. Find another point M on the hori-zontal
line, the distance is around 2.5m. Swivel the laser, and another cross point
of cross laser line is marked B. Please note the distance of B to A should be
5m. Measure the distance between M to cross laser lune, if the difference is
over 3mm, the laser is out of calibration, please contact with seller to
calibrate the laser.
TO CHECK PLUMB
Choose a wall and set laser 5m away from the wall. Mark point A on the wall,
please note the distance from point A to ground should be 3m. Hang a plumb
line from A point to ground and find a plumb point B on ground. turn on the
laser and make the vertical laser line meet the point B, along the vertical
laser line on the wall and measure the distance 3m from point B to another
point C. Point C must be on the vertical laser line, it means the height of C
point is 3m.
Measure the distance from point A to point C, if the distance is over 2 mm,
please, contact with seller to calibrate the laser.
CARE AND CLEANING
Please handle line laser with care. Clean with soft cloth only after any use.
If necessary damp cloth with some water. If instrument is wet clean and dry it
carefully. Pack it up only if it is perfectly dry. Transport in original
container/case only.
Note: During transport On/Off compensator lock (5) must be set to posi-
tion “OFF”. Disregard may lead to damage of compensator.
SPECIFIC REASONS FOR ERRONEOUS MEASURING RESULTS
- Measurements through glass or plastic windows;
- Dirty laser emitting window;
- After line laser has been dropped or hit. Please check the accuracy;
- Large fluctuation of temperature: if instrument will beused in cold areas after it has been stored in warm areas (or the other way round) please wait some minutes before carrying out measurements.
ELECTROMAGNETIC ACCEPTABILITY (EMC)
- It cannot be completely excluded that this instrument will disturb other instruments (e.g. navigation systems);
- will be disturbed by other instruments (e.g. intensive electromagnetic ra-diation nearby industrial facilities or radio transmitters).
LASER CLASS 2 WARNING LABEL ON THE LINE LASER
LASER CLASSIFICATION
The instrument is a laser class 2 laser product with power <1 mW and
wavelength 635 nm, corresponds to IEC 60825-1:2014. Laser is safety in
ordinary conditions of usage. Complies with 21 CFR 1040.10 and 1040.11 except
for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
SAFETY INSTRUCTIONS
- Please follow up on instructions given in the operators’ manual.
- Do not stare into beam. Laser beam can lead to eye injury (even from greater distances).
- Do not aim laser beam at persons or animals. The laser plane should be set up above eye level of persons. Use the instrument for measuring jobs only.
- Do not open instrument housing. Repairs should be carried out by authorized workshops only. Please contact your local dealer.
- Do not remove warning labels or safety instructions.
- Keep instruments away from children.
- Do not use instruments in explosive environment.
WARRANTY
This product is warranted by the manufacturer to the original purchaser to be free from defects in material and workmanship under normal use for a period of two (2) years from the date of purchase. During the warranty pe-riod, and upon proof of purchase, the product will be repaired or replaced (with the same or similar model at manufactures option), without charge for either parts of labour. In case of a defect please contact the dealer where you originally purchased this product. The warranty will not apply to this product if it has been misused, abused or altered. Without limiting the foregoing, leakage of the battery, bending or dropping the unit are presumed to be defects resulting from misuse or abuse.
EXCEPTIONS FROM RESPONSIBILITY
The user of this product is expected to follow the instructions given in op-
erators’ manual. Although all instruments left our warehouse in perfect
condition and adjustment the user is expected to carry out periodic checks of
the product’s accuracy and general performance. The manufacturer, or its
representatives, assumes no responsibility of results of a faulty or
intentional usage or misuse including any direct, indirect, consequential
damage, and loss of profits. The manufacturer, or its representatives, as-
sumes no responsibility for consequential damage, and loss of profits by any
disaster (earthquake, storm, flood …), fire, accident, or an act of a third
party and/or a usage in other than usual conditions.
The manufacturer, or its representatives, assumes no responsibility for any
damage, and loss of profits due to a change of data, loss of data and
interruption of business etc., caused by using the product or an unusable
product. The manufacturer, or its representatives, assumes no responsibility
for any damage, and loss of profits caused by usage other then ex-plained in
the users’ manual.
The manufacturer, or its representatives, assumes no responsibility for damage
caused by wrong movement or action due to connecting with other products.
WARRANTY DOESN’T EXTEND TO THE FOLLOWING CASES
- If the standard or serial product number will be changed, erased, removed or will be unreadable.
- Periodic maintenance, repair or changing parts as a result of their normal runout.
- All adaptations and modifications with the purpose of improvement and expansion of normal sphere of product application, mentioned in the service instruction, without tentative written agreement of the expert provider.
- Service by anyone other than an authorized service center.
- Damage to products or parts caused by misuse, including, without limitation, misapplication or negligence of the terms of service instruction.
- Power supply units, chargers, accessories, wearing parts.
- Products, damaged from mishandling, faulty adjustment, maintenance with low-quality and non-standard materials, presence of any liquids and foreign objects inside the product.
- Acts of God and/or actions of third persons.
- In case of unwarranted repair till the end of warranty period because of damages during the operation of the product, it’s a transportation and storing, warranty doesn’t resume.
WARRANTY CARD
Name and model of the product __
Serial number_Date of sale__
Name of commercial organization ____
stamp of commercial organization
Warranty period for the instrument exploitation is 24 months after the date of
original retail purchase.
During this warranty period the owner of the product has the right for free
repair of his instrument in case of manufacturing defects.
Warranty is valid only with original warranty card, fully and clear filled
(stamp or mark of thr seller is obligatory).
Technical examination of instruments for fault identification which is under
the warranty, is made only in the authorized service center.
In no event shall manufacturer be liable before the client for direct or
consequential damages, loss of profit or any other damage which occurs in the
result of the instrument outage.
The product is received in the state of operability, without any visible
damages, in full completeness. It is tested in my presence. I have no
complaints to the product quality. I am familiar with the conditions of
qarranty service and i agree.
purchaser signature _____
Before operating you should read service instruction!
If you have any questions about the warranty service and technical support
contact seller of this product
ADA International Group Ltd., No.6 Building, Hanjiang West Road #128,
Changzhou New District, Jiangsu, China
Made In China
References