A Midi sized IP camera with a powerful IR array instead of multiple IRs to help minimise reflection from insects or spider’s webs. Perfect for capturing top quality, true day to night images.

INSTRUCTIONS

IPCZIP815 5MP IP Midi Sized Fixed Eyeball
1 IPCZIP815 5MP IP Midi Sized Fixed Eyeball
2

The camera is provided with a fly lead with a 2.1mm DC socket and standard RJ45 Ethernet socket.

Option 1 – Power the camera from12V DC (via the 2.1mm DC Socket), the current consumption is 750mA.

The camera is polarity sensitive so connections must be correctly made.

Option 2 – Power the camera using a PoE 48V RJ45 Socket

  • When connecting ZIP PoE NVR plug the camera directly into the NVRs built in PoE switch.
  • The camera should automatically become visible after being connected for approximately 1 minute.
  1. If using a separate PoE switch or an IPmitter (wireless bridge), the camera needs to be manually configured, please find the below guide.
    www.zipdvr.com/howto/TIP459-How-To-Add-IP- Cameras.html

  2. To search for ZIP IP cameras on a network via a Windows PC then use the ZIP Finder tool.
    www.softcctv.com/store/Item/ Zip-Finder-IP-CCTV-Security-Camera-Discovery- Tool

  3. Default IP – 192.168.10.1

  4. User Name: admin

  5. Password: 777777

Mounting

IPCZIP815 5MP IP Midi Sized Fixed Eyeball
3

  1. Twist the collar covering the fixing plate to unlock it then lift off
  2. Remove the small screw holding the locking plate in place and then slide out the locking plate.
  3. Screw through the three holes in the base and into the mounting surface using the screws and wall plugs provided.IPCZIP815 5MP IP Midi Sized Fixed Eyeball 4

All specifications are approximate. System Q Ltd reserves the right to change product specifications or features without notice. Whilst every effort is made to ensure that these instructions are complete and accurate, System Q Ltd cannot be held responsible for any losses, no matter how they arise, from errors or omissions in these instructions, or the performance or non- performance of the equipment refered to.

This symbol indicates that equipment must not be mixed with general household waste. For treatment, recovery and recycling please return to your local designated WEE/CG0783SS collection point as defined by your local council.

Scan QR Code for Full Manual
https://www.systemq.com /PDF/manual/xIPCZIP815.pdf

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Zip User Manuals

Related Manuals