Features:
- Clear functional design
- Easy reading of the outside temperature from the inside
- Maximum and minimum values with auto reset
- Easy to fix, demountable for window cleaning
- Weather-resistant
Digital Window Thermometer
Instruction manuals
www.tfa-dostmann.de/en/service/downloads/instruction-manuals
Use:
Open the battery compartment by a screwdriver and remove the battery insulation strip. Close the battery compartment carefully. Remove the protective films from both sides of the display. The device is now ready for operation. For transparent packaging, the UV and rain protection (see below) is already pre-assembled. To remove both protective films, first, remove the plastic plate. The upper display shows the maximum temperature, the middle display the current temperature and the lower display the minimum temperature.
Important note for the use: Due to the heat emission (depending on insulation) and the protected location of your window it is possible that the temperature displayed on your VISION is higher than the outdoor temperature at a free unsheltered location directly over the ground.
MAX/MIN temperatures:
- There is an automatic reset of maximum temperature at 8:00 and minimum temperature at 20:00. Therefore the current time must be set.
Setting of clock:
- Press the MODE button to enter setting mode. Set the hours by pressing the “+” button. Hold and press the button for a fast count.
- Press the MODE button again to set minutes in the same way.
- To go back to normal mode press the MODE button once more.
Installation:
Fix the holder with the enclosed adhesive outside at the window. Please clean the window glass before. Now you can hang up and demount the thermometer very easily.
Attention:
Avoid direct sunshine: It falsifies the indicated values! Extremely high
temperatures may lead to damage of the display. Permanent sunshine may bleach
the liquid crystals. To improve UV and rain protection and the clearness of
the display especially when it’s dark you find enclosed a plastic plate (pre-
assembled in transparent packaging). We recommend the use particularly when
your VISION window thermometer is located at the weather side or exposed to
strong solar radiation. Simply put the plate in the provided slots behind the
display. Attention! The display is delicate! Do not pull or bend when removing
the plate or demounting the thermometer.
Battery replacement:
- Replace the battery when the display becomes weak.
- Remove the instrument from the holder. Open the battery compartment by a screwdriver and remove the battery. Insert a new battery (1.5 V AAA).
- Close the battery compartment carefully.
- Use alkaline batteries only. Observe correct polarity.
For your safety:
- The product should only be used as described within this instruction.
- Unauthorized repairs, modifications or changes to the product are prohibited.
Caution! Risk of injury:
- Keep this instrument and the battery out of reach of children.
- Batteries contain harmful acids and may be hazardous if swallowed. If a battery is swallowed, this can lead to serious internal burns and death within two hours. If you suspect a battery could have been swallowed or otherwise caught in the body, seek medical help immediately.
- Batteries must not be thrown into a fire, short-circuited, taken apart or recharged. Risk of explosion!
- Low batteries should be changed as soon as possible to prevent damage caused by leaking.
- Wear chemical-resistant protective gloves and safety glasses when handling leaking batteries.
Care and maintenance:
- Do not place the unit near extreme temperatures, vibrations or shocks.
- Clean it with a soft damp cloth. Do not use solvents or scouring agents.
- Remove the battery if you do not use the product for a long period of time.
Waste disposal:
Never dispose of empty batteries and rechargeable batteries in household
waste. As a consumer, you are legally required to take them to your retail
store or to appropriate collection sites depending on national or local
regulations in order to protect the environment.
The symbols for the heavy metals contained are:
Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labeled in accordance with the EU Waste Electrical and Electronic Equipment Directive (WEEE). Please do not dispose of this instrument in household waste. The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment, in order to ensure environmentally-compatible disposal.
Specification:
- Measuring range: -25°C to +70°C
- Precision: 0°C to 50°C ± 1°C, otherwise ±1.5°C
- Resolution: 0.1°C
- Battery: 1.5 Volt AAA
TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, D-97877 Wertheim, Germany No part of this manual may be reproduced without the written consent of TFA Dostmann. The technical data are correct at the time of going to print and may change without prior notice. The latest technical data and information about this product can be found in our homepage by simply entering the product number in the search box..