Safety notes

Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non- observance of the manual are excluded from our liability and not covered by our warranty.

  •  The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
  •  The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
  •  Do not expose the device to shocks or strong vibrations.
  •  The case should only be opened by qualified PCE Instruments personnel.
  •  Never use the instrument when your hands are wet.
  •  You must not make any technical changes to the device.
  • The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents.
  •  The device must only be used with accessories from PCE Instruments or equivalent.
  •  Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
  •  Do not use the instrument in explosive atmospheres.
  •  The measurement range as stated in the specifications must not be exceeded under any circumstances.
  • Non-observance of the safety notes can cause damage to the device and injuries to the user.
  •  Do not cover the back of the meter as this may cause malfunction.

We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of business. If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual.

Device description

Front and back

  1. On/off key
  2.  Right key
  3. Left key
  4.  Micro USB charging socket

Display

Technical specifications

Measurement range CO 2 Accuracy

Resolution

| 400 … 5000 ppm CO2

±75 ppm or ±5 % of rdg. (the higher value applies) 1 ppm

---|---
CO2 sensor| NDIR
Measurement range humidity Accuracy

Resolution

| 20 … 95 % RH

±4 % RH

1 % RH

Display| 4.3″ LC display
Sampling rate| 1.5 s
Environmental conditions| -10 … 50 °C / 20 … 85 % RH
Power supply| 3.7 V Li-Ion battery 3000 mAh 5 V micro USB
Battery life| 6 h
Charging time| 2 h
Dimensions| 145 x 78 x 97.2 mm
Weight| 210 g

Delivery scope

  • 1 x CO2 analyser PCE-CMM 5
  • 1 x USB charging cable 5 V / 2 A
  • 1 x user manual

Operating instructions

Switch on the device
When the CO2 monitor is off, press and hold the on/off key for 3 seconds to turn on the meter.

Switch off the device
When the power is on, press the on/off key for 3 seconds to switch off the meter.

Toggle view
When the unit is switched on, all measured values are displayed as numerical values. Furthermore, the CO2 meter shows the air quality status in a green-yellow-red status lamp. Use the arrow keys (left / right) to switch to the graph. The graph shows the course of the CO2 content of the last 5 h after switching on.

CO2 traffic light function
The CO2 monitor has a status lamp display (CO2 traffic light). The limit values for color changes are as follows:

Air quality CO2 content Colour
Good 400 … 800 ppm Green
OK 800 … 1200 ppm Yellow
Poor 1200 … 5000 ppm Red

Settings

Press the on/off key twice in quick succession to open the settings menu.

Setting the date (DATE)
Use the left and right keys to change the highlighted value for day, month, year. Confirm the setting with the on/off-key.

Setting the time (TIME)
Use the left and right keys to change the highlighted numeric value for hour and minute. Confirm the setting with the on/off-key.

Select unit (UNIT)
You can switch between °C and °F using the left and right keys. Confirm the setting with the on/off-key.

Set temperature offset (TEMP)
To set an offset for the measured temperature value, use the left and right keys to change the numerical value. Confirm the setting with the on/off-key.

Automatic calibration
The PCE-CMM 5 has the integrated self-correcting ABC algorithm (Automatic Baseline Correction) for automatic adjustment of the baseline value. This calibration is performed once a day.
For this, the PCE-CMM 5 requires a regular supply of fresh air. The measured value is adjusted automatically. The ABC function is permanently switched on (cannot be switched off) and adjusts the baseline value at regular intervals when the CO2 level is low. Do not use this meter in a closed environment where the CO2 concentration remains relatively high. This would adversely affect the self-correction of the meter.

Charge the meter
When the battery icon on the display indicates that the battery is discharged, the PCE-CMM 5 must be charged via the micro USB port. To do this, use the supplied USB charging cable or a USB power supply with 5 V / 1000 mA. Please note that it may take at least 2 hours to recharge the battery to 100 %.

Note:
Charging via a 500 mA port on the computer is not possible.

Warranty

You can read our warranty terms in our General Business Terms which you can find here: https://www.pce-instruments.com/english/terms.

Disposal

For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company that disposes of the devices in line with the law. For countries outside the EU, batteries, and devices should be disposed of in accordance with your local waste regulations. If you have any questions, please contact PCE Instruments.

PCE Instruments contact information

United Kingdom PCE Instruments UK LtdUnit 11 Southpoint Business Park Ensign Way, Southampton Hampshire

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

PCE Instruments User Manuals

Related Manuals