Introduction
This document mainly introduces the “QFlash” tool offered by Quectel and how
to use it to upgrade OpenCPU firmware.
This document is applicable to the following modules:
- MC25-OpenCPU
- M25-OpenCPU
- M56-R-OpenCPU
OS and Version
The flash tool can be run on a PC without installation if the OS is among the ones listed below:
- Windows 7
- Windows 10
Any newer version of the tool will be informed and provided by Quectel in advance.
NOTES
- In Windows 10, please start QFlash.exe by right-clicking the icon and selecting “Run as administrator”.
- The paths where the tool and firmware are stored should NOT contain any space, and English characters are preferred.
About QFlash Tool
The Q Flash tool developed by Quectel is shown as below (e.g. QFlash_V4.12 ).
OpenCPU Firmware Upgrade
Procedure
This chapter introduces how to upgrade OpenCPU firmware by using the QFlash tool (QFlash_V4.12 is taken for example). Generally, the following three steps can be applied:
- Step 1: Configure the parameters of serial port.
- Step 2: Load firmware files (core or App firmware).
- Step 3: Upgrade the firmware (core or App firmware).
The following sections describe the details about how to use the tool to upgrade firmware.
Configure Serial Port
After the QFlash tool is started, the main interface is shown as below.
Set COM Port
Click the “COM Port” dropdown list to select the serial port that corresponds
to the debug port of module, through which the firmware will be upgraded
.
Set Baud Rates
Click the “Baudrate” dropdown list and choose an appropriate baud rate.
For MC25&M25&M56-R-OpenCPU, please select “921600”, as shown in the following
figure.
NOTE: Baud rates have many different values. It is the hardware environment that determines whether the specified baud rate is supported or not; If not supported, an error message will be returned.
Load Firmware Files
Load App Firmware
Click the button “Load FW Files”, and select the “.lod” file of App firmware
that needs to be downloaded to the module.
Load Core Firmware
Click the button “Load FW Files”, and select the “.lod” file in core firmware
package (offered by Quectel) which needs to be downloaded to the module
.
Upgrade Firmware
Upgrade App Firmware
Step 1: Click the “Start” button to upgrade the App firmware.
Step 2: Then firmware upgrade will be started.
Step 3: “PASS” will be shown on the interface after the firmware is successfully upgraded, as shown in the following figure. Then it is needed to restart the module manually.
Upgrade Core Firmware
Step 1: Click the “Start” button.
Step 2: Then firmware upgrade will be started.
Step 3: “PASS” will be shown on the interface after the firmware is successfully upgraded, as shown in the following figure. Then it is needed to restart the module manually.
Abnormalities
Abnormalities may be caused by incorrect parameters of baud rates, damaged EVB/TE-A or invalid files, etc. The following illustrates some common abnormalities.
Select a Wrong Serial Port
Connected to an Occupied Serial Port
Select an Invalid Load File
Power Supply is Abnormal