Installation

Tools:

Optimal airflow: As far as possible inject the air into the driest room and extract from the most
humid room to eliminate the risk of leading the moisture through the rest of the building. The
thermostat and sensor should be protected from other heat sources or direct sunlight. They should be located in a place with good ventilation, but not directly in the air flow from the solar collector.

The hole: Please distinguish wooden house and brick wall, so the correct electric drill is adopted. If it is a brick wall, use a brick wall tool and a plastic expansion pipe. Take care not to drill into cables, power sockets, pipes, etc. If the wall or roof is not flat, pay attention to waterproofing. You can use polyurethane foam caulk, silicone or sealant to level it.

During installation, the outdoor air inlet must be facing downward and open. After installation, remove the film on the aluminum alloy. It will be ugly after sun exposure.

The thermostat is a mechanical thermostat or an LCD thermostat, and the indoor air outlet is automatic or manual. There are different configurations and installation methods, please refer to the actual product.

Placement: Installed facing south as much as possible. When placed 45 degrees from due south the system also works, but with an approx. 15% lower performance. Note that by setting up two panels, e.g. one facing east- southeast and one south-southwest, you can take full advantage of the available sunshine throughout the day.

Installation And Safety Instructions

Installation And Safety Instructions
Installation And Safety Instructions
Installation And Safety Instructions

LCD thermostat
mechanical thermostat

mechanical thermostat

Dimension

Product Overview

Model| OS10| OS20| OS30| OS40| OS22| OS32| OS32

for USA

| OS42
---|---|---|---|---|---|---|---|---
A| 517mm| 715mm| 916mm| 1004mm| 715mm| 916mm| 34.3in| 1968mm
B| 715mm| 1004mm| 1210mm| 1968mm| 1004mm| 1210mm| 46.1in| 1004mm
C| 258.5mm| 357.5mm| 458mm| 502mm| 130mm| 130mm| 5.1in| 130mm
D| 110mm| 130mm| 130mm| 130mm| 130mm| 130mm| 5.1in| 130mm
G|  |  |  |  | 743mm| 950mm| 35.8in| 743mm

Disassembly

Installation Instruction

Do not over-tighten the No. 9 black screw, the aluminum alloy will be deformed, and the sealing strip may fall out.

You can refer to the installation video on the website www.nakoair.net

View the installation video: scan the QR code
QR Code Icon

The following part is just for

The temperature and humidity meter cannot be directly exposed to the sun.
part
part

Avoid placing the photoelectric switch of the air outlet directly at sunlight or incandescent lamps light. Please install the photoelectric switch facing down to avoid possible sunlight.
part
part

The following part is just for mechanical thermostat

mechanical thermostat

There is no distinction for negative or positive poles. The panels are thermostatically controlled so that the fan turns off when a certain temperature is reached. It needs to be set above 15℃ for the fan to work. Thermostat installed in the room. If you want to prevent cold air from entering the room, please connect ① and ④, and then put the thermostat inside the air intake duct. When the temperature is lower than the temperature set by the thermostat, such as 12 ℃, the fan will not work.

Applications

  • in holiday cabins
  • in residential and commercial buildings
  • in the cottages and summer residences
  • in caravans and tents
  • in conservatories
  • in cellars and storage areas
  • in football and other sports cabins
  • in areas without electrification

Operation

Thermostat set value is higher than the room temperature.
Function 1 Standard: Heating outdoor fresh air. Available for all models.
Operation

Function 2 Indoor air circularly heating mold:
The distinct internal circulation can keep heating the room air. When the outdoor temperature is too low, just open the air inlet indoor to keep heating the indoor air. Just close the air inlet indoor to introduce and heat the fresh air outdoor. Available for OS22/32/42.

If you want to increase the heating efficiency and dehumidification effect, please increase the wind speed, the heat loss will be reduced. Please turn down the air outlet, if you need air going to the room with higher temperature;
Or feel too noisy. If you want to test the air temperature, please use a thermometer. Somatosensory temperature is greatly affected by wind speed, and cannot accurately detect wind temperature and heating effect.
Operation

Function 2 Indoor air circularly heating mold:

The distinct internal circulation can keep heating the room air. When the outdoor temperature is too low, just open the air inlet indoor to keep heating the indoor air. Just close the air inlet indoor to introduce and heat the fresh air outdoor. Available for OS22/32/42.

If you want to increase the heating efficiency and dehumidification effect, please increase the wind speed, the heat loss will be reduced. Please turn down the air outlet, if you need air going to the room with higher temperature; Or feel too noisy. If you want to test the air temperature, please use a thermometer. Somatosensory temperature is greatly affected by wind speed, and cannot accurately detect wind temperature and heating effect.

Part of the reason for not working:

The solar air heater don’t raise the temperature or ventilate in these situations:
The power displays abnormal, LCD screen does not turn bright, all the value displays 0, sometimes it shows only 4V, flickers, the voltage is insufficient.

Solution:

  1. The day is sunny, however the angle of sunlight is wrong. Maybe the sun is directly above or tilted too much.
  2. Check if the pv panel is shaded by the trees or buildings etc. Make the whole pv panel is exposed in the sunlight. Any shadows on the pv panel might impact the generation of power. If it’s overcast, the sun isn’t shining or is only shining weakly, during the night, early in the morning or late at night and when the panel is covered by snow or ice or during rain.
  3. Pull the wires out and try to plug it back in the thermostat. Maybe it’s a hit.
  4. Just for LCD thermostat. The correct clock must be set for the collector to work normally. The temperature and humidity display, or the operation of the fan and automatic air vent will have some lag. Within 10-30 minutes, the work will start when stable light is detected. It is recommended to check again after half an hour.
    If the problem is still not resolved, please open the silver tape. It is possible that a connection cable has been disconnected; It could be a wire collision. Please use an electric tape to connect it back. If you need to replace the fan, please open the fan cover. The rear panel is attached with screws that can be removed. After repairing, just screw the two symmetrical screws back.
    Please take photos for us to find the solution. As long as the photovoltaic panel is good, it can be repaired. If you can do a few tests that will help us determine what is wrong with that solar air heater it would be very helpful.

Repair—You can substitute the spare parts except pv panels all by yourself with easy tools like scissors, tape, screwdriver.

Maintenance

6 years Warranty for Oscar solar air heater: Aluminum alloy frame, glass and photovoltaic panels are guaranteed for 6 years. Sun on fan warrant 40000 hours. Thermostat, air outlet can be replaced free of charge within 2 years.

Environmental requirements

Waste cartons, foam and plastic bags, please put in the designated bins.

Product information for solar air heater:

Felt cover heater

Model OS10 OS10H OS20 OS22 OS30 OS32 OS40 OS42
Appro room area 10m2 15 m2 30-40m2 50-60m2 100m2
Maximum         air volume 42m3 / h 88 m3/h 88 m3/h 98m3/h 105 m3/h
113m3/h 128m3

/ h

| 135m3/

h

Approx

temperature rise

| 50 C| 30 C| 100 C| 110 C| 150 C| 160 C| 240 C| 250 C
Max performance

(w/h)

| 265W| 300W| 520W| 550W| 800W| 840W| 1310 W| 1380W
Product size(cm)| 71x52x6| 52x71x6| 101x72x6| 121x92x6

(USA:34 x 46 x 2.4inch)

| 197x100x6
Carton size(cm)| 92x57x9| 92x57x9| 120x76x9| 126x95x9| 204x106x9
Net weight| 8kg| 8kg| 15kg| 18kg| 33kg
Gross Weight| 10kg| 10kg| 18kg| 19kg| 22kg| 23kg| 38kg| 39kg

Felt cover heater:

The special felt cover can be spliced with aluminum alloy collector (OS10H/20/22/30/32) and installed on a flat roof or wall. The air through the black felt gap (air intake volume remains unchanged) can efficiently absorb the heat of the sun, thereby increasing the temperature of the outdoor fresh air entering the room. As long as the felt cover is spliced, the temperature of the fresh air entering the room can be increased: F7—-about 10℃; F11—- about 15℃; F11H —-about 15℃.

After a long period of outdoor dust and rain test, the air intake volume is reduced by up to 3%.
It can effectively filter Dust and become clean after rain washing, no maintenance is required. The service life is more than 5 years.

Felt cover (Can’t be used alone)| F7 For OS10H/20/22| F11/ for OS30/32| F11H( horizontal ) for OS32
---|---|---|---
Appro temperature rise| 100 C| 150 C| 150 C
Max performance(w/h)| 520W| 800W| 800W
Estimated energy supplement kwh/unit/year| 525kwh| 770kwh| 770kwh
Product area| 0.7 ㎡| 1 ㎡| 1 ㎡
Product size(cm)| 101x72x6| 121x92x6| 92x121x6
Carton size(cm)| 101x10x10| 118x12x12| 118x12x12
Net weight| 1.5KG| 2.5KG| 2.5KG
Gross Weight| 2KG| 3KG| 3KG

Felt cover heater
Felt cover heater

Drill a hole with a self-drilling screw, and then withdraw the screw.

Felt cover heater

You can refer to the installation video on the website:
Felt cover heater
Scan QR code
QR Code Icon

Maintain records

  Maintenance project Problem Solutions Date
1      
2      
3      
4      
5      

Dear customer,

Thank you very much for purchasing our solar air collector! Are you satisfied with our products, services, logistics and after-sales?

If you are satisfied, your comment is really important to us.

Our products also ventilate, dehumidify and purify the air. In spring and autumn, the sun will be much better and the effect will be much better. In addition, the temperature on the sunny side usually rises by more than 10°C under the bright sun. Solar products are environmentally friendly and very useful for reducing greenhouse gas emissions. Reducing the air volume can increase the temperature and reduce the noise; increasing the air volume can improve the heating efficiency and dehumidification effect. If you want to test the air temperature, use a thermometer. The body temperature is greatly affected by the wind speed, and the air temperature and heating effect cannot be accurately detected. If you are
not satisfied, please contact us, we will improve.

Thank you very much for your support of our work!

We wish you a happy life!
icons

icons
Provides a healthy indoor climate at your home.

Avoid humidity Avoid stale smell Avoid mould and fungus

CE Contact in the EU: Allan Dong 0034690129524 (CE contact only)
Oscar Science & Technology Co., Ltd.
Website: www.nakoair.net