Trisa 9496.21 Upright Vacuum Cleaner Instruction Manual
- June 3, 2024
- Trisa
Table of Contents
- Trisa 9496.21 Upright Vacuum Cleaner
- Safety instructions
- Disposal
- Technical data
- Assembling
- Charge battery
- Appliance description
- Use
- Cleaning
- Problem / Cause
- Replacement accessories
- Warranty information
- Service & Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Trisa 9496.21 Upright Vacuum Cleaner
Safety instructions
- Please read all safety instructions and observe, properly store and pass on to subsequent owners this operation manual.
- Mains connection: The voltage must comply with that shown on the appliance label.
- Regularly check if the power cable/appliance/extension lead is defective. Never switch on damaged appliances (incl. mains lead) have repairs carried out/obtain a replacement from the manufacturer, the manufacturer’s service point or from qualified experts.
- Don’t pull the flex over sharp edges. Don’t wedge it. Don’t bend it. A short circuit can occur if the cable breaks. Never pull on the mains cable/with damp hands.
- Always switch off the device and plug out the power cable whenever you leave it unattended, before assembling/ disassembling, cleaning, when it fails to work properly, after use. Switch the appliance off and pull the plug out of the mains when it is not in use.
- Never immerse appliance in water/other fluids. The danger of short-circuiting!
- Children aged 8 years or Over and persons with reduced physical, sensory or mental capabilities, lack of experience or knowledge may only Use the appliance if they are supervised by a person who is responsible for their safety or if they have been shown how to use the appliance safely and they have understood the risks inherent in its use.
- Cleaning and maintenance tasks may not be carried out by children without supervision.
- Children should not be allowed to play with the appliance. Keep the appliance and its power cable out of reach of children aged under 8. Never leave the appliance unattended while in operation.
- Keep packaging (e.g. plastic bags) away from children.
- Never place the appliance/cable on hot surfaces or near open flames. Do not store/expose the appliance to intense heat (from radiators, or prolonged sunshine). Only extinguish burning appliances using a fire blanket.
- Do not use attachments not recommended/sold by the manufacturer
- The appliance is designed for household use and not for industrial operation. Do not operate the appliance outdoors.
- Do not use this appliance near the water (bathtubs, washbasins, etc.) nor expose it to rain or other humidity. Ensure hands are dry when using the appliance!
- If the device falls into water, have it checked out by an electrician before using it again.
- Never open the appliance yourself – the risk of injury! Only trained experts should repair electrical appliances. Unskilled repairs can cause considerable danger to the user.
- No warranty for any damage can be accepted if the appliance is used for improper purpose,
- Wrongly operated or unprofessionally repaired. In such a case, any warranty Claim is void.
- Never place fingers or objects into appliance openings. Do not cover appliance opening.
- Remove any items (hair, flutf etc.) that might block the brushes and wheels.
- Never vacuum damp/wet floors/carpets; solvents; corrosive substances; burning, hot, sharp-edged, explosive or flammable substances.
- Only open the appliance at the positions intended for this purpose (changing the filter etc).
- Never use the vacuum cleaner unless there is a filter in place. The appliance must not be directed onto people or animals.
- Nozzles and tubes must not be allowed near to anybody’s head. Danger to eyes and ears.
- To avoid risk of injury, keep your hair, hands and feet away from the rotating brush. Operate appliance only in an ambient temperature of 5°45°C.
- If the appliance is not used for long periods, remove the rechargeable battery.
- lf rechargeable battery is used incorrectly, liquid can leak out -avoid physical contact with this liquid. If liquid comes in contact with the eyes, a doctor must be consulted.
- Do not store unused rechargeable battery in the vicinity of coins, keys, nails, screws or other metal objects.
Disposal
- Make worn-out appliances unusable. Pull out the mains plug and sever the cord. Electric appliances are to be returned to a shop of sale or handed over to an official dump. No household waste. Must be disposed of in accordance with local regulations.
CE
- In accordance with the European guidelines for safety and EMC.
- We reserve the right to make changes in design, equipment, and technical data as well as errors.
Welcome
Please read all the information provided in these instructions. Keep the instructions in a safe place and pass them on to further users. The appliance must only be used for the intended purpose according to these instructions. Observe the notes on safety regulations. The appliance is best operated using an RCD (max. 30 mA).
Technical data
300 ml
- Dust container
1,8 m
- Cable length
32 V
- Volts
1,19 m
- Size
84 dB
- Noise level
3000 mAh
- Battery capacity
ECO: Ca.45 min. / 80 min.
MID: ca.22 min./27 min.
MAX: ca.11 min. / *13 min.
- Battery charge
ca. 3,4 kg
- Weight
5
- Charging time [hours]
- Manual vacuum cleaner
Assembling
- Mark, drill
- Insert rawlplugs, screw in screws
- Attach the vacuum cleaner
Warning: Check wall material.
Charge battery
- Insert rechargeable battery
- Plug-in cable
- Plugin
- Charging
WARNING
- The first three times, use until a standstill is reached and then charge for 12 hours.
- Optionally the battery can be connected directly to the charging cable.
Appliance description
Nozzle attachments
Use
Preparation
- Insert rechargeable battery
- Attach the tube with the floor cleaning head
- Attach appropriate nozzle
Vacuum-clean
- Switch on
- If required: change level
Never vacuum without filters/roller brushes inserted!
After use
- Switch off
- Remove nozzle
Cleaning
WARNING
- Remove the battery first
- Assembly in reverse
Can be wiped with a damp cloth, then dried. Do not use scourers or solvents.
Empty dust container
Shake out the motor filter
- Replace if required. Must not get wet!
Shake out HEPA filter
- Replace if required. Must not get wet!
Cleaning roller brush
Problem / Cause
- Appliance not working
- Is the battery empty? Did the battery insert correctly?
- No suction power
- HEPA filter/roller brush/tube clogged?
- Dust container full?
- After brief use, the battery is already empty again
- Battery fully charged?
- Battery too old? – contact specialist.
Replacement accessories
Art. 9496 98 00
- Motor filter
Art. 9496 98 01
- Battery
Art. 9496 98 12
- HEPA filter white
Art. 9496 98 11
- Replacement roll
Art. 9496 98 17
- HEPA filter grey
Art. 9496 98 03
- Wall bracket
Warranty information
With this appliance you get a 5 year guarantee starting from the date of purchase (the battery comes with a 1-year or 500 charging cycles warranty). Under the guarantee, in the case of material or manufacturing defects, the appliance will be replaced or repaired. Replacement with a new appliance or a money-back return is not possible. Excluded from the guarantee is normal wear and tare, commercial use, alterations to the appliance as purchased, cleaning activities, consequences of improper use or damage by the purchaser or a third person, damage, that can be attributed to external circumstances or caused by the batteries. The guarantee requires that the faulty appliance be returned at the purchaser’s expense along with the retail outlet dated and signed guarantee card or a sales receipt.
Service & Support
Trisa Electronics AG
- Kantonsstrasse 121 CH-6234 Triengen
- info@trisaelectronics.ch
- Tel: +41 41 933 00 30