SE-200PB Kaiterra Sensedge Mini Air Quality Monitor User Manual
- June 10, 2024
- kaiterra
Table of Contents
- What’s Included
- Important Safeguards
- Getting Started
- Externals and Air Flow
- Power and Connectivity
- Sensor Modules
- Sensor Module Status Light Indications
- Control and Status
- STATUS Light Indications
- Installation
- Warranty Information
- Troubleshooting
- FCC Caution
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SE-200PB Kaiterra Sensedge Mini Air Quality Monitor
What’s Included
- Sensedge Mini
- Sensedge Mini sensor modules x 2
- Surface / Drywall mount
- Electrical box mount
- Drywall screws and anchors (3 pairs)
- Electrical box screws (US) x 2
- Electrical box screws (China and EU) x 2
- Fastening screws x 2
- USB cable
- Charger
- Certificate of calibration and testing
- User manual
- Certificate of conformity
Important Safeguards
Please read the safety warnings before use and take the necessary precautions to reduce the risk of fire, electric shock, or injury. The Kaiterra limited warranty applies only if the unit is used according to these instruction
WARNING
-
To reduce safety risks, always use service personnel from the manufacturer or
service provider, or other qualified personnel for installation and maintenance. -
Make sure the power is OFF during installation or maintenance.
-
DO NOT tamper with or use nonofficial spare parts for repair or maintenance.
-
DO NOT use the device in environments with high humidity or possible direct exposure to water.
-
DO NOT use the device in an outdoor environment.
-
DO NOT use the device near heat sources such as radiators, furnaces, ovens, or
stoves
Getting Started
The Sensedge Mini is a commercial-grade air quality monitor. This user manual
will
provide a basic guide to its first use. Further information can be found on
the Kaiterra
Support Portal at http://support.kaiterra.com/sensedge-mini
Operational Temperature:0 – 40℃
Externals and Air Flow
Air is drawn into the Sensedge Mini from the lower side, as well as the air
intake on the
upper side. It is vital that neither side of the device is covered. Any
changes in airflow
may affect the readings and accuracy.
Power and Connectivity
The Sensedge Mini provides multiple power and connectivity options:
Power:
- USB-C: Only use the cable and charger/adapter supplied with the device
- DC direct wiring: Used for power supply of 12V, 1000mA
- PoE (Power over Ethernet): Available for model SE000200P
Connectivity:
- 2.4GHz Wi-Fi (802.11 b/g/n)
- Ethernet: Used for data transfer via Ethernet
- RS-485: Used for Modbus communication
- Bluetooth
Sensor Modules
The Sensedge Mini utilizes a modular design to allow for easy control and replacement of sensors. A CO2 sensor and a temperature and relative humidity sensor areis built into the core of the device, and a variety of other sensors may be inserted using the two sensor bays on the lower side of the device.
To insert a sensor module, simply align it with the bay and press it in, ensuring the Kaiterra logo on the plastic tab is facing outwards. When inserted correctly, the module will click into place, and an LED light above the bay will briefly flash red if the device is powered on.
To remove a sensor module, gently pull the tab outward and remove the module
from the bay. Make sure to pull at a 90 degree angle.
Sensors may be inserted in either sensor bay, and in any order. They may be
swapped
both when the Sens edge Mini is powered on and operational, and when the
device is
turned off.
By default, the Sens edge Mini is shipped with the KM-200 and KM-203 sensor modules, which together measure PM2.5, and TVOC., temperature, and relative humidity.
Sensor Module Status Light Indications
Steady OFF | Sensor working normal |
---|---|
Flash red once | Sensor module powered on |
Steady ON | Sensor module needs to be changed |
Flash | Sensor module failure |
Flash slowly | Sensor module in sleep mode |
Control and Status
STATUS Light Indications
Standard operation:
Steady OFF | Device working normal |
---|---|
Flash red once | Device powered on |
Flash red rapidly | Reset successful |
Configuration:
Flash yellow | Device in configuration mode |
---|
Flash yellow rapidly for
5 seconds
| Identify via configuration tool
Flash green rapidly| Connecting to the network
Glow green gradually| Connecting to the cloud
Troubleshooting:
Steady ON in red | Device failure |
---|---|
Flash red | No network connection |
Installation
The Sens edge Mini can be mounted on a concrete block wall, drywall, ceiling, or to an electrical box.
For detailed instructions on installation, power, and connectivity setup,
please visit our
support center website at http://support.kaiterra.com/sensedge-
mini or scan the QR
code below.
Warranty Information
Kaiterra provides a 1-year limited manufacturer warranty on the Sens edge Mini. To obtain a copy of the warranty for this product, please visit https://support.kaiterra.com/policies
Troubleshooting
For additional support, please contact your sales representative or email us at support@kaiterra.com
FCC Caution
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help. FCC RF
Radiation Exposure Statement:
- This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
- This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment.
- This equipment should be installed and operated with a minimum distance 20cm between the radiator & your body.
Adapter shall be installed near the equipment and shall be easily accessible.
The operating temperature of the EUT can’t exceed 40℃ and shouldn’t be lower
than 0℃.
The plug is considered as a disconnect device of adapter.
The product shall be connected to a USB interface of version USB2.0 or higher.
Hereby, Origins Technology Limited declares that this product is in compliance
with essential requirements and other relevant provisions of Directive
2014/53/EU. This product is allowed to be used in all EU member states
Made in China
www.kaiterra.com
support@kaiterra.com
Origins Technology Limited.
603 6/F, Laws Commercial Plaza, 788 Cheung Sha Wan Road, Hong Kong
References
- Sensedge Mini - Support Center
- Kaiterra - Air Quality Monitoring for Low Carbon Healthy Buildings
- Policies - Support Center
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>