Product Settings
Power Supply
The DC power that operates the RED TAB is supplied with 5V from USB Type-C.
GUI Control
The RED Utility helps the user to start working with RED DK RFID reader
quickly.
Follow below steps to run GUI.
Windows Start button ➔ Program Menu ➔ RED Utility_vX.X.X
_ Figure 1 RED Utility_vX.X.X_
Mode Change
RED Utility provides two view modes. User can select view mode depending on
purpose of use between Basic View Mode and Extended View Mode.
Figure 2 Basic View Mode
To change View Mode, click the extension button marked red in Figure 7 above.
Figure 3 Extended View Mode
Always use Extended View Mode for measurement
RED TAB Connection
If hardware connection is valid, RED utility connect module REDx automatically.
If utility cannot connect hardware, please follow below step
Click “Connection->Connect” to connect to REDx-DK through USB-to-UART at main
window GUI will find the Device and synchronize parameters with REDx module
automatically. If the GUI cannot find the device automatically, Click
“Connection->Port Setting” and select other Device. Default Baud rate is
115200 bit/s.
If the Device connected successfully, status bar will display “OPEN” state and
device number and so on.
Hardware Control
Click ‘H/W Control Tab.’ To control hardware.
Band(Region) Setting
To select operating band, band setting should be required. Select band in
combo box and click Set button to set operating band in group box ‘Frequency
Control.
Power Class Setting
Some countries classify channel number by power class. Click Get button and
choose required power class. And then click Set button to set finally.
Output Power setting
To set RED output power, select the Output Power combo box and click Set
button.
CW (Continuous Wave) setting
It is only used for hardware debugging.
To set CW on, click Turn Tx CW on button. To set CW off, click Tx CW off
button.
Tag Inventory Procedure
Click Start button in Tag Information Tab to read UHF RFID tag with RED
Utility.
Click Start button and Tag’s EPC information is displayed.
Specification
No.| Item| Unit| Test Condition| Specification|
Remark
---|---|---|---|---|---
min| Typ.| max
1| Frequency Range| MHz| –| 917.1| –| 926.9| –
2| Tx Power| dBm| –| –| 25| –| –
3| Spurious| dBm| –| US (FCC 15C)| –
4| DC Power| V| —| –| –| 5| –
5| Operating Temperature| °C| –| -20| –| 70| –
6| Operating Humidity| %| –| 0| –| 90| –
7| Current| Power Down| uA| Active current is measured at 25dBm with 50ohm
load| –| –| –| –
Idle| mA| –| —| –
Active| –| –| –
8| Size| mm| 150 150 10.7| –
9| Weight| g| –| –
- Device Name(Model Name) : RED TAB
- FCC ID: Y3D-REDTAB
- Name of Grantee: PHYCHIPS Inc.
- Production year, month, date:
- Manufacturer/Country: Korea
FCC Information to User
This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions:
- the device may not cause interference, and
- the device must accept any interference, including interference that may cause undesired operation of this device.
Caution : Any changes or modifications in construction of this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment This device generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technical for help.
End Product Labeling
The module is labeled with its own FCC. If the FCC ID is not visible when the
module is installed inside another device, then the outside of the device into
which the module is installed must also display a label referring to the
enclosed module. In that case, the final end product must be labeled in a
visible area with the following: “Contains FCC ID: Y3D-REDTAB”
OEM Responsibilities to comply with FCC
The module has been certified for integration into products only by OEM
integrators under the following condition:
- The antenna(s) must be installed such that a minimum separation distance of at least 20 cm is maintained between the radiator (antenna) and all persons at all times.
- The module is limited to installation in mobile or fixed applications.
- The transmitter module must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures.
- Separate approval will be required for all other operating configurations, including portable configurations with respect
to Part 2.1093 and different antenna configurations other than supplied antennas.
As long as the condition above is met, further transmitter testing will not be
required. However, the OEM integrator is still responsible for testing their
end-product for any additional compliance requirements required with this
module installed (for example, digital device emissions, PC peripheral
requirements, etc.).
In the event that these conditions cannot be met, then the FCC authorizations
are no longer considered valid and the FCC ID cannot be used on the final
product. In these circumstances, the OEM integrator will be responsible for
reevaluating the end product including this module and obtaining separate FCC
authorizations.
- This device is intended only for OEM integrators.
- For OEM integration only – device cannot be sold to general public.
- Manual Information to the End User.
The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module.
This device may only operate using an antenna of a type and maximum (or
lesser) gain approved by Phychips. Antenna
types not included in the list, having a gain greater than the maximum gain
indicated for that type, are strictly prohibited for use with this
transmitter.
Note
| Peak Gain| Part Name
---|---|---
ANT| -1.61| QFFA4010G150