marco 1000940 POUR’D Control Box Instruction Manual

June 6, 2024
marco

marco 1000940 POUR’D Control Box

marco 1000940 POUR’D Control Box
PRO

Connections

marco 1000940 POUR’D Control Box 2

This equipment must be installed with adequate backflow protection to comply with all applicable federal, state and local codes.

Place on top of MIX boiler or on shelf make sure rubber feet are only points of contact

VITOP BIB connector

marco 1000940 POUR’D Control Box
3

Remove red plastic seal from tap

HOT/COLD WATER, DILUTED CONCENTRATE & CONCENTRATE SHOT
3 button connections (1000942 3b concentrate)marco 1000940 POUR’D Control
Box 4 marco 1000940 POUR’D Control Box 5

Control box setup

marco 1000940 POUR’D Control Box
6

Boiler setupmarco 1000940 POUR’D Control Box 7

volumes or ratios

Control box setupmarco 1000940 POUR’D Control Box 10

Connecting Hoses

Single Source Ready to Drink (3B font, 3 volumes3marco 1000940 POUR’D
Control Box 11

Concentrate Shot

marco 1000940 POUR’D Control Box
12

Multiple Source Ready to Drinkmarco 1000940 POUR’D Control Box
13 marco 1000940 POUR’D Control Box
14

Engineering Setup & Calibrationmarco 1000940 POUR’D Control Box
15marco 1000940 POUR’D Control Box 16

3 finger press long hold Set mode UC MIX BOTH Set all temperatures the samemarco 1000940 POUR’D Control Box 17

Button Setup

Programmable buttons
Program and change buttons accordinglymarco 1000940 POUR’D Control Box
18 marco 1000940 POUR’D Control Box
19

Cleaning

  1. Disconnect Beverage source from silicone tubing.
  2. Put tubing into a bucket of cleaning solution.
  3. Press cleaning option on control box.marco 1000940 POUR’D Control Box 20
  4.  Replace cleaning solution with clean hot water.
  5. Press cleaning option on control box.marco 1000940 POUR’D Control Box 21
  6.  Reconnect BIB to silicone tubing.
  7. Press any button on font 5 times to fully clear tubing/pump of any residual water. Cleaning takes approximately 60 seconds.
  8. Font is now ready to operate.

marco 1000940 POUR’D Control Box 22

Operating Font

marco 1000940 POUR’D Control Box 23

  1. Push & Hold
  2. Push & Release

RISK OF SCALDING

  1. If using a boiler, turn off before cleaning to prevent accidental triggering of a dispense.
  2. Beware of accidentally operating the control box especially when cleaning around the push buttons.
  3. Do not use abrasive cloths or creams, as this will spoil the finish of the control box.

Marco Beverage Systems Limited. 63d Heather Road, Sandyford Industrial Estate, Dublin 18 t: +353 (0)1 295 2674 f: +353 (0)1 295 3715 e: sales@marco.ie www.marcobeveragesystems.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals