QUECTEL Coolwatcher IoT Module User Manual
- June 2, 2024
- QUECTEL
Table of Contents
QUECTEL Coolwatcher IoT Module User Manual
Foreword
Suitable Condition
Tools | Manufacturer Revision | Applicable Module Type |
---|---|---|
Coolwatcher | AT+CGMI/RDA_89xx | BC25/BC32/BC35-GR/BC95-B5R/BC95-B8R/BC65/BC92 |
Related to Download
Coolwatcher
https://quectel123
my.sharepoint.cn/:u:/g/personal/aefae_dom_quectel_com_cn/EUj4DJB D9VJrsdRa-
DuIFYBTcNyLMrxoyu1EQgTvGShTA?e=QAqe4H
Device Connection
If the module has been welded or debugged separately, it is recommended that you connect to the Coolwatcher and grab the log as shown below. Note that the BC65/BC92 for overseas type, Tx/Rx and TTL_Tx/TTL_Rx directly connect, do not need to cross;
If TE-B corresponding to RDA module is used, from ”Device Manager → Ports” to select the second COM port(XR21V1412 USB UART ChB).
Coolwatcher
Coolwatcher is installation-free and can be used after decompression. Run coolwatcher_debughost.exe in the \cooltoolswin32_custom_P3.R2.0.0005 path.
Coolwatcher Connection
Before connecting the device, run the AT^TRACECTRL=1 via the main UART to enable debugging output. After capturing logs, to run AT^TRACECTRL=0 to disable debug output.
Click the Coolwatcher icon above, and then the configuration window as shown below pops up. Select “8910” for Profiles and the corresponding Debug port for lastcomport,then to click ”OK”;
The message shown below is output after the device is successfully connected.
Coolwatcher
Select “Plugins→Activate Tracer” from the menu bar, as shown below, and open the log trace window.
Select “Tracer→Set Trace Levels” from the menu bar, or select all log types, and to select “Save Pcap”. Then to click OK;
Choose “Tracer→Start Tracer/Stop Tracer” in the menu bar, or the icon as shown below, to Start tracing logs or Stop tracing.
Save Log
Automatically Save
Select “Tracer→Set Trace Levels” in the menu bar, or the icon as shown below, select Auto Save, and Set the save path. By default, log path \coolTools- win32_custom_p3.r2.0.0005 \logs; Where \ cooltools-win32_custom_p3.r2.0.0005 \logs\cap is saved as Pcap file;
Manual save
You can also choose“Tracer→Save”Trace from the menu bar, or Save the log as shown below.
Common Analytical Application
Import Log
Currently Notepad++ or UltraEdit is commonly used to view or analyze the Log;You can also import logs using Coolwatcher; On the menu bar, choose “Tracer→Load Trace (bin)” and select the corresponding xxx.bin file
LOG Filter Log
Coolwatcher Log filter as shown below, input filtering keywords then press Enter,and support the use of a single vertical bar the regular filtering;
Common filtering keyword
Camp Cell| cell search|Servcell frequency|ServingRSRP
---|---
AT Command| AT CMD0
NAS/AS message| EventReport|NAS:data
Data Analysis| AT
CMD0|RAB:rab03|NAS:esm03|NAS:esm11|NAS:esm10|NAS:emm00|EventReport|NAS:data
|errc06_26|errc00_32|cpDataCnfCount|CFN:
Pcap(Output Pcap)
Select “Tracer→Set Trace Levels” from the menu bar, and to select “Save Pcap”. Then to click OK; Pcap Default save\ path\cooltools- win32_custom_P3.R2.0.0005\logs\cap; Pcap can be analyzed using Wireshark for data interaction
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>