SALUS RT10 Indoor Electronic Room Thermostat Instruction Manual
SALUS RT10
Electronic room thermostat for radiant panel, radiator and convector heating systems
Installation and operating instructions
General
**** Congratulations on choosing to purchase a SALUS room thermostat. In
selecting the RT10 model you have opted for an electronic room temperature
controller that can boast some considerable advantages over its conventional,
mechanical counterparts. This controller is very simple to use with its stan-
dard rotary knob and, with its state-of-the- art electronics, it can offer you
unparalleled ease of control for all manner of heating systems.
The RT10’s features, which are described in detail below, ensure that you can
control your heating system in a precise, easy and energy-saving way.
Technical characteristics
Pulse width modulation (PWM).
Radiant panel heating systems tend to have a problem with overshooting, i.e.
rooms continue to be heated even after the desired temperature has been
reached and the valve has been closed. The RT10 solves this problem
electronically and especially effectively using what is known as pulse width
modulation. By continuously comparing set temperature with
actual temperature, the lengths of opening times for the valve actuators are
regulated in such a way that the temperature is almost completely prevented
from exceeding or falling below the set temperature. In this way, the required
temperature setting is regulated in a precise and convenient way. Note:
When the RT10 is used with radiator or convector heating systems, pulse width
modulation can be switched off if necessary (see ‘Basic settings’ section).
Valve protection function
To ensure that valves remain movable and ready for use even when they are
unused for considerable periods – e.g. over the summer – the RT10 includes a
valve protection func- tion. Briefly once a week, even when there is no
requirement for any heat, the valve actuators open the valves that they
control. Note: The valve protection function can be switched off if it is not
required (see ‘Basic settings’ section).
Temperature reduction.
Timed and demand-oriented heating con- trol are amongst the best ways of
managing heating energy in an economical way. The RT10 has an integrated
temperature reduction function which enables you to automatically reduce the
set temperature by 4K with no need for any costly add-on instal- lation on the
boiler controller. This ‘night reduction’ can be activated by an external
signal, e.g. time control from a terminal strip, or using a standard external
timer.
Installation
The RT10 room thermostat is designed as an electronic temperature controller for the electrical fine adjustment of hot-water based heating systems, and is used for controlling electro-thermal valve actuators or other electrical devices. It is vitally important that the maximum switching current specified in the technical specifications should not be exceeded! We are not liable for any form of improper use.
This equipment must only be installed by an authorised, qualified engineer, and only in accordance with the wiring diagram. Installation must also be in accordance with the latest VDE regulations as well as your electricity supplier’s regulations. The system must be in a de-energised state whilst installation is carried out, and all safety instructions must be followed to the letter.
Find a position for the thermostat where it is not covered by curtains,
furniture or anything else. The controller must not be installed too close to
any heat source (lights, stove, direct sunlight etc.), nor should it be
installed in a position where it will be exposed to draughts. The controller
must be installed in a suitable location in order for room temperature to be
monitored accurately and accordingly regulated with precision.
Important: The thermostat must be disconnected from its power supply
before its housing is opened.
Wall mounting The housing cover must be separated from the base plate before
the controller is fitted. Follow the steps listed below:
- Carefully pull off the adjuster wheel.
- Remove the screw from under the adjuster wheel.
- Open the housing by pulling off its cover on the adjuster wheel (right) side.
Now, using the screws supplied, screw the base plate firmly to the wall or the flushmounted socket. Wiring diagram
The thermostat must be wired in accordance with the wiring diagram below
RT 10 230 Volt Model
Terminal|
| Lead for temperature reduction (230V timer)
N| Neutral conductor supply lead
L| 230V power supply lead
| Switch output (valve actuator, terminal strip)
RT 10 24 Volt Model
Terminal|
| Lead for temperature reduction (24V timer)
L2| 24V power supply lead
NC| Circuit closed once temperature reached1
| Centre-point connection
NO| Circuit open once temperature reached2
L1| 24V power supply
RT 10| Technical data| 230 V| 24 V
---|---|---|---
Product no.:| 412.100| 412.101
Operating voltage:| 230V AC / 50Hz| 24V AC / 50 Hz
Electronic switch output
Max. switching current.:
|
10 (3) A
Max. no. of valve actuators.:| 5 Stück à 3W
Temperature range:| 5°- 30°C
Protection class:| IP 30
Dimensions W/H/D:| 75mm / 75mm / 30,5mm
Operating temperature:| 0°- 50°C
Storage temperature:| -25° – 65°C
Control pollution:| Normal
Basic settings
The jumpers on the PCB can be used to turn on or off various functions of the RT10.
OperationThe factory setting for all these functions is ON. You can change
these settings according to your own requirements by moving the contact
terminals on the jumpers. Important: The contact terminals should not be
removed.
As long as the installation is carried out to a professional standard, the
criteria for protection class II will be satisfied.
** The RT10 electronic room thermostat is used for regulating the
temperature in dry, enclosed rooms with a normal environment and maximum
humidity of 95% (non- condensing).
It is extremely simple and convenient to set the desired room temperature
using the rotary knob. This electronic control system ensures that the set
room temperature is maintained virtually without fluctuation and, when
required, automatically activates a reduction in temperature.
_ Never use anything other than a soft, dry cloth to clean the unit. Never
use any cleaning agents containing solvents or any sharp objects to clean the
unit.**_
IMPORTER:
QL CONTROLS Sp. z o.o. Sp. k. ul. Rolna 4, 43-262 Kobielice
PRODUCER: Salus Limited
6/F, Building 20E, Phase 3, Hong Kong Science
Park, 20 Science Park East Avenue, Shatin,
New Territories, Hong Kong
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>