kaiterra Sensedge Mini Air Quality Monitor
What’s Included
- Sensedge Mini
- Sensedge Mini sensor modules x 2
- Surface / Drywall mount
- Electrical box mount
- Drywall screws and anchors (3 pairs)
- Electrical box screws (US) x 2
- Electrical box screws (China and EU) x 2
- Fastening screws x 2
- USB cable
- Charger
- Certificate of calibration and testing
- User manual
- Certificate of conformity
Important Safeguards
Please read the safety warnings before use and take the necessary precautions to reduce the risk of fire, electric shock, or injury. The Kaiterra limited warranty applies only if the unit is used according to these instructions.
WARNING
- To reduce safety risks, always use service personnel from the manufacturer or service provider, or other qualified personnel for installation and maintenance.
- Make sure the power is OFF during installation or maintenance.
- DO NOT tamper with or use nonofficial spare parts for repair or maintenance.
- DO NOT use the device in environments with high humidity or possible direct exposure to water.
- DO NOT use the device in an outdoor environment.
- DO NOT use the device near heat sources such as radiators, furnaces, ovens, or stoves.
Getting Started
The Sensedge Mini is a commercial-grade air quality monitor. This user manual will provide a basic guide to its first use. Further information can be found on the Kaiterra Support Portal at http://support.kaiterra.com/sensedge-mini Operational Temperature:0 – 50℃
- Externals and Air Flow Air is drawn into the Sensedge Mini from the lower side, as well as the air intake on the upper side. It is vital that neither side of the device is covered. Any changes in airflow may affect the readings and accuracy.
- Power and Connectivity The Sensedge Mini provides multiple power and connectivity options:
- Power:
- USB-C: Only use the cable and charger/adapter supplied with the device
- DC direct wiring: Used for power supply of 12V, 1000mA
- PoE (Power over Ethernet): Available for model SE000200P
- Connectivity:
- 2.4GHz Wi-Fi (802.11 b/g/n)
- Ethernet: Used for data transfer via Ethernet
- RS-485: Used for Modbus communication
Sensor Modules
The Sensedge Mini utilizes a modular design to allow for easy control and
replacement of sensors. A CO2 sensor and a temperature and relative humidity
sensor areis built into the core of the device, and a variety of other sensors
may be inserted using the two sensor bays on the lower side of the device.
To insert a sensor module, simply align it with the bay and press it in,
ensuring the Kaiterra logo on the plastic tab is facing outwards. When
inserted correctly, the module will click into place, and an LED light above
the bay will briefly flash red if the device is powered on.
To remove a sensor module, gently pull the tab outward and remove the module
from the bay. Make sure to pull at a 90 degree angle.
Sensors may be inserted in either sensor bay, and in any order. They may be
swapped both when the Sensedge Mini is powered on and operational, and when
the device is turned off.
By default, the Sensedge Mini is shipped with the KM-200 and KM-203 sensor
modules, which together measure PM2.5, and TVOC., temperature, and relative
humidity.
Sensor Module Status Light Indications:
- Steady OFF Sensor working normal
- Flash red once Sensor module powered on
- Steady ON Sensor module needs to be changed
- Flash Sensor module failure
- Flash slowly Sensor module in sleep mode
Control and Status
Move the ON/OFF switch right to turn on the device. The STATUS light will go
on briefly to indicate the device has been powered on. To reset the device,
use a paperclip and hold down the RESET pinhole. The STATUS
light will flash red rapidly, indicating that the reset is successful.
STATUS Light Indications
Standard operation
- Steady OFF Device working normally
- Flash red once the Device is powered on
- Flash red rapidly Reset successful Configuration:
- Flash yellow Device in configuration mode Flash yellow rapidly for 5 seconds
- Identify via the configuration tool
- Flash green rapidly Connecting to the network
- Glow green gradually Connecting to the cloud
- Troubleshooting:
- Steady ON in red Device failure
- Flash red No network connection
Installation
The Sensedge Mini can be mounted on a concrete block wall, drywall, ceiling, or to an electrical box. For detailed instructions on installation, power, and connectivity setup, please visit our support center website at http://support.kaiterra.com/sensedge-mini or scan the QR code below.
Warranty Information
Katerra provides a 1-year limited manufacturer warranty on the Sensedge Mini. To obtain a copy of the warranty for this product, please visit https://support.kaiterra.com/policies
Troubleshooting
For additional support, please contact your sales representative or email us at support@kaiterra.com
References
- 📧support@kaiterra.com
- Sensedge Mini - Support Center
- Kaiterra - Air Quality Monitoring for Low Carbon Healthy Buildings
- Kaiterra Air Quality Monitoring Solutions - Made for Healthy, Smart Buildings
- Policies - Support Center
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>