DSC HS2LED Electronic Keypad Instruction Manual
- June 9, 2024
- DSC
Table of Contents
- DSC HS2LED Electronic Keypad
- Introduction
- Specifications
- Unpack
- Mount the Keypad
- Mount and Wire Keypad
- Wiring
- Apply Power
- Program the Keypad
- Language Programming
- Enroll the Keypad
- Program Labels (LCD keypads)
- Label Library
- Change Brightness/Contrast/Buzzer
- Keypad Programming
- Keypad Symbols
- Proxi m ity (Prox) Tags Support (HS2ICNP/HS2ICNRFP/HS2LCDP)
- Troubleshooting
- Word Library
- Limited Warranty
- FCC Compliance Statement
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DSC HS2LED Electronic Keypad
WARNING: Please refer to the System Installation Manual for information
on limitations regarding product use and function and information on the
limitations as to liability of the manufacturer.
NOTE: These instructions shall be used in conjunction with the system
Installation Manual of the Control Panel with which this equipment is intended
to be used..
Introduction
The HS2LED/HS2ICN(P)(RF)x/HS2LCD(RF)(P)x keypads are compatible with the
PowerSeries Neo HS2016/32/64, HS2014-4 and HS2128 panels. The RF keypads
combine a wireless trans-ceiver with the respective HS2 keypad.
Model not UL/ULC listed.
Specifications
- Temperature range: -10°C to +55°C (14°F to 131°F); UL/ULC: 0°C to +49°C (32°F to 120°F)
- Humidity (MAX): 93%R.H. non-condensing
- Plastic enclosure protection degree: IP30, IK04
- Voltage rating: 13.8Vdc nominal (power provided by the compatible control panel)
- Connects to control panel Corbus via 4 wires
- configurable zone input or PGM output*
HS2LED/ HS2ICN (P) /HS2LCD (P) /HS2ICNRF (P) /HS2LCDRF(P)
- Current draw:55mA(min)/105mA(max)
- Wall-mount tamper
- 5 programmable function keys
- Ready (Green LED), Armed (Red LED), Trouble (Yellow LED), AC (Green LED)
- Dimensions (L x W x D): 168mm x 122mm x 20 mm
- Weight: 260g
- Low temperature sensor
- Frequency: 433 MHz (HS2ICNRF4/HS2LCDRF4)
- 868 MHz (HS2ICNRF8/HS2LCDRF8)
- 912-919MHz (HS2ICNRF9/HS2LCDRF9)
- Up to 128 wireless zones
Zone not to be programmed as Fire type or 24h type.
NOTE: Keypads contain no serviceable parts.
NOTE: Only models operating in band 912-919MHz are UL/ULC listed.
Unpack
The keypad package includes the following:
HS2LED/ICN(RF)/LCD(RF) HS2ICN(RF)P/LCD(RF)P
- keypad
- 1 keypad
- 4 mounting screws
- 4 mounting screws
- 2 end-of-line resistors
- 2 end-of-line resistors
- Keypad inner door labels Keypad inner door labels
- 1 tamper switch
- 1 tamper switch
- Installation Instructions
- Installation Instructions
- Mini Proximity (prox) tag (MPT)
Table 1: Compatible Devices
Wireless PG smoke detector | PGx926UL |
---|---|
Wireless PG smoke and heat detector | PGx916UL |
Wireless PG CO detector | PGx913 |
Wireless PG PIR motion detector | PGx904(P)UL |
Wireless PG PIR + camera motion detector | PGx934(P)UL |
Wireless PG curtain motion detector | PGx924UL |
Wireless PG dual tech motion detector | PGx984(P) |
Wireless PG mirror motion detector | PGx974(P)UL |
Wireless PG outdoor motion detector | PGx994UL |
Wireless PG glass break detector | PGx912 |
Wireless PG shock detector | PGx935UL |
Wireless PG flood detector | PGx985UL |
Wireless PG temperature detector (indoor) | PGx905UL |
Outdoor temperature probe (requires PGx905) | PGTEMP-PROBE |
Wireless PG key | PGx939UL |
Wireless PG key | PGx929UL |
Wireless PG panic key | PGx938UL |
Wireless PG 2-button key | PGx949UL |
Wireless PG indoor siren | PGx901UL |
Wireless PG outdoor siren | PGx911UL |
Wireless PG repeater | PGx920UL |
Wireless PG door/window contact | PGx975UL |
Wireless PG door/window contact w/AUX | PGx945UL |
NOTE: In this chart, x in the model number represents the oper-ating
frequency of the device as follows: 9 (912-919 MHz), 8 (868MHz), 4 (433MHz).
NOTE: Only models operating in the band 912-919 MHz are UL/ULC or cUL
listed where indicated. Only UL approved devices are to be used with UL/ULC
listed systems.
Mount the Keypad
Mount the keypad where it is accessible from designated points of entry and exit. Once a dry and secure location has been selected, perform the following steps to mount the keypad.
Disassemble Keypad
Insert the tip of a flat-head screwdriver into the slots at the bottom left
and right of the keypad.
Gently pry open the faceplate. This will remove it and allow access for
mounting.
Mount and Wire Keypad
-
Secure keypad to wall using mounting holes. Use all four screws provided unless mounting on a single gang box. Use the plastic anchors supplied if the unit is to be mounted on drywall.
-
If using the keypad tamper, secure the tamper plate to the wall with a screw.
NOTE: For UL/ULC listed commercial burglary installations, the use of the keypad tamper is mandatory. -
Run wire through wiring slot or knockouts. Connect Corbus and PGM/Zone wiring to keypad. Place tamper switch into tamper hole on backplate.
-
Place keypad into backplate, ensuring the wire is pushed back into the wall as much as possible. Route the wire inside the keypad, ensuring high components are avoided. Snap the front assembly closed, ensuring that there is no pressure to the keypad from the wire below.
NOTE: If any tension is found between the front keypad assembly and the wiring, open the keypad, reroute the wire and close again. Repeat these steps until the keypad is closed properly.
Wiring
-
Before wiring the unit, ensure that all power (AC transformer and bat-tery) is disconnected from the con-trol panel.
-
Connect the four Corbus wires from the control panel (red, black, yellow and green) to the keypad ter-minals. Refer to the diagram:
If programmed as an input, a device – such as a door contact – may be connected to the ‘P/Z’ terminal of the keypad. This eliminates the need to run wires back to the control panel for the device. To connect the zone, run one wire from the device to the ‘P/Z’ terminal and the other wire from the device to the B (black) terminal. For powered devices, run the red wire to the R (positive) terminal and the black wire to the B (neg-ative) terminal. When using end of line supervision, connect the zone according to one of the configurations described in the Power-Series Neo Reference manual.
NOTE: For UL/ULC installations, the zone input is a supervised type (SEOL/DEOL). The supervision resistor is 5600Ω. If no EOL supervision is used, there is a three foot maximum distance required for the connected device. Use only in conjunction with UL/ULC listed devices.
NOTE: This initiating device connected to this input contact is not to be used for medical or fire applications. -
If the ‘P/Z’ terminal is programmed as an output, a small relay (such as DSC model RM-1 or RM-2) or buzzer or other DC oper-ated device may be connected between the positive supply voltage and the ‘P/Z’ terminal (max.load is 50mA).
NOTE: For UL/ULC-listed installations, use UL/ULC listed devices.
Apply Power
Once all wiring is complete, and the equipment is secured to the building structure with at least two screws, apply power to the control panel:
- Connect the battery leads to the battery.
- Connect the AC transformer.
For more information on control panel power specifications, see the PowerSeries Neo Reference manual.
Program the Keypad
- Press [*][8][Installer Code].
- Use the [<][>] keys to nav-igate through the menus or jump directly to a specific section by entering the section number. Programming consists of tog-gling on and off options in each section or by populating data fields. Toggle options are enabled or disabled by pressing the corresponding number on the keypad. For example, to enable toggle options 1 and 4, press the[1] and [4] keys.
All enabled options are displayed (see the following diagram).
- To input data, use the [<][>] keys to select a character then press the keypad button for the number/letter.
- Using the [<][>] keys, scroll to the next character and repeat the procedure. For information on entering HEX data, refer to the PowerSeries Neo Reference manual.
Language Programming
Enter [000][000]. Enter the two-digit number corresponding to the language desired:
Table 2: Languages
01 = English (default) | 10 = German | 20 = Romanian |
---|---|---|
11 = Swedish | 21 = Russian | |
02 = Spanish | 12 = Norwegian | 22 = Bulgarian |
03 = Portuguese | 13 = Danish | 23 = Latvian |
04 = French | 14 = Hebrew | 24 = Lithuanian |
05 = Italian | 15 = Greek | 25 = Ukrainian |
06 = Dutch | 16 = Turkish | 26 = Slovak |
07 = Polish | 17 = FFU | 27 = Serbian |
08 = Czech | 18 = Croatian | 28 = Estonian |
09 = Finnish | 19 = Hungarian | 29 = Slovenian |
Enroll the Keypad
Keypads can be enrolled automatically or manually. In either case, the serial
number of the device is used as an identifier.
NOTE: If there is no keypad enrolled on the system, once you power up,
the keypad will display the message: Press any key to enroll. Other keypads
can then be enrolled from the first keypad. Use one of the following
enrollment options:
[902][000] Auto Enroll
When this mode is selected, the total number of keypads currently enrolled is displayed on the keypad.
- Enter [902][000] to begin the auto-enrollment of new keypads.
- As each device is enrolled, the keypad displays the model type, serial number and slot assignment. Keypads are assigned to the next available slot.
[902][001] Manual Enroll
To manually enroll individual keypads:
- Enter [902][001] or use the [<][>] keys and press [*].
- When prompted, enter the serial number of the keypad found on the back of the device.
- An error tone is sounded if an invalid serial number is received. Once enrolled, the device model, serial number and slot assign-ment are displayed. Keypads are enrolled into the next available slot for the device. The slot assignment can be changed using the [<][>] keys.
- To cancel the enrollment of a module, press [#].
NOTE: Once the maximum number of devices have been enrolled, an error tone sounds and a warning message is displayed.
[902][002] – Module Slot Assignment (LED, LCD, ICON)
This section is used to change the slot number in which a module is enrolled. To change the slot number:
- Enter [902][002] or use the [<][>] keys and press [*].
- Enter the serial number of the module.
- When prompted, enter the new two-digit slot number. The pre-vious slot assignment is replaced with the new one. An error tone sounds if an invalid slot number is entered.
[902][003] – Module Slot Assignment (LCD Only)
Similarly to [002], this section is also used to change the slot num-ber of a module. With this option, however, the serial number is not required. To change the slot number:
- Enter [902][003] or the use the [<][>] keys and press [*].
- Use the [<][>] keys to locate the module then press [*] to select.
- Enter the new two-digit slot number. The previous slot assignment is replaced with the new one. An error tone sounds if an invalid slot number is entered.
[902][101] Unenroll Keypads
- Enter [902][101] or use the [<][>] keys and press [*].
- Use the [<][>] keys to scroll to the specific keypad to delete.
- Press [] to select the module and when prompted, press [] again to delete it.
[903][101] Confirm Keypad
To confirm the enrollment of individual keypads and to locate them physically:
- Enter [903][101] or use the [<][>] and press [*].
- Use the [<][>] keys to scroll to the applicable keypad. The mod-ule’s serial number and slot number are displayed on the keypad and the status LEDs on the device flash.
- To confirm the keypad, press [*]. If communication with a mod-ule is lost at the time of confirmation, a warning message is dis-played for 1 second before exiting the section.
Assign a Partition to the Keypad
The keypad must be assigned to a partition if supervision or keypad zones are
required. Keypad assignments and keypad option programming must be done at
each keypad individually.
At each keypad installed on the system:
-
Press [*][8][Installer Code].
-
Enter [861]-[876] for Keypad Programming and Keypad Partition Mask, corresponding to keypads 1-16.
-
Press [*] for partition assignment.
-
Enter 01 to 08 for partition assignment or use the [<][>] keys to scroll to the specific partition If partitioning is not used, enter
[01]. For Global keypads, enter [00]. -
Press [#] twice to exit programming.
-
Continue this procedure for each keypad until all have been assigned to the correct partition.
Program Labels (LCD keypads)
- Press [*][8][Installer Code].
- Press [] and use the [<][>] keys to scroll to Zone Labels and press [] again.The first zone is dis-played. Alternatively, enter, [000][001].
- Use the [<][>] keys to scroll to the zone label to be programmed and press [*] or enter the zone num-ber (e.g., 001, for zone label 1).
- Use the [<][>] keys to scroll to the desired character’s location, using the [<][>] keys.
- Enter the number of the corresponding character group until the desired character is displayed (see the following table). Example, press the “2” key three times to enter the letter “F”. Press the “2” key four times to enter the number “2”. Press [], then scroll to “Save”. Press [] again to save the label. To delete a character, use the [<][>] keys to move the cursor under the character, then press [0]. If any key other than [<][>] is pressed before [0], the cursor moves one space to the right and deletes that character.
[1] – A, B, C, 1 | [5] – M, N, O, 5 | [9] – Y, Z, 9, 0 |
---|---|---|
[2] – D, E, F, 2 | [6] – P, Q, R, 6 | [0] – Space |
[3] – G, H, I, 3 | [7] – S, T, U, 7 | [*] – Select |
[4] – J, K, L, 4 | [8] – V, W, X, 8 | [#] – Escape |
CHANGE CASE – Will toggle the next letter entries between upper case (A, B,
C…) and lower case letters (a, b, c…).
ASCII ENTRY – Used to enter uncommon characters. Valid entries range from 000
to 255. Use the [<][>] keys to scroll through the characters or enter a
3-digit number from 000-255. Press [*] to enter the character into the label.
CLEAR TO END – Clears the display from the character where the cursor was
located to the end of the display.
CLEAR DISPLAY – Clears the entire label.
Continue from Step 2, until all labels are programmed.
Label Library
The Label Library is a database of words commonly used when programming
labels. Individual words can be combined as needed (e.g., Front + Door). Each
line of the display supports a maximum of 14 characters. If a word will not
fit on a line, scroll right until the cursor appears at the first character of
the second line and then add the word.
To program a custom label using the Label Library:
- Press [*][8][Installer Code][000][001].
- Enter [001] (to program the label for zone 01), or use the [<][>] keys to scroll to the Zone Labels and then press [*]. The current label name is displayed for that zone.
- Press [*] to open the menu.
- Press [*] again to select the “Word Entry” option.
- Enter the 3-digit number corresponding to a word (see Words Library) or use the [<][>] keys to view words in the library.
- Press [*] to select the word.
- To add another word, repeat the previous procedures from step 3.
- To add a space, press the right scroll key [>].
- To clear characters, select “Clear to End” or “Clear Display” from the menu.
- To save the current label and exit, press [#].
Broadcast LCD Labels
If more than one LCD keypad is present on the system, labels programmed on one
keypad will be broadcast to all other LCD keypads, after the change is
confirmed.
Change Brightness/Contrast/Buzzer
LCD Keypads
- Press [*][6][Master Code].
- Use the [<][>] keys to scroll to either Bright Control, Contrast Control, or Buzzer Control.
- Press [*] to select one of the following settings:
- Brightness/LED Bar Control -15 backlighting levels available.
- Contrast Control -15 display contrast levels available.
- Buzzer Control – 15 buzzer control levels available.
- Use the [<][>] keys to scroll to the desired setting.
Keypad Programming
- Press [*][8][Installer Code].
- Select one of the programming options identified in the following.
[860] Keypad Slot Number
Not for programming; the two-digit slot number is displayed for informational
purposes only.
[861]-[876] Keypad Programming Sections
[ 000] Address of Partition
Default: 01
A 2-digit entry is required to assign the keypad to a partition. Valid entries
are 00-32. NOTE: LED and ICON keypads must not be assigned as global keypads.
[001]-[005] Keypad Function Key Programming
To program a function key:
Press [*][8][Installer Code].
- Enter [861]-[876] for keypad programming.
- Enter [001]-[005] for function keys 1-5 or use the [<][>] keys and press [*].
- Enter a 2-digit number to assign a function key operation – [00]-[68]. See the following table.
- Repeat from step 3 until all function keys are programmed.
- Press [#] twice to exit Installer Programming.
Table 3: Function Key Assignment
| Function Key| Button| Valid Range| Default| Function|
---|---|---|---|---|---|---
[001]| Key 1|
| 00–68| 03| Stay Arm| || || |
[002]| Key 2| | 00–68| 04| Away Arm| || || |
[003]| Key 3| | 00–68| 06| Chime ON/OFF| || || |
[004]| Key 4| | 00–68| 22| Command Output 2| || || |
[005]| Key 5| | 00–68| 16| Quick Exit| || || |
Keypad Function Keys
Refer to your system installation manual for a complete list of available
function key options.
[00] Null | [02] Instant Stay Arm | [03] Stay Arm |
---|---|---|
[04] Away Arm | [05] [*][9] No-entry Arm | [06] [*][4] Chime ON/OFF |
[07] [*][6][—][04] System Test | [09] Night Arm | [12] Global Stay Arm |
[13] Global Away Arm | [14] Global Disarming | [16] [*][0] Quick Exit |
[17] Arm Interior | [21] [*][7][1] Command Output 1 | [22] [*][7][2] Command |
Output 2
[23] [][7][3] Command Output 3| [24] [][7][4] Command Output 4| [29] Bypass
Group Recall
[31] Local PGM Activate| [32] Bypass Mode| [33] Bypass Recall
[34] User Programming| [35] User Functions| [37] Time/ Date Program
[39] Trouble Display| [40] Alarm Memory| [61] – [68] Partition Select 1 – 8
[011] Keypad Input/Output Programming
Zone / PGM Number Default 000 |||_|
[012] Local PGM Output Pulse Activation Time
|___|| Minutes (00-99) ||___| Seconds (00-99)
[021] First Keypad Options
Default Opt. ON OFF
ON || 1 Fire Key Enabled Fire Key Disabled
ON || 2 Medical Key Enabled Medical Key Disabled
ON || 3 Panic Key Enabled Panic Key Disabled
ON || 4 Display Access Code When Programming
Display Xs When Programming
Access Codes
NOTE: For EN50131-1/EN50131-3 compliant systems, section [021], options 1 and
2 shall be OFF.
[022] Second Keypad Options
Default Opt. ON OFF
ON || 1 Local Clock Display ON Local Clock Display OFF
OFF || 2 Local Clock Displays 24-hr Clock Displays AM/PM
ON || 3 Auto Alarm Mem Scroll ON Auto Alarm Mem Scroll OFF
ON || 4 For Future Use For Future Use
OFF || 5 Power LED Enabled Power LED Disabled
ON || 6 Power LED AC Present ON Power LED AC Present OFF
ON || 7 Alarms Displayed While Armed Alarms Not Displayed While Armed
OFF || 8 Auto-Scroll Open Zones ON Auto-Scroll Open Zones OFF
[023] Third Keypad Options
Default Opt. ON OFF
OFF || 1 Armed LED Power Save Armed LED Off in Sleep Mode
ON || 2 Keypad Status Shows Stay Arm Keypad Status Shows Stay/Away Arm
OFF || 3 5th Terminal is PGM Output 5th Terminal is Zone Input
OFF || 7 Local Display of Temperature No Local Display of Temperature
OFF |____| 8 Low Temperature Warning Enabled Low Temperature Warning
Disabled
[030] Downloaded LCD Message
|||||||||||||||||
|||||||||||||||||
NOTE: Clock display (Section [022], Option 1) must be enabled.
[031] Downloaded LCD Message Duration
Default: 000 |||_____| (Valid entries are 000-255, 000=Unlimited Msg
Display)
This number represents the number of times the downloaded message must be
cleared before it is permanently
removed. This message can be cleared by pressing any key.
[041] Indoor Temperature Zone Assignment
Default: 000 |||_____| (Valid entries are 000-128)
[042] Outdoor Temperature Zone Assignment
Default: 000 |||_____| (Valid entries are 000-128)
[101]-[228] Door Chime for Zones
Default: 01 |||
The keypad can be programmed to make up to four different chime sounds for
individual zones.
(e.g., for Zone 1, enter section [101], for Zone 2 enter section [102]).
01 6 beeps 04 Alarm Tone (4s duration)
02 Bing bing tone 05 Zone Name
03 Ding dong tone
[991] Reset Keypad Programming to Factory Defaults
- Press [*][8][Installer Code].
- Enter [991].
- Use the [<][>] keys to scroll to the applicable keypad.
- Press [*] to select the keypad.
- Re-enter [Installer Code].
- Press [*] to reset the selected keypad to factory defaults
Keypad Symbols
Table 4: Keypad Display Symbols
| | | | | | | | | | |
---|---|---|---|---|---|---|---|---|---|---|---
1| Memory – Indicates
that alarms are in memory.| 10| Chime – Turns on when Door Chime is enabled
and off when Door Chime is disabled.
2| Fire – Indicates that fire alarms are in memory.| 11| Away – Indicates that
the panel
is armed in away mode.
3,4,5
| Clock Digits – These digits indicate the hour and minutes when the local
clock is active, and also identify the zone when the OPEN or ALARM icons are
active. These digits scroll one zone per second from the lowest zone number to
the highest when scrolling through zones.| 12| Stay – Indicates that the panel
is armed in stay mode.
13| Night – Indicates that the panel is armed in night mode.
6| 1 to 8 – These numbers display toggles or digits in binary while they are
needed.| 14| Ready Light (green) – If the Ready light is on, the system is
ready for arming.
7| Bypass – Indicates that there are zones auto- matically or manually
bypassed.| 15| Armed Light (red) – If the Armed light is on, the system has
been armed successfully.
8| Open – When zones are opened, this icon will turn on and the open zones are
displayed.| 16| System Trouble – Indicates that a system trouble is active.
9| Program – If the system is in Installer’s or User’s Programming, or the
keypad is busy, this icon flashes. If an access code is required while
accessing star menus, this LED is on steadily to indicate that the code is
required.| 17| AC – Indicates that AC is present at the main panel.
Proxi m ity (Prox) Tags Support (HS2ICNP/HS2ICNRFP/HS2LCDP)
The prox tag can perform any keypad function that would normally require a
user access code. Present
the tag to the tag reader ( ) or to the left of the keypad LCD.
Assign Proximity Tags
Using an LCD keypad:
- Press [*][5][Master/Supervisor Code].
- Enter a 2-digit user code.
- Press 2.
- Pass the enrolled tag near the tag reader on the keypad.
Delete Proximity Tags
To delete a prox tag, select the user as outlined previously.Swipe the
associated prox tag. The alarm system recognizes the tag. Press [*] to delete
when prompted.
LED Bar
On the HS2ICNP/HS2ICNRFP/HS2LCDP keypads, a blue LED bar indicates that a prox
tag is approaching.
- The LED bar flashes three times when a valid prox tag is being read by the keypad.
- If the prox tag is invalid, the LED bar stays on steadily and the keypad sounds an error tone.
- The brightness of the LED bar is adjustable from the [*][6] menu. When the backlight brightness is modified, the LED bar brightness is changed accordingly.
Downloading
The HS2LCDRF/HS2ICNRF products can be programmed over DLS V. This auto-detects
the keypad
type and downloads programming accordingly.
Wireless Device Setup and Programming (HS2ICNRF(P)x/HS2LCDRF(P)x)
This section describes how to enroll and program wireless devices such as
contacts, motion sensors and sirens on the alarm panel.
[804][000] Enroll Wireless Devices
- Once the HSM2HOST is installed and enrolled on the alarm panel wireless devices can be enrolled using the following method: Enter Installer Programming section [804][000]:
- When prompted, either activate the device (see device installation sheet) to enroll immediately or
enter a device ID number. Do the latter to pre-enroll devices then enroll them later at the customersite.
The alarm panel determines the type of device being enrolled and presents the appropriate programming options.
Table 5: Wireless Device OptionsDevice Type| Programming Options
---|---
Zone| (01) Zone type
(02) Partition assignment
(03) Zone label
Wireless key| (01) Partition assignment
(02) User label
Siren| (01) Partition assignment
(02) Siren label
Repeater| (01) Repeater label - Use the scroll keys or type in the corresponding number to select an option.
- Scroll through the available selections, key in a number or enter text as appropriate.
- Press [*] to accept and move to the next option.
- Once all options are configured, the system prompts to enroll the next device.
- Repeat the process described above until all wireless devices are enrolled.
NOTE: The configuration options listed above can be modified using [804][911] Modify Device.
[804][001]-[716] Wireless Device Configuration
To configure wireless devices:
- Enter Installer Programming section [804] then select one of the following sub-sections:
Table 6: Wireless Zone Sub-SectionsSub-Section| Description
---|---
001-128| Configure wireless zones
551-556| Configure wireless sirens
601-632| Configure wireless keys
701-716| Configure wireless keypads - Select a device to configure using the scroll keys or go directly to a specific device by entering a hotkey.
- Use the scroll buttons or enter a hot key to select a configuration option for the device. See device sheets for details.
- Press [*] to accept and move to the next option.
- Once all options are configured, the system returns to the base configuration menu.
Repeat the process described above to configure other wireless devices.
[804][801] RF Jam Detect
RF jam detection (continuous interfering transmissions on the radio network)
can be turned on or off.
When on, RF jamming is logged and reported.
To configure RF jamming:
- Enter Installer Programming section [804][801].
- Select one of the following options by scrolling or entering the hotkey:
Table 7: Jam Detect Options00| Enabled/Disabled| Jamming detection and reporting is enabled/disabled Note: Must be Enabled for UL/ULC listed installations.
---|---|---
01| UL 20/20-USA| Continuous RF jamming for 20 seconds
02| EN 30/60-Europe| 30 seconds of accumulated jamming within 60 seconds
03| Class 6 30/60-British| As EN (30/60) but reported only if the jamming duration exceeds 5 minutes - Press [*] to accept the selection.
- Press [#] to exit the section.
[804][802] Wireless Supervision Window
This option is used to program the length of time a wireless device can be
absent from the system before a fault is generated.
NOTE: For EN installations, 1 hour or 2 hours must be selected.
When option 06 is used, which configures the system to generate fault
conditions after a device has been detected as absent for 24 hours, smoke
detectors generate a fault condition after a maximum of 18 hours when the 200s
supervision toggle option is disabled.
To program the Wireless Supervisory Window:
- Enter Installer Programming section [804][802].
- Select one of the following options by scrolling or entering the hotkey
Table 8: Wireless Supervisory Window Options
00 | Enabled/Disabled |
---|---|
01 | After 1 Hour |
02 | After 2 Hour |
03 | After 4 Hour |
04 | After 8 Hour |
05 | After 12 Hour |
06 | After 24 Hour |
- Press [*] to accept the selection.
- Press [#] to exit the section.
NOTE: For UL Residential Burglary (UL1023), Home Health Care (UL1637), ULC Residential Burglary
(ULC/ORD-C1023) installations, the maximum Supervision window shall be set to 24 hours.
For UL Residential Fire (UL985) installations, the maximum supervision window is set to 200s.
For UL Commercial Burglary (UL1610/UL365) and ULC Residential Fire (ULC-S545), the maximum supervision window shall be set to 4 hours.
[804][810] Wireless Option
To program wireless options:
- Enter Installer Programming section [804][810].
- Select one of the following options by scrolling or entering the hotkey.
Table 9: Wireless Options01| RF Delin- quency| On: the system cannot be armed if a wireless supervisory trouble exists. An RF delinquency trouble is generated.
Off: wireless supervisory troubles do not prevent arming.
---|---|---
02
| Wireless Supervisory/ RF Jam
Alarm
| On: if a supervisory or jamming trouble occurs during Away arming, the siren activates and the event is logged and reported.
Off: supervisory or RF jam troubles during Away arming do not activate the siren or get logged and reported.
03| Module
Tamper
| On: module tampers are logged and reported.
Off: module tampers are not logged or reported.
04
| ****
Fire Super- vision
| On: fire devices are supervised every 200 seconds. If the device fails to report within this window, a supervision trouble is generated.
Off: fire devices follow the supervision window programmed in section 802, up to a maximum of 18 hours. The supervisory window can be programmed with a higher value, but detectors still go into fault after 18 hours.
- Press [*] to accept the selection and [#] to exit.
[804][841] Visual Verification Programming
To program wireless options:
- Enter Installer Programming section [804][841].
- Select one of the following options by scrolling or entering the hotkey
Table 10: Visual Verification Sub-Sections
[804][901]-[905] Delete Wireless Devices
To delete wireless devices:
- Enter Installer Programming section [804] then select one of the following sub-sections:
Table 11: Module Label Sub-Sections001| Visual Verification| On: Alarms trigger image capture from PIR Cameras
Off: Alarms do not trigger image capture from PIR Cameras
---|---|---
002| View Time Window| Alarm + 5 Minutes
Alarm + 15 minutes
Alarm + 1 Hour
003
|
View Other Alarms
| Fire key enabled/disabled
Duress key enabled/disabled
Medical key enabled/disabled
Panic key enabled/disabled
2. Select a device to delete using the scroll keys or go directly to a specific device by entering a hotkey.
3. Press [*] to delete or [#] to exit.
[804][921]-[925] Replace Wireless Devices
Use this option to replace a faulty device enrolled on the system with another
device of the same type
while maintaining the configuration of the original. The faulty device does
not need to be deleted. To replace a wireless device:
- Enter Installer Programming section [804] then select one of the following sub-sections.
Table 12: Replace Device Sub-SectionsSub-Section| Description
---|---
901| Delete wireless zone devices
902| Delete wireless key
903| Delete sirens
904| Delete repeaters
905| Delete keypads - Press [*] to select a sub-section. The first available device is displayed.
- Select a device to replace using the scroll keys or go to a specific device by entering a hotkey.
Press [*]. When prompted, activate the device (full enrollment) or enter the device ID (pre-enrollment).
A message is displayed confirming enrollment.
[804][990][001- 005] Show All Devices
Use this section to review wireless devices enrolled on the system and to view
serial numbers associated with each device.
To review wireless device information:
- Enter Installer Programming section [804][990] then select one of the following sub-sections:
Table 13: Wireless Device Sub-SectionsSub-Section| Description
---|---
921| Replace wireless zone devices
922| Replace wireless keys
923| Replace sirens
924| Replace repeater
925| Replace keypad
Sub-Section| Descriptions
---|---
001| All zones
002| Repeaters
003| Sirens
004| Wireless keys
005| Keypads - Press [*] to select a wireless device type. The first available device is displayed.
- Use the scroll keys to view the enrolled devices.
NOTE: This option is not fully supported by LED and ICON keypads.
[904] Placement Testing Wireless Devices (LCD keypads only)
This test is used to determine RF signal status for wireless devices and can
be performed at a system keypad or at the individual device. These
instructions pertain to testing at the keypad. For instructions on placement
testing at the device, refer to the installation sheet provided with the
wireless equipment.
The following test modes are available:001-128 – Test wireless zones.
Table 14: Wireless Device Placement Test Modes
001-128 | Test wireless zones | Test wireless devices individually by zone. |
---|---|---|
520 | Test all repeaters | Test each enrolled wireless repeater. |
521-528 for repeaters 1-8.
550| Test all sirens| Test each enrolled wireless siren.
551-556 for sirens 1-16
600| Test all wireless keys| Test individual wireless keys. Once in this section, press a button on the wireless key to begin the test.
601-632 for wireless keys 1-32.
700| Test all keypads| Test each enrolled keypad
701-716 for keypads 1-16.
Two test results are provided:
- 24-hour: Average results of signal strength testing over a 24-hour period.
- Now: Signal status results of the current test.
During testing, the Ready and Armed LED’s flash to indicate data is being
received. A flashing
Trouble LED indicates RF interference. The following status indicators may be
displayed:
Table 15: Wireless Device Status Indicators
LCD | Status | Repeater [905] |
---|---|---|
Strong | Strong signal strength | Repeater 1 |
Good | Good signal strength | Repeater 2 |
Poor | Poor signal strength | Repeater 3 |
1-Way | The device is operating in 1-way mode only. The alarm panel can- |
not configure or control the device
| Repeater 4
Not Test| Displayed as the Now result if no test was performed.| Repeater 5
None| Always displayed as the 24-hour result when testing wireless keys.|
Repeater 6
NOTE: For UL/ULC installations, only STRONG signal levels are acceptable.
Troubleshooting
- When attempting to assign a zone number to a wireless device, the keypad responds with a long beep.
- Ensure that the keypad is properly connected to the Corbus.
- After entering the ESN of a wireless device, then tripping it, the keypad does not indicate the zone is open.
- Ensure the ESN has been entered correctly.
- Ensure that the zone is enabled for the partition (if partition programming is used).
- Ensure that the wireless zone is not assigned to a zone used by HSM2108 modules, an on-board zone or a keypad zone.
- Ensure that the zone is programmed for something other than “Null Operation”. “Poor” or no results are received from a module placement test.
- Verify that you are testing the correct zone.
- Verify the device is in range of the keypad. Test the device in the same room as the receiver.
- Confirm that the keypad is properly connected to the Corbus.
- Check that the zone is being tested correctly. Refer to the instructions that came with the device.
- Check that the batteries are working and installed correctly.
- Look for large metal objects that may be preventing the signal from reaching the keypad.
- The device must be located where consistent “Good” results are obtained. If several devices show “Poor” results, or if panic pendants and wireless keys operate inconsistently, move the receiver.
For systems compliant with EN50131-1 and EN50131-3 the HS2LED keypad shall be used in conjunction with an LCD type keypad (HS2LCD(P) or HS2LCDRF(P)8 or HS2LCDWF(P)8) in order to be able to review logged events and also to allow overriding of conditions that inhibit setting of the alarm system. The HS2LED keypad alone cannot support these functions.
Word Library
Item #| Text| Item #| Text| Item #| Text| Item #| Text| Item #| Text| Item #|
Text| Item #| Text
---|---|---|---|---|---|---|---|---|---|---|---|---|---
001| Aborted| 037| Closed| 073| Feature| 109| Library| 145| Pool| 181| Tamper|
217| N
002| AC| 038| Closet| 074| Fence| 110| Light| 146| Porch| 182| Temperature|
218| O
003| Access| 039| Closing| 075| Fire| 111| Lights| 147| Power| 183| Test| 219|
P
004| Active| 040| Code| 076| First| 112| Living| 148| Press| 184| Time| 220| Q
005| Activity| 041| Communicator| 077| Floor| 113| Load| 149| Program| 185|
To| 221| R
006| Alarm| 042| Computer| 078| Force| 114| Loading| 150| Progress| 186|
Touchpad| 222| S
007| All| 043| Control| 079| Foyer| 115| Low| 151| Quiet| 187| Trouble| 223| T
008| AM| 044| Date| 080| Freeze| 116| Lower| 152| Rear| 188| Unbypass| 224| U
009| Area| 045| Daughter’s| 081| Front| 117| Main| 153| Receiver| 189| Unit|
225| V
010| Arm| 046| Degrees| 082| Furnace| 118| Master| 154| Report| 190| Up| 226|
W
011| Armed| 047| Delay| 083| Gallery| 119| Mat| 155| RF| 191| West| 227| X
012| Arming| 048| Den| 084| Garage| 120| Medical| 156| Right| 192| Window|
228| Y
013| Attic| 049| Desk| 085| Gas| 121| Memory| 157| Room| 193| Zone| 229| Z
014| Auxiliary| 050| Detector| 086| Glass| 122| Menu| 158| Safe| 194| 0| 230|
Space
015| Away| 051| Dining| 087| Goodbye| 123| Monoxide| 159| Saver| 195| 1| 231|
,
016| Baby| 052| Disarmed| 088| Gym| 124| Mother’s| 160| Schedule| 196| 2| 232|
–
017| Back| 053| Door| 089| Hallway| 125| Motion| 161| Screen| 197| 3| 233| _
(Underscore)
018| Bar| 054| Down| 090| Heat| 126| No| 162| Second| 198| 4| 234| *
019| Basement| 055| Download| 091| Hello| 127| North| 163| Sensor| 199| 5|
235| #
020| Bathroom| 056| Downstairs| 092| Help| 128| Not| 164| Service| 200| 6|
236| :
021| Battery| 057| Drawer| 093| High| 129| Now| 165| Shed| 201| 7| 237| /
022| Bedroom| 058| Driveway| 094| Home| 130| Number| 166| Shock| 202| 8| 238|
?
023| Bonus| 059| Duct| 095| House| 131| Off| 167| Shop| 203| 9| |
024| Bottom| 060| Duress| 096| In| 132| Office| 168| Side| 204| A| |
025| Breezeway| 061| East| 097| Install| 133| OK| 169| Siren| 205| B| |
026| Building| 062| Energy| 098| Interior| 134| On| 170| Sliding| 206| C| |
027| Bus| 063| Enter| 099| Intrusion| 135| Open| 171| Smoke| 207| D| |
028| Bypass| 064| Entry| 100| Invalid| 136| Opening| 172| Son’s| 208| E| |
029| Bypassed| 065| Error| 101| Is| 137| Panic| 173| Sound| 209| F| |
030| Cabinet| 066| Exercise| 102| Key| 138| Partition| 174| South| 210| G| |
031| Camera| 067| Exit| 103| Kids| 139| Patio| 175| Special| 211| H| |
032| Canceled| 068| Exterior| 104| Kitchen| 140| Pet| 176| Stairs| 212| I| |
033| Car| 069| Factory| 105| Latchkey| 141| Phone| 177| Stay| 213| J| |
034| Carbon| 070| Failure| 106| Laundry| 142| Please| 178| Sun| 214| K| |
035| Central| 071| Family| 107| Left| 143| PM| 179| Supervisory| 215| L| |
036| Chime| 072| Father’s| 108| Level| 144| Police| 180| System| 216| M| |
Limited Warranty
Digital Security Controls (DSC) warrants that for a period of 12 months from
the date of purchase, the product shall be free of defects in materials and
workmanship under normal use and that in fulfilment of any breach of such
warranty, DSC shall, at its option, repair or replace the defective equipment
upon return of the equipment to its repair depot. This warranty applies only
to defects in parts and workmanship and not to damage incurred in shipping or
handling, or damage due to causes beyond the control of Digital Security
Controls such as lightning, excessive voltage, mechanical shock, water damage,
or damage arising out of abuse, alteration or improper application of the
equipment. The foregoing warranty shall apply only to the original buyer, and
is and shall be in lieu of any and all other warranties, whether expressed or
implied and of all other obligations or liabilities on the part of Digital
Security Controls. Digital Security Controls neither assumes responsibility
for, nor authorizes any other person purporting to act on its behalf to modify
or to change this warranty, nor to assume for it any other warranty or
liability concerning this product. In no event shall Digital Security Controls
be liable for any direct, indirect or consequential damages, loss of
anticipated profits, loss of time or any other losses incurred by the buyer in
connection with the purchase, installation or operation or failure of this
product.
Warning: Digital Security Controls recommends that the entire system be
completely tested on a regular basis. However, despite frequent testing, and
due to, but not limited to, criminal tampering or electrical disruption, it is
possible for this product to fail to perform as expected. Important
Information: Changes/modifications not expressly approved by DSC could void
the user’s authority to operate this equipment.
IMPORTANT – READ CAREFULLY: DSC Software purchased with or without
Products and Components is copyrighted and is purchased under the following
license terms:
This End-User License Agreement (“EULA”) is a legal agreement between You (the
company, individual or entity who acquired the Software and any related
Hardware) and Digital Security Controls, a division of Tyco Safety Products
Canada Ltd. (“DSC”), the manufacturer of the integrated security systems and
the developer of the software and any related products or components
(“HARDWARE”) which You acquired.
If the DSC software product (“SOFTWARE PRODUCT” or “SOFTWARE”) is intended to
be accompanied by HARDWARE, and is NOT accompanied by new HARDWARE, You may
not use, copy or install the SOFTWARE PRODUCT. The SOFTWARE PRODUCT includes
computer software, and may include associated media, printed materials, and
“online” or electronic documentation.
Any software provided along with the Software Product that is associated with
a separate end-user license agreement is licensed to You under the terms of
that license agreement.
By installing, copying, downloading, storing, accessing or otherwise using the
Software Product, You agree unconditionally to be bound by the terms of this
EULA, even if this EULA is deemed to be a modification of any previous
arrangement or contract. If You do not agree to the terms of this EULA, DSC is
unwilling to license the Software Product to You, and You have no right to use
it. SOFTWARE PRODUCT LICENSE
The SOFTWARE PRODUCT is protected by copyright laws and international
copyright treaties, as well as other intellectual property laws and treaties.
The SOFTWARE PRODUCT is licensed, not sold.
-
GRANT OF LICENSE This EULA grants You the following rights:
- Software Installation and Use – For each license You acquire, You may have only one copy of the SOFTWARE PRODUCT installed.
- Storage/Network Use – The SOFTWARE PRODUCT may not be installed, accessed, displayed, run, shared or used concurrently on or from different computers, including a workstation, terminal or other digital electronic device (“Device”). In other words, if You have several workstations, You will have to acquire a license for each workstation where the SOFTWARE will be used.
- Backup Copy – You may make back-up copies of the SOFTWARE PRODUCT, but You may only have one copy per license installed at any given time. You may use the back-up copy solely for archival purposes. Except as expressly provided in this EULA, You may not otherwise make copies of the SOFTWARE PRODUCT, including the printed materials accompanying the SOFTWARE.
-
DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS
- Limitations on Reverse Engineering, Recompilations and Disassembly – You may not reverse engineer, decompile, or disassemble the SOFTWARE PRODUCT, except and only to the extent that such activity is expressly permitted by applicable law notwithstanding this limitation. You may not make any changes or modifications to the Software, without the written permission of an officer of DSC. You may not remove any proprietary notices, marks or labels from the Software Product. You shall institute reasonable measures to ensure compliance with the terms and conditions of this EULA.
- Separation of Component s – The Software Product is licensed as a single product. Its component parts may not be separated for use on more than one HARDWARE unit.
- Single INTEGRATED PRODUCT – If you acquired this SOFTWARE with HARDWARE, then the SOFTWARE PRODUCT is licensed with the HARDWARE as a single integrated product. In this case, the SOFTWARE PRODUCT may only be used with the HARDWARE as set forth in this EULA.
- Rental – You may not rent, lease or lend the SOFTWARE PRODUCT. You may not make it avail-able to others or post it on a server or web site.
- Software Product Transfer – You may transfer all of Your rights under this EULA only as part of a permanent sale or transfer of the HARDWARE, provided You retain no copies, You transfer all of the SOFTWARE PRODUCT (including all component parts, the media and printed materials, any upgrades and this EULA), and provided the recipient agrees to the terms of this EULA. If the SOFTWARE PRODUCT is an upgrade, any transfer must also include all prior versions of the SOFTWARE PRODUCT.
- Termination – Without prejudice to any other rights, DSC may terminate this EULA if You fail to comply with the terms and conditions of this EULA. In such event, You must destroy all copies of the SOFTWARE PRODUCT and all of its component parts.
- Trademarks – This EULA does not grant You any rights in connection with any trademarks or ser-vice marks of DSC or its suppliers.
-
COPYRIGHT – All title and intellectual property rights in and to the SOFTWARE PRODUCT
(including but not limited to any images, photographs, and text incorporated into the SOFTWARE PRODUCT), the accompanying printed materials, and any copies of the SOFTWARE PRODUCT, are owned by DSC or its suppliers. You may not copy the printed materials accompanying the SOFTWARE PRODUCT. All title and intellectual property rights in and to the content which may be accessed through use of the SOFTWARE PRODUCT are the property of the respective content owner and may be protected by applicable copyright or other intellectual property laws and treaties. This EULA grants You no rights to use such content. All rights not expressly granted under this EULA are reserved by DSC and its suppliers. -
EXPORT RESTRICTIONS – You agree that You will not export or re-export the SOFTWARE PRODUCT to any country, person, or entity subject to Canadian export restrictions.
-
CHOICE OF LAW – This Software License Agreement is governed by the laws of the Province of Ontario, Canada.
-
ARBITRATION – All disputes arising in connection with this Agreement shall be determined by final and binding arbitration in accordance with the Arbitration Act, and the parties agree to be bound by the arbitrator’s decision. The place of arbitration shall be Toronto, Canada, and the language of the arbitration shall be English.
-
LIMITED WARRANTY
- NO WARRANTY – DSC PROVIDES THE SOFTWARE “AS IS” WITHOUT WARRANTY. DSC DOES NOT WARRANT THAT THE SOFTWARE WILL MEET YOUR REQUIREMENTS OR THAT OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE.
- CHANGES IN OPERATING ENVIRONMENT – DSC shall not be responsible for problems caused by changes in the operating characteristics of the HARDWARE, or for problems in the interaction of the SOFTWARE PRODUCT with non-DSC-SOFTWARE or HARDWARE PRODUCTS.
- LIMITATION OF LIABILITY; WARRANTY REFLECTS ALLOCATION OF RISK – IN ANY EVENT, IF ANY STATUTE IMPLIES WARRANTIES OR CONDITIONS NOT STATED IN THIS LICENSE AGREEMENT, DSC’S ENTIRE LIABILITY UNDER ANY PROVISION OF THIS LICENSE AGREEMENT SHALL BE LIMITED TO THE GREATER OF THE AMOUNT ACTUALLY PAID BY YOU TO LICENSE THE SOFTWARE PRODUCT AND FIVE CANADIAN DOLLARS (CAD$5.00). BECAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
- DISCLAIMER OF WARRANTIES – THIS WARRANTY CONTAINS THE ENTIRE WARRANTY AND SHALL BE IN LIEU OF ANY AND ALL OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED (INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE) AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF DSC. DSC MAKES NO OTHER WARRANTIES. DSC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON PURPORTING TO ACT ON ITS BEHALF TO MODIFY OR TO CHANGE THIS WARRANTY, NOR TO ASSUME FOR IT ANY OTHER WARRANTY OR LIABILITY CONCERNING THIS SOFTWARE PRODUCT.
- EXCLUSIVE REMEDY AND LIMITATION OF WARRANTY – UNDER NO CIRCUMSTANCES SHALL DSC BE LIABLE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT DAMAGES BASED UPON BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, STRICT LIABILITY, OR ANY OTHER LEGAL THEORY. SUCH DAMAGES INCLUDE, BUT ARE NOT LIMITED TO, LOSS OF PROFITS, LOSS OF THE SOFTWARE PRODUCT OR ANY ASSOCIATED EQUIPMENT, COST OF CAPITAL, COST OF SUBSTITUTE OR REPLACEMENT EQUIPMENT, FACILITIES OR SERVICES, DOWN TIME, PURCHASERS TIME, THE CLAIMS OF THIRD PARTIES, INCLUDING CUSTOMERS, AND INJURY TO PROPERTY.
WARNING: DSC recommends that the entire system be completely tested on a regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical disruption, it is possible for this SOFTWARE PRODUCT to fail to perform as expected.
Operating Instructions shall be made available to the user.
The trademarks, logos, and service marks displayed on this document are
registered in the United States [or other countries]. Any misuse of the
trademarks is strictly prohibited and Tyco International Ltd. will
aggressively enforce its intellectual property rights to the fullest extent of
the law, including pursuit of criminal prosecution wherever necessary. All
trademarks not owned by Tyco International Ltd. are the property of their
respective owners, and are used with permission or allowed under applicable
laws. Product offerings and specifications are subject to change without
notice. Actual products may vary from photos. Not all products include all
features. Availability varies by region; contact your sales representative.
This product contains open source components QT Version 4.7.3 and Linux Kernel
License: Version 2.6. Both of these components are protected by copyright and
have terms and conditions associated with their use. The open source software
code and associated components used in this product are down-loadable from the
DSC website. Please visit
http://www.dsc.com/open-source-documentation for detailed information.
FCC Compliance Statement
CAUTION: Changes or modifications not expressly approved by DSC could
void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed
and used properly, in strict accordance with the manufacturer’s instructions,
may cause interference to radio and television reception. It has been type
tested and found to comply with the limits for Class B device in accordance
with the specifications in Subpart “B” of Part 15 of FCC Rules, which are
designed to provide reasonable protection against such interference in any
residential installation. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
interference to television or radio reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Re-orient the receiving antenna
- Relocate the alarm control with respect to the receiver
- Move the alarm control away from the receiver
- Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the FCC helpful: “How to Identify and Resolve Radio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office, Washington, D.C. 20402, Stock # 004-000-00345-4.
Industry Canada Compliance Statement
CAN ICES-3(b)/NMB-3(b)
For Commercial Fire Monitoring applications the HS2TCHP keypad is for
supplementary use only.
©2015 Tyco Security Products. All Rights Reserved •
www.dsc.com • Tech Support:
1-800-387-3630 (Canada, US),
905-760-3000