ADA INSTRUMENTS ADA Cube Line Laser Level User Manual
- June 4, 2024
- ADA INSTRUMENTS
Table of Contents
ADA Cube Line Laser Level
INSTRUMENTS ADA Cube Line Laser Level
User Manual
Manufacturer: ADAINSTRUMENTS
Address: WWW.ADAINSTRUMENTS.COM
Kit
Cross-line laser, batteries, operating manual, universal mount (optional), a
tripod (optional), laser glasses (optional), сarrying case (optional). The
manufacturer may modify the complete set without notice.
Application
Cross Line Laser projects visible laser planes. It is used for the
determination of height, making horizontal and vertical planes.
Specification
Leveling Range | self-leveling, ±3° |
---|---|
Accuracy | ±2mm/10m |
Working Range | 20 m (depends on the illumination of the work area) |
Power Supply | 3xAAA Batteries Alkaline |
Laser Source | 2 x 635nm |
Operating temperature | -10°C to 45°C |
Laser class | 2 |
Dimensions | 65х65х65 mm |
Weight | 230 g |
Change of batteries
Open the battery compartment. Put in 3xAA Alkaline batteries. Take care to
correct polarity. Close the battery compartment.
ATTENTION: If you are not going to use the instrument for a long time,
take out the batteries.
Laser lines
Features
- laser emitting window
- battery cover
- compensator switch
- tripod mount 1/4″
Operation
Place the instrument on the working surface or mount it on the tripod/pillar
or wall mount.
Switch on the instrument: turn the compensator switch (3) to the position
“ON”.
When enabled, the vertical and horizontal planes are projected constantly.
Visual alarm (blinking line) and audible signal indicate that the device was
not installed within the compensation range ± 3 º. To properly work align the
unit in a horizontal plane.
APPLICATION DEMONSTRATION
For more information, you can visit our website www.adainstruments.com
To check the accuracy of the line laser level
To check the accuracy of the line laser level (slope of plane) Set up the
instrument between two walls, the distance is 5 m. Turn on the Cross Line
Laser and mark the point of the cross laser line on the wall.
Set up the instrument 0,5-0,7m away from the wall and make, as described
above, the same marks. If the difference {a1-b2} and {b1-b2} is less than the
value of “accuracy” (see specifications), there is no need for calibration.
Example: when you check the accuracy of Cross Line Laser the difference is
{a1-a2}=5 mm and {b1-b2}=7 mm. The instrument’s error: {b1-b2}-{a1-a2}=7-5=2
mm. Now you can compare this error with a standard error.
If the accuracy of the Cross Line Laser isn’t corresponding with claimed
accuracy, contact the authorized service center.
To check level
Choose a wall and set the laser 5m away from the wall. Turn on the laser and
cross the laser line is marked A on the wall.
Find another point M on the horizontal line, the distance is around 2.5m.
Swivel the laser, and another cross point of the cross laser line is marked B.
Please note the distance of B to A should be 5m.
Measure the distance between M to cross the laser line, if the difference is
over 3mm, the laser is out of calibration, please contact the seller to
calibrate the laser.
To check plumb
Choose a wall and set the laser 5m away from the wall. Mark point A on the
wall, please note the distance from point A to the ground should be 3m. Hang a
plumb line from A point to the ground and find a plumb point B on the ground.
turn on the laser and make the vertical laser line meet point B, along the
vertical laser line on the wall, and measure the distance 3m from point B to
point C.
Point C must be on the vertical laser line, it means the height of the C point
is 3m.
Measure the distance from point A to point C, if the distance is over 2 mm,
please, contact the seller to calibrate the laser.
Care and cleaning
Please handle the measuring instruments with care. Clean with a soft cloth
only after any use. If necessary damp cloth with some water. If the instrument
is wet clean and dry it carefully. Pack it up only if it is perfectly dry.
Transport in original container/case only.
Note: During transport On/Off compensator lock (3) must be set to position
“OFF”. Disregarding may lead to damage to the compensator.
Specific reasons for erroneous measuring results
- Measurements through glass or plastic windows;
- Dirty laser emitting window;
- After the instrument has been dropped or hit. Please check the accuracy.
- Large fluctuation of temperature: if the instrument will be used in cold areas after it has been stored in warm areas (or the other way round) please wait some minutes before carrying out measurements.
- Electromagnetic acceptability (EMC)
- It cannot be completely excluded that this instrument will disturb other instruments (e.g. navigation systems);
- will be disturbed by other instruments (e.g. intensive electromagnetic radiation nearby industrial facilities or radio transmitters).
Laser class 2 warning label on the laser instrument
Laser classification
The instrument is a laser class 2 laser product according to DIN IEC
60825-1:2007. It is allowed to use the unit without further safety
precautions.
Safety instructions
Please follow up instructions given in the operators’ manual. Do not stare
into the beam. The laser beam can lead to an eye injury (even from greater
distances). Do not aim laser beams at persons or animals.
The laser plane should be set up above eye level of persons. Use the
instrument for measuring jobs only.
Do not open the instrument housing. Repairs should be carried out by
authorized workshops only. Please contact your local dealer. Do not remove
warning labels or safety instructions.
Keep instruments away from children. Do not use instruments in explosive
environments.
Warranty
This product is warranted by the manufacturer to the original purchaser to be free from defects in material and workmanship under normal use for a period of two (2) years from the date of purchase. During the warranty period, and upon proof of purchase, the product will be repaired or replaced (with the same or similar model at the manufacturer’s option), without charge for either part of the labor.
In case of a defect please contact the dealer where you originally purchased
this product. The warranty will not apply to this product if it has been
misused, abused or altered. Without limiting the foregoing, leakage of the
battery, and bending or dropping the unit are presumed to be defects resulting
from misuse or abuse.
Exceptions from responsibility
The user of this product is expected to follow the instructions given in the
operators’ manual.
Although all instruments left our warehouse in perfect condition and
adjustment the user is expected to carry out periodic checks of the product’s
accuracy and general performance. The manufacturer, or its representatives,
assumes no responsibility for the results of faulty or intentional usage or
misuse including any direct, indirect, consequential damage, and loss of
profits. The manufacturer, or its representatives, assumes no responsibility
for consequential damage, and loss of profits by any disaster (earthquake,
storm, flood …), fire, accident, or an act of a third party and/or usage in
other than usual conditions.
The manufacturer, or its representatives, assumes no responsibility for any
damage, and loss of profits due to a change of data, loss of data and
interruption of business, etc., caused by using the product or an unusable
product. The manufacturer, or its representatives, assumes no responsibility
for any damage, and loss of profits caused by usage other than those explained
in the users’ manual.
The manufacturer, or its representatives, assumes no responsibility for damage
caused by wrong movement or action due to connecting with other products.
THE WARRANTY DOESN’T EXTEND TO THE FOLLOWING CASES:
- If the standard or serial product number will be changed, erased, removed or wil be unreadable.
- Periodic maintenance, repair or changing parts as a result of their normal runout.
- All adaptations and modifications with the purpose of improvement and expansion of the normal sphere of product application, mentioned in the service instruction, without the tentative written agreement of the expert provider.
- Service by anyone other than an authorized service center.
- Damage to products or parts caused by misuse, including, without limitation, misapplication or negligence of the terms of service instruction.
- Power supply units, chargers, accessories, and wearing parts.
- Products, damaged from mishandling, faulty adjustment, maintenance with low-quality and non-standard materials, presence of any liquids and foreign objects inside the product.
- Acts of God and/or actions of third persons.
- In case of unwarranted repair till the end of the warranty period because of damages during the operation of the product, it’s a transportation and storing, the warranty doesn’t resume.
WARRANTY CARD
Name and model of the product _____
Serial number __date of sale_
Name of commercial organization _____stamp of commercial
organization
The warranty period for the instrument exploitation is 24 months after the
date of original retail purchase.
During this warranty period, the owner of the product has the right to free
repair his instrument in case of manufacturing defects.
Warranty is valid only with original warranty card, fully and clear filled
(stamp or mark of the seller is obligatory).
Technical examination of instruments for fault identification which is under
the warranty is made only in the authorized service center.
In no event shall the manufacturer be liable before the client for direct or
consequential damages, loss of profit, or any other damage which occur as a
result of the instrument outage.
The product is received in the state of operability, without any visible
damages, and in full completeness. It is tested in my presence. I have no
complaints about the product quality. I am familiar with the conditions of
warranty service and I agree.
purchaser signature __
Certificate of acceptance and sale
__№_____
name and model of the instrument
Corresponds to ____
designation of standard and technical requirements
Date of issue __
Stamp of quality control department Price
Sold ____ Date of sale __name of commercial
establishment
ADA
MEASUREMENT FOUNDATION
WWW.ADAINSTRUMENTS.COM