Hunter 51744 Beck 52-Inch Ceiling Fan Installation Guide
- June 6, 2024
- Hunter
Table of Contents
- Beck
- Here are the tools you’ll need to complete your installation:
- Here is what comes in your box:
- Choosing the Right Installation Location
- Checking the Ceiling Angle:
- Angled Mounting
- Installing the Ceiling Bracket
- Installing the Downrod
- Hanging the Fan
- Wiring the Fan
- Installing the Canopy
- Installing the Blades:
- Assembling the Light Kit
- Light Kit
- Installing the Pull Chains
- Reversing the Fan
- Troubleshooting
- Limited Lifetime Warranty
- Downrod
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Beck
Installation Manual
©2020 Hunter Fan Co. PG3782 r100821
Model: 51744 Fresh White
54214 Brushed Nickel
54215 Matte Black
Fan weight ±2 lbs: 21.8 lbs (9.9 kg)
Congratulations on purchasing your new Hunter® ceiling fan!
The ceiling fan you purchased will provide comfort and performance in your home or office for many years. This instruction manual contains complete instructions for installing and operating your fan. We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world.
We are here to help!
This Instruction Manual is designed to make installation as simple as possible. While working through this Instruction Manual, keep your smartphone or tablet nearby. We have added video links to help you through the more technical sections. If you are unfamiliar or uncomfortable with wiring, contact a qualified electrician. We also provide telephone support at 1.888.830.1326 or visit us at HunterFan.com.
READ and SAVE These Instructions
WARNING
Warning
w.1 – To reduce the risk of fire, electrical shock, or personal injury, mount
fan directly from building structure and/or an outlet box marked acceptable
for fan support of 70 lbs (31.8 kg) and use the mounting screws provided with
the outlet box.
w.2 – To avoid possible electrical shock, before installing or servicing your
fan, disconnect the power by turning off the circuit breakers to the outlet
box and associated wall switch location. If you cannot lock the circuit
breakers in the off position, securely fasten a prominent warning device, such
as a tag, to the service panel.
w.3 – To reduce the risk of electric shock, this fan must be installed with an
isolating wall control/switch.
w.4 – To reduce the risk of personal injury, do not bend the blade brackets
when installing the blade brackets, balancing the blades, or cleaning the fan.
Do not insert foreign objects in between rotating fan blades.
Caution
c.1 – All wiring must be in accordance with national and local electrical
codes ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified
electrician.
c.2 – Use only Hunter replacement parts.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and if not installed and used in accordance with the
instructions may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution: modifications not approved by the party responsible for compliance
could void user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This product conforms to UL Standard 507.
Here are the tools you’ll need to complete your installation:
Ladder Screwdriver
Pliers Wire Strippers
OPTIONAL
If mounting to a support structure, you will also need these tools.
Drill 9/64” Drill Bit
© 2020 Hunter Fan Company
7130 Goodlett Farms Pkwy, Suite 400
Memphis TN 38016
Here is what comes in your box:
We recommend that you pull everything out of the box and lay it out. We have grouped the drawn components below with the hardware you’ll need for those parts. The screws below are drawn to scale to make it easier to identify what piece of hardware is needed to install each component.
Hunter Pro Tip:
Do not discard the hardware bags or mix parts from different bags. Make note of the symbol printed on each hardware bag. The symbols can be used to identify the appropriate hardware for each step.
x2
BAG Wood Screw
Washer x2 Wire Nut x4
For installing the hanger bracket and wiring the fan
Ceiling Bracket
![Hunter 51744
- Accessories 3](https://manuals.plus/wp- content/uploads/2022/04/Hunter-51744-Accessories-3-550x361.png)
Blade Arm x4
![Hunter 51744
- Accessories 4](https://manuals.plus/wp- content/uploads/2022/04/Hunter-51744-Accessories-4-550x364.png)
Blade x4
For installing the blades
Pullchains and extra downrod
BAG Spare Parts
For your convenience, you may receive extra fasteners.
x3 x2
BAG Light Kit Screw Short Light Kit Screw
Motor
Light Kit Assembly
Switch Housing Plate
Bulb x2
Globe
Globe Retainer
For installing the light fixture
Find a part that is missing or damaged?
Don’t take it back to the store. Let us make it right. Visit us at
HunterFan.com or call us at 1.888.830.1326.
M3753-01 r080620
Choosing the Right Installation Location
You probably bought this fan with a location in mind. Let’s check below to make sure it is a good fit.
Check the room dimensions: Check the outlet box:
You must be able to secure the fan to building structure or fan-rated outlet box.
Checking the Ceiling Angle:
Standard Mounting
If you have a flat ceiling:
Hang your fan by a standard downrod. Some fans come with a shorter downrod for
a Low Profile installation.
If you have an angled or vaulted ceiling:
- You will need a longer downrod. (sold separately at HunterFan.com)
- If your ceiling angle is greater than 34°, you will also need an Angled Mounting Kit. (Sold separately at HunterFan.com)
Angled Mounting
A little more information on Angled Mounting:
For optimum performance and appearance, a longer downrod should be used with your Hunter ceiling fan when installing on high or angled ceiling. If your ceiling is angled greater than 34° you will also need an Angled Mounting Kit. Longer downrods and the Angled Mounting Kit are sold separately at HunterFan.com.
Hunter Pro Tip:
Determining if you need an Angled Mounting Kit:
Fold on the dotted line. Place edge against the wall. Slide towards the
ceiling.
If the guide touches the wall but not the ceiling, you need an angled mounting
kit.
Installing the Ceiling Bracket
You have two options for installation. Pick which one works best for your location. Remove any existing bracket prior to installation. Only use the provided Hunter ceiling bracket that came in your fan’s box.
Do this first!
To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location.
Option 1:
Machine Screws
Use machine screws (provided with outlet box) and washers when securing to existing ceiling fan-rated outlet box. Make sure it is securely installed and is acceptable for fan support of 31.8 kg (70 lbs) or less.
ANGLED MOUNTING TIP
For angled ceilings, point opening toward peak.
Option 2:
Wood Screws
Use wood screws and washers (included) when securing to support structure with approved electrical outlet box. Drill 9/64” pilot holes in support structure to aid in securing ceiling bracket with hardware found in the hardware bag.
Hunter Pro Tip:
The machine screws are the ones that came with your outlet box.
Installing the Downrod
Follow below if you are using the downrod that came pre-assembled in your box. Need to install a longer or shorter downrod? Check out the guide at the end of this manual.
Remove the pre-installed setscrew so that the downrod can be inserted.
Hunter Pro Tip:
The ground wire attached to the downrod is approximately 8 inches.
Pass all wires to one side of horizontal bar in downrod assembly. Hand tighten the downrod (at least 4–5 full turns) until it stops. Trim the wires coming from the fan so that 8-inches remain coming from the top of the downrod.
Tighten the setscrew with pliers. DO NOT HAND TIGHTEN.
FAN FALL HAZARD
To prevent SERIOUS INJURY or DEATH:
- ALWAYS tighten setscrew with pliers.
- DO NOT hand tighten setscrew.
- CHECK the setscrew is tight using pliers each time you change fan direction.
Hanging the Fan
NOTICE
To prevent damage to fan, ALWAYS lift holding either the fan housing or the
downrod.
Place the downrod ball into the slot in the ceiling bracket.
Progress Check:
Your fan should look like this.
Wiring the Fan
We know wiring is hard. Let’s make it easier.
Follow these steps to get your fan wired quickly and safely. Follow the route below that best matches your wall switch setup. If you are unfamiliar with wiring or uncomfortable doing it yourself, please contact a qualified electrician.
You are going to need these:
4 Wire Nuts (these are in the bag)
Hunter Pro Tip:
Here is how to connect the wires:
Push the bare metal ends of the wires together and slide a wire nut over them.
Then, twist the wire nut clockwise until tight.
Give it a gentle pull to make sure none of the wires are loose.
Have a single switch?
Follow these steps:
- Connect the black wire (ungrounded) from the ceiling to the black and the blue wires from the fan.
- Connect the white (grounded) wire from the ceiling to the white wire from the fan.
- Connect the three grounding wires (green, green/yellow stripe, or bare copper) coming from the ceiling, downrod, and hanging bracket.
The ceiling fan must be grounded. If the ground wire for the installation site is not present, immediately STOP installation and consult a qualified electrician.
All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring or in doubt, consult a qualified electrician.
Hunter Pro Tip:
Have extra wiring?
Turn the wires upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one
side of the outlet box and the ungrounded wires on the other side of the
outlet box. Make sure that the wires are still attached to the wire nuts.
Have dual switches?
Follow these steps:
- Connect the three grounding wires (green, green/yellow stripe, or bare copper) coming from the ceiling, downrod, and hanging bracket.
- Connect the second ungrounded (light) wire from the ceiling to the blue wire from the fan.
- Connect the black (ungrounded) wire from the ceiling to the black wire from the fan.
- Connect the white (grounded) wire from the ceiling to the white wire from the fan.
Installing the Canopy
- Lift the canopy into place so that the screw holes are aligned.
Hunter Pro Tip:
Let the tool do the work!
A magnetic screwdriver will give you more visibility when securing the canopy.
Insert the two canopy screws found in the hardware bag.
Installing the Blades:
Put the blade washers, found in the hardware bag, onto the blade screws, found
in the hardware bag. Then install the blade screws to secure each blade to a
blade iron.
Repeat x4
Lightly attach the blade arms to the motor with screws found in the hardware
bag, then securely tighten after both screws are attached.
Repeat x4
NOTE: The blade arms should be mounted with the ridge facing downward. Installing it incorrectly could result in your fan not functioning.
Assembling the Light Kit
Partially install two light kit assembly screws, found in the hardware bag, halfway into the motor housing as shown. It does not matter which two screw holes you choose.
Feed the 9-pin plug connector coming from the bottom of the motor housing through the center hole in the light kit assembly. Connect it to the plug connector found in the switch housing area of the light kit assembly. Make sure to line up the colored markings on the connectors.
Align the keyhole slots in the top of the light kit assembly with the partially installed assembly screws. Wrap the keyhole slots around the screws and twist counterclockwise.
Insert the third screw, found in the hardware bag, in place and firmly tighten all the three screws.
Carefully push all switch housing components into the switch housing, then install the switch housing plate using two short light kit assembly screws, found in the hardware bag.
FAN FALL HAZARD
Make sure all screws are tight to secure the light fixture.
Light Kit
Install a bulb into each of the sockets. When necessary, replace with bulbs of the same wattage.
Repeat x2
Align the globe indentations with the globe retainer screw holes and carefully lower the globe into the globe retainer until it rests in place.
Lift the globe assembly and attach it to the upper switch housing using the four thumbscrews. Tighten all four screws securely by hand.
GLASS FALL HAZARD
To prevent SERIOUS INJURY or DEATH, make sure that glass is properly secured.
Installing the Pull Chains
-
Feed the pull chains from the fan switch and the light switch down through the holes in the upper switch housing as shown. Attach the pull chain pendants to the light and fan pull chains.
Repeat x2 -
The light pull chain controls the light fixture: on and off.
-
The fan pull chain controls the speed: from high to off.
Reversing the Fan
- Ceiling fans work in two directions: downdraft (counterclockwise rotation) and updraft (clockwise rotation). To change the direction of air flow, turn the fan off and let it come to a complete stop. The reversing switch is located inside the light fixture. It can only be accessed when the glass is removed. Slide the reversing switch to the opposite position. Restart the fan.
- Updraft (clockwise rotation) creates a more indirect airflow. Updraft airflow is great for moving warm air downward.
- Downdraft (counterclockwise rotation) creates a direct breeze and maximum cooling effect.
Troubleshooting
Fan Doesn’t Work
- Make sure power switch is on.
- Check the circuit breaker to ensure the power is turned on.
- Make sure the blades spin freely.
- Turn off power from the circuit breaker, then loosen the canopy and check all the connections according to the wiring diagram.
Excessive Wobbling
- Make sure the blades are properly installed on the blade iron posts.
- Turn the power off, support the fan carefully, and check that the hanger ball is properly seated.
- Use the provided balancing kit and instructions to balance the fan.
Noisy Operation
- Make sure the blades are properly installed.
- Check to see if any of the blades are cracked. If so, replace all of the blades.
Hunter Pro Tip:
Cleaning the Fan
Use soft brushes or cloths to prevent scratching. Cleaning products may damage
the finishes.
Limited Lifetime Warranty
Hunter Fan Company grants this limited warranty to the original purchaser of
this Hunter ceiling fan. This document can be found at
www.HunterFan.com.
Thank you for choosing Hunter!
How Can Warranty Service Be Obtained?
Proof of purchase is required when requesting warranty service. The original purchaser must present a sales receipt or other document that establishes proof of purchase. Hunter, at its sole discretion, may accept a gift receipt. To obtain service, contact Hunter Fan Company online or by phone.
www.HunterFan.com/Support/Contact-Us/
1-888-830-1326
Please do not ship your fan or any fan parts to Hunter. Delivery will be refused.
What Does This Warranty Cover?
Motor — Limited Lifetime Warranty
If any part of your ceiling fan motor fails during your ownership of the fan due to a defect in material or workmanship, as determined solely by Hunter, Hunter will provide you with a replacement fan free of charge.* The foregoing limited warranty applies only to the motor itself and does not apply to electronic controls - such as remote control transmitters, remote control receivers, or capacitors - used in conjunction with the motor. Such electronic control items are included in the one-year limited warranty below.
Other — One-Year Limited Warranty
Except as otherwise indicated throughout this warranty, if any part of your Hunter ceiling fan fails at any time within one year of the date of purchase due to a defect in material or workmanship, as determined solely by Hunter, Hunter will provide a replacement part free of charge.*
Light Kits — Warranty May Vary
Light kits are included in the one-year limited warranty. However, you may qualify for additional warranty coverage if your fan includes one of the following:
-
LED Light Kits — Three-Year Limited Warranty
If your LED light kit module (not including glass components) or LED bulb fails at any time within three years of the date of purchase due to a defect in material or workmanship, as determined solely by Hunter, Hunter will provide a replacement part free of charge.* -
If no replacement product/part can be provided for your fan, we will provide a comparable or superior replacement product/part at the sole discretion of Hunter.
What Does This Warranty NOT Cover?
Labor Excluded. This warranty does not cover any costs or fees associated with
the labor (including electrician’s fees) required to install, remove, or
replace a fan or any fan parts. There is no warranty for light bulbs (except
where otherwise noted); remote control batteries; fans purchased or installed
outside the United States; fans owned by someone other than the original
purchaser; fans for which proof of purchase has not been established; fans
purchased from an unauthorized dealer; ordinary wear and tear; minor cosmetic
blemishes; refurbished fans; and fans that are damaged due to any of the
following: improper installation, misuse, abuse, improper care, failure to
follow Hunter instructions, accidental damage caused by the fan owner or
related parties, modifications to the fan, improper or incorrectly performed
maintenance or repair, improper voltage supply or power surge, use of improper
parts or accessories, failure to provide maintenance to the fan, or acts of
God (e.g. flood).
ORIGINAL PURCHASER’S SOLE AND EXCLUSIVE REMEDY FOR A CLAIM OF ANY KIND WITH
RESPECT TO THIS PRODUCT SHALL BE THE REMEDIES SET FORTH HEREIN. HUNTER FAN
COMPANY IS NOT RESPONSIBLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, DUE TO
PRODUCT FAILURE, WHETHER ARISING OUT OF BREACH OF WARRANTY, BREACH OF
CONTRACT, OR OTHERWISE. Some States do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation or exclusion
may not apply to you.
ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
APPLICABLE TO THIS PRODUCT ARE LIMITED IN DURATION TO THE PERIOD OF COVERAGE
OF THE APPLICABLE LIMITED WARRANTIES SET FORTH ABOVE. Some States do not allow
limitations on how long an implied warranty lasts, so the above limitation may
not apply to you.
How Does State Law Affect Warranty Coverage?
This warranty gives you specific legal rights. You may also have other rights which vary from state to state.
Downrod
If you need a different downrod length follow these steps:
Follow steps 1-5 to remove standard downrod pipe
Follow steps 6-10 to reassemble with new downrod
Here is another view of the downrod assembly unassembled.
Assembled downrod should look like this
FAN FALL HAZARD
To prevent SERIOUS INJURY or DEATH :
- ALWAYS follow the downrod assembly instructions exactly.
- VERIFY the downrod is assembled correctly by firmly pulling on the hanger ball.
- Pin must be reinserted to secure downrod assembly.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>