Honeywell EDA51K-0 ScanPal EDA51K Mobile Computer User Guide
- June 5, 2024
- Honeywell
Table of Contents
- Honeywell EDA51K-0 ScanPal EDA51K Mobile Computer
- Remove the packing
- Mounting Main Battery
- Charging/Synchronization
- Suspend/reactivate terminal
- Installing memory card
- Installing SIM card (only EDA51K-1)
- Using scanning engine
- Aiming beam
- Technical Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Honeywell EDA51K-0 ScanPal EDA51K Mobile Computer
Remove the packing
Please check to see if it contains the following items:
- ScanPal EDA51K Mobile Computer;
- Main battery (3.8V, lithium-ion battery);
- 10W battery adapter;
- Interchangeable adapter plug;
- USB power cable;
- Basic Guide
Front panel
Rear panel
Left side Right side
Base
Mounting Main Battery
The use of the wrong model of the battery will pose a threat of explosion.
Please dispose of the
used battery according to instructions and local regulations. As far as
possible dispose of the battery as a product for recycling; do not dispose of
it as normal thrash.
Please ensure that all the component parts are dry before connecting the
terminal/battery to external equipment. Damage to the equipment due to
connection using wet parts is not covered by warranty.
EDA51K is equipped with a battery that comes in separate packing. Please
install the battery in accordance with the following steps.
- Press the battery cover’s safety button and move it to the right unlocking position;
- Remove the battery cover using its locking latch;
- Insert the battery (first insert the battery at the battery connector end before pressing the rest of the battery to ensure that the battery is connected to the mobile phone);
- Press the battery cover (first insert the part of the battery cover away from the battery connector before inserting the rest of the battery cover);
- Move the battery safety to the left side locking position.
Press the battery cover before sliding the battery locking button to the right to unlock it
Press the battery cover before sliding the battery cover locking button towards the left to lock it
Charging/Synchronization
Synchronizing communication
1. Unlock the USB cover at the base of ScanPal EDA51K;
2. Connect ScanPal EDA51K with the computer using the USB charging cable
Charging
- Unlock the USB cover at the base of ScanPal EDA51K;
- Use a USB charging cable to connect ScanPal EDA51K with a power adapter;
- Ensure that the interchangeable adapter is plugged into the power
- Connect the power adapter to the wall socket and begin charging the ScanPaul EDA51K battery
Before using the ScanPaul EDA51K terminal, charge it for at least 4 hours in
accordance with its battery model using the ScanPaul EDA51K charger
. Note:
Use of Honeywell’s external device, battery, USB charging cable, and power
adapter is recommended. Any damage caused to this product as a result of use
of the above accessories that are not from Honeywell will not be covered by
our warranty.
Suspend/reactivate terminal
- Press the power key then release (press for less than 2 seconds);
- To reactivate the device from suspend mode, press the power key then release (press for less than 2 seconds).
Restarting device
If there is a problem with the system, Press the power key for about 13
seconds before releasing to restart ScanPal EDA51K. ScanPal EDA51K power
indication
The following sets out the status of ScanPal EDA51K as indicated by its power
indicator light
Non-charging Status
Off| Battery is normal
Flickering orange light| Low battery charge
Charging Status
Constant green light| Fully-charged
Flickering green light| Charging, battery almost fully-charged
Orange light| Charging, low battery
Flickering red light| Battery is abnormal
Installing memory card
- Switch off the device;
- Press the battery cover’s safety key, before sliding the battery locking button to the right to unlock it;
- Remove the battery cover using its locking latch;
- Remove the battery (remove it from its bottom part before pulling out the entire battery);
- Lift the Micro TF card’s silica gel cover;
- Lift the Micro TF card cover and insert the card;
- Insert the battery (first insert the side with connector before pressing the
- Press the battery cover to lock it;
- Press the battery cover before sliding the battery cover locking button towards the left to lock it;
- Switch on the device.
Installing SIM card (only EDA51K-1)
- Press the battery cover’s safety key, before sliding the battery locking button to the right to unlock it;
- Remove the battery cover using its locking latch;
- Remove the battery (remove it from its bottom part before pulling out the entire battery);
- Lift the Micro SIM card’s silica gel cover;
- Lift the Micro SIM card cover and insert the card;
- Insert the battery (first insert the side with connector before pressing the
- Press the battery cover’s safety key, before sliding the battery locking button to the right to unlock it;
- Remove the battery cover using its locking latch
- Remove the battery (remove it from its bottom part before pulling out the entire battery);
- Lift the Micro SIM card’s silica gel cover;
- Lift the Micro SIM card cover and insert the card;
- Insert the battery (first insert the side with connector before pressing the
Using scanning engine
Aim the beam at the bar code and adjust the angle between it and the bar code to obtain the best effect. The recommended distance between the device and the bar code is 4-10 inches (10-25 cm).
- Click demo application on the interface and select the demo program;
- Click ‘scan’ on the screen, or press the scanner key;
- Aim ScanPaul EDA51K terminal at the bar code;
- Adjust the aiming beam. To obtain the best performance one should avoid very small angles. By way of scanning the bar code’s reflect, slowly move the aiming beam along with the bar code;
- The terminal will emit a buzzer when decoding of the bar code is successful; this means information on the bar code has been captured by the terminal.
Aiming beam
The aiming beam becomes narrow when the terminal is close to the bar code;
conversely, it becomes wider. When the bar code’s measurement is smaller, the
aiming beam must be closer to the bar code
Conversely, the aiming beam must be further away from the bar code
.
Technical Support
For information on technical support, product after-sales service, and repairs
please visit: www.honeywellaidc.com
User fileFor the version of this document in the local language please visit:
www.honeywellaidc.com.
Patents
For information on patents please refer to:
www.honeywellaidc.com/patents.
Duration of warranty repair Please visit:
www.honeywellaidc.com/warranty_information
To obtain information on warranty repair for your product.
Disclaimer
Honeywell International Inc. (HII) reserves the right to change the
specifications and other information without notice. Under any circumstances,
the reader should check whether any such changes have been made. The
information contained herein does not tantamount to any warranties/undertaking
made by HII. HII shall not bear any direct or indirect losses for any
technical or editorial error and omission.
The text in this file contains proprietary information protected by copyright.
Photocopying or duplication of any contents herein or translation of such
contents into other languages is prohibited without HII’s prior written
consent.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference and
- this device must accept any interference received, including interference that may cause undesired operation of the device This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in particular installation
equipment and on. the user is encouraged to try to correct the interference by one or more of the following measures:
-
Reorient or relocate the receiving antenna.
-
Increase the separation between the equipment and receiver.
-
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected. -
Consult the dealer or an experienced radio/TV technician for help.
You are cautioned that changes or modifications note)(press approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC RF Radiation E)
-
This Transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter -
For body-worn operation. this device has been tested and meets FCC RF e)(posture guidelines. When used with an accessory that contains metal may not ensure compliance with FCC RF e)(posture guide
lines.
This C lass B digita l appara tus comp lies with Ca nadian JC ES-003
Cet appareil numerique de classe Best conforme a la norme NMB-003.
Canadian Notice
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to
The following two conditions:
- this device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device
Operation in the band 5150-5250 MHz is only for indoor use to reduce the
potential for harmful int reference to co-channel mobile satellite systems. La
bande S 150 -5 250 MHz est r e serv e s uniquement pour une utilisation a
l’int e rieur afin de reduire les risques de brouillage pr e judiciable au)(
syst e mes de satellites mobiles utilisant les m €!me s canau)
For the frequency 5600-5650 MHz, no operation is permitted
Pour la fr e quence 5600 -5650 MH z. aucune op e ration est autoris e e.
RF Radiation Exposure Statement:
For body-worn operation, this phone has been tested and meets RF exposure
guidelines when used with an accessory that contains no metal. The use of
other accessories may not ensure compliance with RF
Exposure of humans to RF fields (RSS-102)
The computers employ low gain integral antennas that do not emit RF field in
excess of Health Canada limits for the general population: consult Safety Code
6, obtainable from Health Canada’s Web site a.
h ttp:ff www.hc sc.gc.ca
The radiated energy from the antennas connected to the wireless adapters
conforms to the IC limit of the RF exposure requirement regarding IC RSS-102,
Issue 5 clause 4
References
- Industrial Automation | Honeywell
- Safety and Productivity Solutions | Honeywell
- Safety and Productivity Solutions | Honeywell
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>