OSCAR OS20 LCD Thermostat Instruction Manual
- June 14, 2024
- Oscar
Table of Contents
OSCAR OS20 LCD Thermostat Instruction Manual
**Power Adapter
**
Output: 5V 1A forOS20/22/30/32; 5V 2A for OS40/42 **
**
Screen display
Connecting to power|
Ventilating| In indoor circulation
---|---|---
Automatic(default)| Humidity control| ****Manual
Heating and ventilation| Continuous heating of indoor air
Function description
Switch| Press 2s to enter the setting| Mode selection
---|---|---
Function description **
**
Heating in the sun in the spring/ fall/ winter
LCD Thermostat| When presetting temperature is higher than indoor
temperature.
Automatic mode| Sunshine-12am| 12:00 am— 3:00 pm| 3pm–no Sunshine
Only for OS22/32/42| Keep heating indoor air circularly| Heating outdoor fresh
air (Spring and autumn can increase ventilation time)| Keep heating indoor air
circularly
For OS20/30/40| Just heating outdoor fresh air in the sun
In the process of heating indoor air, if the following conditions occur,
the device will automatically turn to heat the outdoor fresh air.
1. Outdoor air (moisture content) is dryer than indoor| and indoor relative
humidity ≥75%
2. Outdoor air is wetter than indoor air| and Indoor relative humidity ≤30%
3. When it is detected that the outdoor temperature is higher than the indoor
temperature.
Humidity control mode| Sunshine-11am| 11am— no sunshine
Only for OS22/32/42| Keep heating indoor air circularly| Heating outdoor fresh
air (Spring and autumn can increase ventilation time)
For OS20/30/40| Just heating outdoor fresh air in the sun
In the process of heating indoor air, if the following conditions occur,
the device will automatically turn to heat the outdoor fresh air.
1. Outdoor air (moisture content) is dryer than indoor| and Indoor relative
humidity ≥70%(60%-75%)
2. Outdoor air is wetter than indoor| and Indoor relative humidity
≤40%(30%-45%);
3. When it is detected that the outdoor temperature is higher than the indoor
temperature.
In the process of ventilation, if the following conditions occur, the fan
stops working.
Outdoor air (moisture content) is wetter than indoor air| and indoor relative
humidity ≥70%
Manual mode| Can set a time period to heat fresh air or air indoor
Heating fresh air mode| Just heating outdoor fresh air
Heating indoor air mode| Keep heating indoor air circularly
Electricity mode
LCD Thermostat| All models can only introduce fresh outdoor air to
regulate indoor temperature and humidity.
Automatic mode| In the Spring/Fall/Winter| In the Summer
Automatic ventilation| When outdoor temperature is higher than indoor.| When
outdoor temperature is lower than indoor.
---|---|---
Ventilation 1-3h from 13pm, keep the room fresh.| Outdoor 2-15℃ (adjustable)|
Outdoor 15-23℃ (adjustable)| Outdoor 23-28℃ (adjustable)
Ventilate for 1h| 2 hours| 3 hours
Outdoor air (moisture content) is dryer than indoor| and indoor relative
humidity ≥85%
Outdoor air (moisture content) is wetter than indoor| and indoor relative
humidity ≤35%
Will ventilate to regulate moisture content indoor
In the process of ventilation, if the following conditions occur, the fan
stops working.
Outdoor air (moisture content) is dryer than indoor| and indoor relative
humidity ≤35%
Outdoor air (moisture content) is wetter than indoor| and indoor relative
humidity ≥85%
Humidity control mode : Indoor relative humidity adjustment range: 30%
-45%; 60% -75%.
Outdoor air (moisture content) is dryer than indoor| and indoor relative
humidity ≥70%
Outdoor air (moisture content) is wetter than indoor| and indoor relative
humidity ≤40%
Will ventilate to regulate moisture content indoor
Manual mode| Can set 2 time periods freely to ventilation.
Heating fresh air mode| In the Spring/Fall/Winter| In the Summer
Automatic ventilation| When outdoor temperature is higher than indoor.| When
outdoor temperature is lower than indoor.
Ventilation 1-3h from 13pm, keep the room fresh.| Outdoor 2-15℃ (adjustable)|
Outdoor 15-23℃ (adjustable)| Outdoor 23-28℃ (adjustable)
Ventilate for 1h| 2 hours| 3 hours
Operation
-
During the operation, some icons or parameters will flash, indicating that they are being
adjusted. If they are not operated within 10 seconds, the display will be on for a long time, indicating that they are in the state of the icon or parameter. If there is no operation for 10 minutes, the screen will turn off. -
The temperature and humidity display, or the operation of the fan and automatic air vent will
have some lag. The program will run automatically. -
Pressing the SET button a third time displays the preset room temperature in this mode, which defaults to 26 ° C.
-
After selecting one of the 5 modes, the corresponding mode will run after 10s.
-
Solar energy is the priority, and electricity is used without solar energy. Please plug in the power when there is electricity, or the automatic vents may not close when the clouds suddenly block the sun. The power supply can reduce the operation times of the automatic air outlet and reduce the noise.
-
To Fahrenheit users: Press the key at the same time to switch between Celsius
and Fahrenheit display. When setting the temperature, the unit is still Celsius; after setting, the temperature displayed on the screen will automatically switch.
5°C=41°F;10°C=50°F;15°C=59°F;20°C=68°F; 23°C=73.4°F;26°C=78.8°F; 28°C=82.4°F
Time setting
The correct clock must be set for the collector to work normally. To set
the clock, press the SET and
M buttons at the same time for more than 2 seconds.
Mode selection
**Wind speed adjustment in current mode:
Automatic mode in solar**
Ventilation start time, the default is 4 am;
Switch to heating outdoor fresh air, default 12 o’clock at noon;
Switch to continuous heating of indoor air, default 15 o’clock.
Automatic mode in power use
13:00 – 14:00: The outdoor temperature is in the TIME1-TIME2 range (default
2-15 ° C), and the fresh air runs for 1 hour;
13:00 – 15:00 :
The outdoor temperature is in the TIME2-TIME3 range (default 15-23 ° C), and
the fresh air runs for 2h; 13:00 – 16:00:
The outdoor temperature is in the TIME3-TIME4 range (default 23 ° C -28 °
C), and the fresh air runs for 3h. By adjusting the temperature values
represented by TIME1, 2, 3, and 4, the start-stop temperature and ventilation
time of the fresh air can be adjusted. For example, lowering TIME2 and TIME3
can extend the ventilation time; conversely, increasing TIME2 and TIME3 can
reduce the ventilation time.
Humidity control mode in solar
Ventilation start time, the default is 4 am;
Switch to heating outdoor fresh air, default 11 o’clock at noon;
Switch to continuous heating of indoor air, default 21 o’clock;
Upper limit of indoor relative humidity: The default is 70%, and the
range is 60% -75%
Lower limit of indoor relative humidity: The default is 40%, and the
range is 30% -45%.
Humidity control mode in power use.
Upper limit of indoor relative humidity: The default is 70%, and the range is
60% -75%
Lower limit of indoor relative humidity: is 30% -45%The default is 40%,
and the range
Manual mode in solar
Ventilation start time, the default is 4 am;
Ventilation stop time, the default is 20 pm.
Manual mode in power use
Ventilation start time, the default is 13 o’clock;
Ventilation stop time, the default is 15 o’clock.
Ventilation start time, the default is 17 o’clock.
Ventilation stop time, the default is 17 o’clock.
Heating and ventilation mode in solar
Ventilation start time, the default is 4 am;
Ventilation stop time, the default is 20 pm.
Heating and ventilation mode in power use
3:00 – 14:00: The outdoor temperature is in the TIME1-TIME2 range (default
2-15 ° C), and the fresh air runs for 1 hour;
13:00 – 15:00: The outdoor temperature is in the TIME2-TIME3 range (default
15-23 ° C), and the fresh air runs for 2h;
13:00 – 16:00: The outdoor temperature is in the TIME3-TIME4 range (default
23 ° C -28 °C), and the fresh air runs for 3h.
By adjusting the temperature values represented by TIME1, 2, 3, and 4, the
start-stop temperature and ventilation time of the fresh air can be adjusted.
For example, lowering TIME2 and TIME3 can extend the ventilation time;
conversely, increasing TIME2 and TIME3 can reduce the ventilation time
Continuous heating of indoor air mode in solar
Ventilation start time, the
default is 4 am;
Ventilation stop time, the default is 20 pm.
Part of the reason for not working:
The operation of the fan or air vent will have lag. Within 10-40 minutes, the
work will start when
stable Sunshine is detected(cannot be interrupted). Insufficient sunlight,
wrong lighting angle, and
cloudy may interrupt the program. The fan can work only when the virtual load
voltage(Not working voltage) is higher than 16V, 40min; or 18V, 20min. The
correct clock must be set for the collector to work normally. To set the
clock, press the SET and M buttons at the same time for more than 2 seconds.
The human body can interfere with the analog signal. When testing the auto air
vent or LCD thermostat, please do not hold them with your hands and connect
the wire to auto air vent. Otherwise, it may not work. If there is a problem
with the display and the function is not normal, it is likely that the wire is
not plugged in tightly. Please unplug it and plug it in again. Avoid placing
the photoelectric switch of the air vent directly at sunlight or incandescent
lamps light
If the room temperature is higher than 24℃ (such as in summer), it may not
work. Please set the
temperature higher, such as 32℃, the device will start to work normally. Some
power adapters may have unstable voltage, interruption or black screen in DC
mode, etc. Please replace the power adapter. If you feel that the automatic
air vent is noisy, please plug in the power to reduce the operations. Reduce
the use of automatic mode. To obtain reasonable moisture, cold air may enter
the room in the dry mode. The three–core wire connector must be inserted,
otherwise the PV panel will display 0V. Use iron wire in series with red and
yellow wires of three-core wire to test if the fan works. The warranty period
is 2 years from the date of purchase . After disposal, please dispose of
this product in an environmentally friendly manner:
Scan QR code, View the web version of the manual,
Documents / Resources
|
OSCAR OS20 LCD
Thermostat
[pdf] Instruction Manual
OS20, OS22, OS30, OS32, OS40, OS42, OS20 LCD Thermostat, LCD Thermostat,
Thermostat
---|---
References
- Air collector Solar heater ventilator panel heat pump Fan Conditioning – Oscar Science & Technology Co., Ltd.
- Air collector Solar heater ventilator panel heat pump Fan Conditioning – Oscar Science & Technology Co., Ltd.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>