TL-MBSEL200WH Anzzi Soft Close Manual Bidet Seat User Manual

June 13, 2024
ANZZI

TL-MBSEL200WH Anzzi Soft Close Manual Bidet Seat

Product Information

  • Product Name: ANZZI Soft Close Manual Bidet Seat
  • Model Numbers: TL-MBSEL200WH, TL-MBSRN201WH
  • Version: V1.1

Product Usage Instructions

Product Registration:

Register your product within 90 days to ensure coverage. You can register online at www.swcorp.com/register or mail in the completed registration card.

Installation:

Follow the instructions and guidelines in the owner’s manual and installation guide carefully for proper installation, operation, and maintenance of the product.

Product Dimensions:

  • TL-MBSEL200WH:
    • Dimensions: 19.7in x 6.9in x 2.3in
    • A = 16.9in x 18.7in
    • Other dimensions: 0.2in, 2.4in, 14.6in, 20.5in, 14.6in, 8.3in, 14.1in
  • TL-MBSRN201WH:
    • Dimensions: 18.9in x 6.9in x 2in
    • A = 16.1in x 17.9in
    • Other dimensions: 0.2in, 2.4in, 13.8in, 19.5in, 14.6in, 8.3in, 14.1in

Parts:

Refer to the general product drawing for a visual representation of the parts.

  • Cover plate
  • Template
  • Fix parts
  • Connecting bolt (2)
  • Expansion bolt (2)
  • Adjusting piece (2)
  • Nut (2)
  • Fixing plate (1)
  • Tee joint
  • Inlet hose
  • Installation Guide / User Manual
  • Filter screen

Note: There are two installation methods for this product – using the expansion bolt or the hiperfly nut. Please choose the appropriate method based on your preference and needs.

If you have any further questions or need assistance, you can contact us at 1-844-44-ANZZI or visit our website at www.ANZZI.com.

DON’T WAIT!
REGISTER NOW!
Register your product within 90 days to ensure your product is recognized as an official purchase and is eligible for warranty coverage.
Mail in the completed registry card (Pg. 2) or register online at www.swcorp.com/register.

PRODUCT REGISTRATION*

IMPORTANT: YOUR WARRANTY WILL NOT BE RECOGNIZED UNLESS THIS CARD IS FULLY COMPLETED AND RETURNED OR ONLINE REGISTRATION IS COMPLETED.

To ensure that your warranty is registered and confirmed please do one of the following:

  1. Register online at www.swcorp.com/register. You will be asked to fill out the same information you would in the registration card. Registering online is fast, secure and ensures we receive your information.
  2. Complete, cut-out and mail the registration card below. By returning this registration card we confirm the date of purchase for your new product. This confirmation will allow us to process any warranty claims.

Mail the card to: 5701 NW 35 Avenue, Miami, FL 33142

TL-MBSEL200WH Anzzi Soft Close Manual Bidet Seat-fig2

TL-MBSEL200WH

TL-MBSEL200WH Anzzi Soft Close Manual Bidet Seat-fig3

TL-MBSRN201WH

TL-MBSEL200WH Anzzi Soft Close Manual Bidet Seat-fig4

Part Name

General Product Drawing

Parts

Note: There are two installation methods for this product. The expansion bolt is the configuration of the recommended installation method, and the hiperfly nut is the configuration of another installation method. Please choose in practice.

Installation

Please read this manual carefully for correct installation.

Installation considerations

  1. Water pressure range: 0.07-0.8MPa(10~116PSI), please use according to the instructions.
  2. The angle valve shall be close to the installation and disassembly position of this product.

Installation steps

Installation preparation

  1. Insert the connecting bolt into the adjusting piece.
    Insert the connecting bolt into the hole of the adjusting piece in the direction shown in the figure.

  2. Insert the adjusting piece and connecting bolt into the fixing plate.
    As shown in the figure, insert the connecting bolts with the adjusting pieces into the holes of the fixing plate respectively.

Installation steps

Installation Method 1: (Recommended)

TL-MBSEL200WH Anzzi Soft Close Manual Bidet Seat-fig8

Installation Method 2

  1. Remove the old toilet lid and toilet seat and place the installation template on ceramic (see Article 1 and 3 of the first method).
  2. Align the fixing plate as shown in the figure (the fourth point of the first method is shown in the figure) with the ceramic hole, then adjust the positions of the connecting bolt and the adjusting piece, lock the hiperfly nut from the lower end of the ceramic to the upper end, and fix the fixing plate.
  3. For the rest of the installation steps, see Article 5 and 6 of the first method to complete the installation.
Connecting water pipes
  1. Close the angle valve and remove the water supply hose connected to the water tank. The tee joint is connected to the angle valve and ensures that the rubber sealing ring is installed therein.

  2. Connect the water supply hose to the tee joint.
    Note: The throttle cover and throttle 0-RING in the throttle valve shall be removed in the following two cases.
    a. When the inflow pressure is less than or equal to 0.05 MPa dynamic pressure. (e. G., domestic water tower, etc.)
    b. When the cover plate is installed and used, the nozzle cannot be sprayed normally.
    Disassembly steps:

  3. se pliers and other tools to clip the throttle valve out of the water inlet pipe.

  4. Remove throttle cover and throttle 0-RING. (Sealed 0-RING to be retained)

  5. Reinstall the throttle valve into the inlet pipe.
    Special reminder:
    When the inlet pressure is ≥0.1MPa, the throttle cover and throttle 0-RING must be retained in the throttle valve.

  6. After inserting the filters and rubber pads at both ends of the water inlet hose into the water inlet hose, connect the tee joint and the cover plate.

  7. Open the angle valve to check for water leakage.

Prohibit

  1. It is strictly prohibited to move products from the toilet lid, which is easy to cause mechanical failure.
  2. It is strictly prohibited to receive hot water above 40℃ and cold water that will freeze.

Operation Method

Hip cleaning function

  • Turn the knob from the vertical gear in the direction shown (clockwise).
  • Hip cleaning tut mouth stretch out, spray water cleaning.
  • The flow rate varies with the rotation of the knob.

TL-MBSEL200WH Anzzi Soft Close Manual Bidet Seat-fig13

Lower body cleaning function (for women)

  • Turn the knob from the vertical gear in the direction shown (counterclockwise).
  • The lower body cleaning nozzle extends out and sprays water for cleaning.
  • The flow rate varies with the rotation of the knob.

TL-MBSEL200WH Anzzi Soft Close Manual Bidet Seat-fig14

Stop cleaning and self-cleaning function (self-cleaning function is optional)

  • Turn the knob to the vertical (90°) position to turn off the cleaning function.
  • Before each use, the knob can be turned to the 25° gear and stayed for a few seconds to clean the nozzle. When the product is connected with warm water, it can also play a role in emptying cold water.
  • After each use, the nozzle can clean itself. If additional cleaning is needed for the nozzle, please turn the knob to the 25° gear and stay for a few seconds, then turn back to the vertical (90°) gear to turn off the self-cleaning function.

Cleaning and Disassembly

  1. Clean the external parts of the product.
    Use a smooth sponge or cloth with a neutral cleaner to clean the product. It is forbidden to use hydrogen chloride cleaner, diluent, benzene, sandpaper, polishing agent, perfume, pesticide and other cleaning products.

  2. Clean the nozzle.
    Gently pull out the nozzle and use a smooth cloth, sponge or toothbrush to remove the kitchen cleaner and wipe the nozzle.

  3. Clean filter screen and throttle valve
    (If you feel that the water flow is less than normal, please close the angle valve. )

  4. Separate the water inlet hose from the product and clean both ends of the filter screen of the water inlet hose with a brush.

  5. Please clean throttle valve 0 ~ RING. (Refer to Step 2 on Page 5 for removal and installation of throttle valve 0-RING)

  6. Remove the product cover plate.
    Close the upper cover of the product, press the disassembly button with your hand, and pull out the cover plate of the product in the direction of the arrow shown in the figure to disassemble.

TL-MBSEL200WH Anzzi Soft Close Manual Bidet Seat-fig19

Maintenance

  1. Knob replacement.

  2. Turn the knob to the maximum position in the hip washing direction as shown in Figure A.

  3. Pull out the old knob directly along the axis as shown in Figure B.

  4. As shown in Figure C, pull out the new knob along the old knob and insert the rib into the corresponding control valve slot. After hearing the “click” sound, the installation is completed.

  5. Nozzle replacement.
    After pulling out the conduit as shown in Figure A, grab the conduit and pull out the old nozzle directly along the axis.

  6. Throttle valve replacement.

  7. Turn the knob to the working position and clip the throttle valve out of the water inlet pipe with pliers and other tools.

  8. Press the new throttle assembly into the t hrottle valve at the bottom of the inlet pipe and replace it. Then turn the knob to the closed position.

  9. Water inlet pipe leakage maintenance.
    If there is water leakage at both ends of the inlet pipe, please tighten the nut again.

Problem Judgment and Product Specifications

Problem Judgment and Troubleshooting

Failure Reason Solution

Inadequate flushing water

| 1.Low water pressure| When washing, quickly turn the knob to the maximum gear of “washing” or “women washing”

2.Low water pressure

| If the water pressure is lower than the minimum water pressure of 0.07 MPa used by the product, please contact relevant departments to solve the water pressure problem of water supply.

Hip washing or woman washing can’t get out of water.

| 1.Angle valve closed| Open angle valve
2.Tee filter screen is blocked| Cleaning tee filter screen
3.The filter screen of the water inlet pipe is blocked.| Clean the filter screen of the water inlet pipe
4.Nozzle blockage| Remove nozzle for cleaning
5.External water pressure is too low| Increase external water pressure
When in use, the base leaks|

Excessive external water pressure

| The maximum water pressure used by the product is 0.8 MPa. If the water pressure exceeds 0.8 MPa, please contact relevant departments to solve the water pressure problem.

If the above corresponding treatment still cannot be used normally, or if there is any phenomenon other than this table, please contact the local designated maintenance center for maintenance.

Warning
Do not disassemble, repair or modify the product by yourself.

Product Specifications

Category Description
Model TL-MBSEL200WH, TL-MBSRN201WH
Hip cleaning flow rate 0.1 – 0.5 GPM
Women’s washing flow rate 0.1 – 0.5 GPM
Anti-backflow device One-way valve, vacuum switch
Water supply system Water-pipe supply
Water pressure requirement Static pressure: 0.07-0.8 MPa; Dynamic pressure:

above 0.03 MPa

Dimensions

| TL-MBSEL200WH| 14.6”X19.7”X2.4”
TL-MBSRN201WH| 14.6”X18.7”X2.4”

Weight

| TL-MBSEL200WH| 4.6LB
TL-MBSRN201WH| 4.4LB

Have questions? Call us at 1-844-44-ANZZI or visit us at www.ANZZI.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ANZZI User Manuals

Related Manuals