Order Code| Input Voltage| Power Consumption| Light Color| Life Span| Luminous
Flux| Dimensions
---|---|---|---|---|---|---
ZM5121|
220–240 V AC, 50/60 Hz
|
6 W
| Warm white|
30 000 h
|
450 lm
|
Ø 120 × 40 mm
ZM5122| Neutral white
ZM5131|
220–240 V AC, 50/60 Hz
|
12.5 W
| Warm white|
30 000 h
|
1 000 lm
|
Ø 170 × 40 mm
ZM5132| Neutral white
ZM5141|
220–240 V AC, 50/60 Hz
|
18 W
| Warm white|
30 000 h
|
1 500 lm
|
Ø 224 × 40 mm
ZM5142| Neutral white
ZM5151|
220–240 V AC, 50/60 Hz
|
24 W
| Warm white|
30 000 h
|
2 000 lm
|
Ø 300 × 40 mm
ZM5152| Neutral white
Order Code| Input Voltage| Power Consumption| Light Color| Life Span| Luminous
Flux| Dimensions
---|---|---|---|---|---|---
ZM6121|
220–240 V AC, 50/60 Hz
|
6 W
| Warm white|
30 000 h
|
450 lm
|
120 × 120 × 40 mm
ZM6122| Neutral white
ZM6131|
220–240 V AC, 50/60 Hz
|
12.5 W
| Warm white|
30 000 h
|
1 000 lm
|
170 × 170 × 40 mm
ZM6132| Neutral white
ZM6141|
220–240 V AC, 50/60 Hz
|
18 W
| Warm white|
30 000 h
|
1 500 lm
|
225 × 225 × 40 mm
ZM6142| Neutral white
ZM6151|
220–240 V AC, 50/60 Hz
|
24 W
| Warm white|
30 000 h
|
2 000 lm
|
300 × 300 × 40 mm
ZM6152| Neutral white
GB | LED panel, surface-mounted
LED luminaire is designed for indoor use to be mounted on a solid base.Ingress Protection: IP20 – for indoor use
Mounting
To ensure protection against injury by electric current, it is necessary to remove the connected testing conductors at the power supply input during installation and replace them with conductors with double or reinforced insulation. Mount the lamp firmly onto a solid basis, for example a wall, a ceiling and like that.Connect the power cord to the mains 230 V. Connecting conductor must not be connected to the mains at time of installation. This operation can be carried out only by an authorized person.
WARNING
- Luminaire is suitable entirely for fixed mounting.
- The luminaire can be connected only to the electric distribution network, whose installation and protection complies with the applicable standards.
- Before any manipulation or servicing of the luminaire disconnect the luminaire from AC power. This operation can be carried out only by an authorized person.
- In case of any damage to any part of the luminaire, don’t use it.
- LED chips inside the luminaire are not replaceable.
- Don’t change inner wiring of the luminaire.
- In case of broken cover don’t use the luminaire and replace broken cover with new one immediately.
EMOS spol. s r.o. declares that the LED panel, surface-mounted is in compliance with the essential requirements and other relevant provisions of Directive. The device can be freely operated in the EU. The Declaration of Conformity can be found at http://www.emos.eu/download.