USER MANUAL HF05
Industrial heat flux sensor
Warning statements
Follow the installation instructions of this user manual.
The sensor and sensor-to-cable transition should not be exposed to
significant force.
Putting more than 12 Volt across the sensor wiring can lead to permanent
damage to the sensor.
Do not use “open circuit detection” when measuring the sensor output.
**** Only for supply with the optional CE type examination (ATEX)
certificate: ask the supplier for ATEX rated operating conditions.
List of symbols
Quantities | Symbol | Unit |
---|---|---|
Heat flux | Φ | W/m² |
Voltage output | U | V |
Sensitivity | S | V/(W/m²) |
Temperature | T | °C |
Temperature difference | ΔT | °C, K |
Resistance | R | Ω |
Subscripts | ||
--- | --- | |
property of thermopile sensor | sensor | |
calibration reference condition | reference | |
property of the object on which HF05 is mounted | object | |
property at the (object) surface | surface | |
property of the surrounding environment | environment |
Introduction
HF05 measures heat flux and surface temperature in industrial environments.
The sensor has a fully sealed stainless steel body and a PTFE cable. It is
robust, stable, and can withstand relatively extreme environmental conditions.
It is suitable for long-term use at one location as well as repeated
installation when a measuring system is used at multiple
locations.
HF05 measures heat flux through the object on which it is mounted, in W/m², as
well as it is surface temperature in °C. The sensors in HF05 are a thermopile
and a type K thermocouple. The thermopile measures the temperature difference
across the body of HF05, creating an output that is representative of the
local heat flux. The thermocouple
measures the absolute temperature of the surface on which HF05 is mounted. A
thermopile and a thermocouple are passive sensors; they do not require power.
Using HF05 is easy. It can be connected directly to commonly used data logging systems. The heat flux, Φ, in W/m², is calculated by dividing the HF05 output, a small voltage U, by the sensitivity S.
The measurement function of HF05 is:
Φ = U/S (Formula 0.1)
The sensitivity is provided with HF05 on its product certificate.
HF05 complies with the requirements of ASTM C1041-85 (2007) Standard Practice
for InSitu Measurements of Heat Flux in Industrial Thermal Insulation Using
Heat Flux Transducers.
Equipped with heavy-duty cabling, and having a fully stainless steel casing so
that moisture does not penetrate the sensor, HF05 has proven to be very
reliable. It survives long-term outdoor installation.
HF05 is most suitable for relative measurements, i.e. monitoring of trends
relative to a certain reference point in time or comparing heat flux at one
location to the heat flux at another location. Typical applications of HF05
are studies of fouling in industrial environments mounted on tubing or on the
jacket of reactors. HF05 is also used for the performance evaluation of
industrial insulation.
If the user wants to perform accurate absolute measurements with HF05, as
opposed to relative measurements, the user must make his own uncertainty
evaluation and correction for systematic errors. See the appendix on
uncertainty evaluation. However, in many situations the analysis of trends is
sufficient. In that case, high absolute measurement accuracy is not needed,
and a formal uncertainty evaluation is not necessary.
HF05 calibration is traceable to international standards. The factory calibration method follows the recommended practice of ASTM C1130. The recommended calibration interval of heat flux sensors is 2 years.
Suggested use of HF05:
- industrial heat flux measurements
- performance evaluation of industrial insulation
See also:
- models IHF01 and IHF02 for higher temperatures up to 900 °C
- model HFP01 for lower temperatures up to 70 °C
- our complete product range of heat flux sensors
- our range of industrial heat flux sensors (PDF)
Figure 0.1 HF05 industrial heat flux sensor
Ordering and checking at delivery
1.1 Ordering HF05
The standard configuration of HF05 is with 3 meters cable.
Common options are:
- longer cable (specify total cable length in m)
- connector at the HF05 cable end
- EC type-examination certificate (ATEX) II 2G Ex db IIC T6
- extension cable with 2 connectors matching cable connector and chassis connector (specify cable length in m)
- chassis connector with internal wiring (colour code of wiring identical to cable color code)
1.2 Included items
Arriving at the customer, the delivery should include:
- heat flux sensor HF05
- cable of the length as ordered
- product certificate matching the instrument serial number
1.3 Quick instrument check
A quick test of the instrument can be done by connecting it to a multimeter. 1
Check the electrical resistance of the heat flux sensor between the black [-]
and red [+] wires and the thermocouple between the green [+] and white [-]
wires. Use a multimeter at the 100 Ω range. Measure the sensor resistance
first with one polarity, then reverse the polarity. Take the average value.
Typical resistance should be the nominal sensor resistance of 3 Ω for the
thermopile sensor plus 0.2 Ω/m (resistance per meter cable ) for the total
resistance of two wires (back and forth added). For the thermocouple work with
3 Ω/m resistance per meter cable. Infinite resistance indicates a broken
circuit; zero or a lower than 1 Ω resistance indicates a short circuit. 2.
Check if the heat flux sensor reacts to heat: put the multimeter at its most
sensitive range of DC voltage measurement, typically the 100 x 10 -³ VDC range
or lower. Expose the sensor heat, for instance touching it with your hand. The
signal should read > 2 x 10 -³ V now. Exposing the side flush with flanges
should generate a positive signal, doing the same at the opposite side, the
sign of the output voltage reverses. Also look at the reaction of the
thermocouple to heat. The thermocouple is located at the side flush with the
flanges. 3. Inspect the instrument for any damage. 4. Check the sensor serial
number engraved on the sensor side against the certificate provided with the
sensor.
Instrument principle and theory
HF05’s scientific name is heat flux sensor. A heat flux sensor measures the
heat flux density through the sensor itself. This quantity, expressed in W/m
², is usually called “heat flux”. HF05 users typically assume that the
measured heat flux is representative of the undisturbed heat flux at the
location of the sensor. Users may also apply corrections based on scientific
judgement.
The heat flux sensor in HF05 is a thermopile. This thermopile measures the
temperature difference across the body of HF05. Working completely passive,
the thermopile generates a small voltage that is a linear function of this
temperature difference. The heat flux is proportional to the same temperature
difference divided by the effective thermal conductivity of the heat flux
sensor body. Using HF05 is easy. For readout the user only needs an accurate
voltmeter that works in the millivolt range. To convert the measured voltage,
U, to a heat flux Φ, the voltage must be divided by the sensitivity S, a
constant that is supplied with each individual sensor. The temperature sensor
inside HF05 is a type K thermocouple located at the side of the sensor flush
with the flanges.
Figure 2.1 The general working principle of a heat flux sensor. The
sensor inside HF05 is a thermopile. A thermopile consists of a number of
thermocouples, each consisting of two metal alloys marked 1 and 2,
electrically connected in series. A single thermocouple will generate an
output voltage that is proportional to the temperature difference between its
hot- and cold joints. Putting thermocouples in series amplifies the signal. In
a heat flux sensor, the hot- and cold joints are located at the opposite
sensor surfaces 4 and 5. In steady state, the heat flux 6 is a linear function
of the temperature difference across the sensor and the average thermal
conductivity of the sensor body, 3. The thermopile generates a voltage output
proportional to the heat flux through the sensor. The exact sensitivity of the
sensor is determined by the manufacturer by calibration, and
is found on the calibration certificate that is supplied with each sensor.
Heat flux sensors such as HF05, for use in industry, are typically calibrated under the following reference conditions:
- conductive heat flux (as opposed to radiative or convective heat flux)
- homogeneous heat flux across the sensor and guard surface
- room temperature
- heat flux in the order of 350 W/m²
Unique features of HF05 are:
- low electrical resistance (low pickup of electrical noise)
- high sensitivity (good signal to noise ratio in the low-flux environments such as buildings)
- robustness, including a strong cable
- built-in temperature sensor; type K thermocouple
- IP protection class: IP67 (essential for outdoor application)
Measuring with heat flux sensors, errors may be caused by differences between calibration reference conditions and the conditions during use. The user should analyze his own experiment and make his own uncertainty evaluation.
Figure 2.2 HF05: the heat flux sensor (2) is connected to a short rigid stainless steel tube. This sensor-to-cable transition is connected to a PTFE cable (3). Two mounting flanges (1) are attached to the sensor body.
Specifications of HF05
3.1 Specifications of HF05
HF05 measures the heat flux density through the surface of the sensor. This
quantity, expressed in W/m², is called heat flux. It also measures the
absolute temperature of the
surface on which it is mounted. HF05 is passive, using thermopile and
thermocouple sensors. The thermopile generates a small output voltage
proportional to the heat flux. HF05 can only be used in combination with a
suitable measurement system. The sensor should be used in accordance with the
recommended practices of ASTM.
Table 3.1 Specifications of HF05 (continued on next page)
Sensor type | industrial heat flux sensor |
---|---|
Sensor type according to ASTM | heat flow sensor or heat flux transducer |
Heat flux sensor | thermopile |
Measurand | heat flux |
Measurand in SI units | heat flux density in W/m2 |
Measurement range | -6000 to 6000 W/m2 |
Temperature sensor | thermocouple type K |
Temperature sensor specification | ANSI MC96.1-1982 / EN 60584 |
Measurand | temperature |
Measurand in SI units | temperature in °C |
Measurement function / required programming | 0 = U/S |
Sensitivity range | 10 to 25 x 10.6 V/(W/m2) |
Recommended number of sensors | 2 per measurement location |
Sensitivity (nominal) | 15 x 10.6 V/(W/m2) |
Response time (95 %) | 300 s (nominal) |
Directional sensitivity | heat flux from the side flush with the flanges |
(marked X) to the opposite side generates a positive voltage output signal
Expected voltage output| multiply the sensitivity by the maximum expected heat
flux
Required readout| heat flux sensor: 1 x differential voltage channel or 1 x
single-ended voltage channel temperature sensor: 1 x Type K differential
thermocouple channel or 1 x Type K single-ended thermocouple channel both with
input resistance > 106 Q
Rated operating temperature range| -30 to +170 °C
IP protection class| IP67
Rated operating relative humidity range| 0 to 100 0/0
Required sensor power| zero (passive sensors)
Temperature dependence| < 0.1 %/°C
Non-stability| < 1 %/yr (for typical use)
Sensor diameter| 40 x 10•3m
Sensor thickness| 5.0 x 10-3 m
Heat flux sensor resistance (nominal)| 3 SI
Heat flux sensor cable resistance| 0.2 SI/m
Temperature sensor resistance| 3 Slim
Table 3.1 Specifications of HF05 (started on the previous page, continued on the next page)
Standard cable length (see options) | 3 m |
---|---|
Cable diameter | 4 x 10-3 m |
Marking | 1 x engraving on the sensor side, showing the serial number |
1 x sticker at cable end, wrapped around the sensor cable, showing serial number.
Gross weight including 3 m cable| approx. 0.5 kg
Net weight including 3 m cable| approx. 0.5 kg
INSTALLATION AND USE|
Standards governing the use of the instrument| ASTM C1041-85 (2007) Standard
Practice for In-Situ Measurements of Heat Flux in Industrial Thermal
Insulation Using Heat Flux Transducers
Orientation| the side flush with the flanges (marked X) must be in contact
with the object on which the sensor is mounted
Installation| see recommendations in this user manual. Avoid mechanical force
on the flanges, sensor body, and sensor-to-cable transition.
Cable extension| see options: longer cable, extension cable, and connectors
Optional connectors on HF05 cable and extension cable| LEMO brand, 12 x 10-3 m
outer diameter
CALIBRATION|
Calibration traceability| to SI units
Product certificate| included
(showing calibration result and traceability)
Calibration method| method HFC, using a dedicated HF05 adapter, according to
ASTM C1130
Calibration hierarchy| From SI through international standards and through an
internal mathematical procedure
Calibration uncertainty| ± 10 % (k = 2)
Recommended recalibration interval| 2 years
Calibration reference conditions| 20 °C, heat flux of 350 W/m2, thermal
conductivity of the surrounding environment 0.0 W/(m•K)
Validity of calibration| based on experience the instrument sensitivity will
not change during storage. During use the instrument’s “non-stability”
specification is applicable.
Field calibration| is possible by comparison to a calibration reference
sensor. Usually mounted side by side. Preferably reference and field sensor of
the same model and brand. The typical duration of the test is> 24 h.
Temperature sensor tolerance class| IEC Tolerance class EN60584-2: Type K,
class 2
Temperature sensor error limits| ASTM E230-ANSI MC96.1: Type K, standard
limits
Table 3.1 Specifications of HF05 (started on previous 2 pages)
MEASUREMENT ACCURACY|
---|---
Uncertainty of the measurement| statements about the overall measurement
uncertainty can only be made on an individual basis. see the chapter on uncertainty evaluation.
VERSIONS / OPTIONS|
Order code| HF05 / cable length in m
Longer cable| longer cable (specify total cable length in m)
EC type-examination certificate (ATEX)| II 2 G Ex db HC T6
Extension cable| extension cable with 2 connectors matching cable connector
and chassis connector (specify cable length in m)
Connector| connector at HF05 cable end
Chassis connector| chassis connector with internal wiring
(colour code of wiring identical to cable colour code)
3.2 Dimensions of HF05
- engraved serial number
- non-object side
- object side (flush with mounting flanges)
- location temperature sensor (in body)
- side flush with mounting flanges is engraved with marker ‘X’
Standards and recommended practices for use
HF05 should be used in accordance with the recommended practices of ASTM.
4.1 Heat flux measurement in industry
Many HF05 sensors measure industrial walls and metal surfaces, estimating the installation’s energy balance and the thermal transmission of walls. Typically the total measuring system consists of multiple heat flux- and temperature sensors. In many cases, heat flux sensors are used for trend monitoring. In such cases, reproducibility is more important than absolute measurement accuracy.
Figure 4.1.1 Example of an industrial heat flux sensor mounted on a
boiler wall using tack-welded threads and spring-loaded bolts. The sensor is
mounted on a well-prepared flat surface. Cabling must be provided with strain
relief.
Table 4.1.1 contains a listing of applicable standards. We recommend users
purchase the latest version of the standard.
4.1.1 Applicable standards
Table 4.1.1 Standards with recommendations for instrument use in industry|
---|---
STANDARDS FOR INSTRUMENT USE FOR BUILDING ENVELOPE THERMAL RESISTANCE
MEASUREMENT|
ASTM STANDARD| EQUIVALENT ISO STANDARD
ASTM C1041-85 (2007) Standard Practice for In-Situ Measurements of Heat Flux
in Industrial Thermal Insulation Using Heat Flux Transducers.| Not available
Installation of HF05
5.1 Site selection and installation in the industry
Table 5.1.1 Recommendations for installation of HF05 heat flux sensors
Location| choose a location that is representative of the process that is
analyzed if possible, avoid exposure to the sun, rain, etc. do not expose to
drafts and lateral heat fluxes do not mount in the vicinity of thermal
bridges, cracks, heating or cooling devices, and fans
---|---
Performing a representative measurement / recommended number of sensors| we
recommend using > 2 sensors per measurement location. This redundancy also
improves the assessment of the measurement accuracy
Orientation| mount with the flanges flush with the object, see figure 5.1.1.
Mounted on vertical surfaces, the cable exit from the sensor should point
down.
Surface cleaning and leveling| create a clean and smooth surface with a
diameter of 80 x 10-3 m, so that the air gap between sensor and object surface
is less than 0.2 x 10-3 m
Mechanical mounting: Avoid strain on the sensor to cable transition| the
sensor-to-cable transition is vulnerable. during installation as well as
operation, the user should provide proper strain relief of the cable so that
transition is not exposed to significant force. first, install the cable
including strain relief, and after that install the sensor.
Mechanical mounting: using the mounting flanges| the sensor body withstands
only limited pressure and strain. users should not exert significant
mechanical force on the flanges. tack-weld or screw M6 thread to the surface
on which HF05 is mounted at a hart-to-hart distance of 64 x10-3 m. Bolts
holding the sensor should be used for positioning and for loose fixation only
and should be spring-loaded to guarantee good sensor to surface contact
without exerting too much force.
Permanent installation| for long-term installation fill up the space between
sensor and object with silicone construction sealant, silicone glue or
silicone adhesive, which can be bought in construction depots. Use this in
combination with the spring-loaded threads. we discourage the use of thermal
paste because it tends to dry out. silicone glue is more stable and reliable.
Signal amplification| see the paragraph on an electrical connection
Figure 5.1.1 Installation of HF05
(1+3) spring-loaded bolts
(2) smooth 80 x 10-³m diameter area for mounting HF05
(4+5) cable strain relief
Figure 5.1.2 Installation of HF05
(1) spring loaded M6 thread
(2) optional silicone glue between sensor body and object
(3) object to be measured
Figure 5.1.3 Installation of HF05
- engraved serial number
- HF05 side of object to be measured, flush with flanges
- heat flux generating a positive signal
- engraved with marker ‘X’
5.2 Electrical connection
A heat flux sensor should be connected to a measurement system, typically a
so-called datalogger. HF05 is a passive sensor that does not need any power,
neither for the heat
flux sensor nor for the temperature sensor. Cables may act as a source of
distortion, by picking up capacitive noise. We recommend keeping the distance
between a datalogger
or amplifier and the sensor as short as possible. For cable extension, see the
appendix on this subject.
Table 5.2.1 The electrical connection of HF05. The shield is not connected to the stainless steel sensor body
WIRE|
---|---
Red| heat flux signal [+]
Black| heat flux signal [−]
Green| thermocouple type K [+]
White| thermocouple type K [−]
Blank| shield
5.3 Requirements for data acquisition/amplification
The selection and programming of dataloggers is the responsibility of the
user. Please contact the supplier of the data acquisition and amplification
equipment to see if directions for use with the HF05 are available.
Table 5.3.1 Requirements for data acquisition and amplification equipment
for HF05 in the standard configuration
Capability to measure small voltage signals| preferably: < 5 x 10-6 V
uncertainty Minimum requirement: 20 x 10-6 V uncertainty (valid for the entire
expected temperature range of the acquisition / amplification equipment)
---|---
__
Capability for the data logger or the software
| __
to store data, and to perform division by the sensitivity to calculate the
heat flux.
Φ = U/S (Equation 0.1)
Capability to measure thermocouple type K| preferably: measurement
uncertainty within ± 3 °C
Data acquisition input resistance| > 1 x 106 Ω
Open circuit detection (WARNING)| open-circuit detection should not be
used, unless this is done separately from the normal measurement by more than
5 times the sensor response time and with a small current only. Thermopile and
thermocouple sensors are sensitive to the current that is used during open
circuit detection. The current will generate heat, which is measured and will
appear as a temporary offset.
Maintenance and troubleshooting
6.1 Recommended maintenance and quality assurance
HF05 measures reliably at a low level of maintenance. Unreliable measurement
results are detected by scientific judgment, for example by looking for
unreasonably large or
small measured values. The preferred way to obtain a reliable measurement is a
regular critical review of the measured data, preferably checking against
other measurements.
Table 6.1.1 Recommended maintenance of HF05. If possible the data analysis is done on a daily basis.
MINIMUM RECOMMENDED HEAT FLUX SENSOR MAINTENANCE
| INTERVAL| SUBJECT| ACTION
1| 1 week| data analysis| compare measured data to the maximum possible or
maximum expected heat flux and to other measurements for example from nearby
or redundant instruments. Historical seasonal records can be used as a source
for expected values. Look for any patterns and events that deviate from what
is normal or expected. Compare to acceptance intervals.
2| 6 months| inspection| inspect cable quality, inspect mounting, inspect the
location of installation look for seasonal patterns in measurement data
3| 2 years| recalibration| recalibration by comparison to a calibration
standard instrument in the field, see following paragraphs. recalibration by
the sensor manufacturer
4| | lifetime assessment| judge if the instrument will be reliable for another
2 years, or if it should be replaced
6.2 Troubleshooting
Table 6.2.1 Troubleshooting for HF05
General| Inspect the sensor for any damage. Inspect the quality of
mounting/installation. Inspect if the wires are properly attached to the data
logger. Check the condition of the cable.
Inspect the connection of the shield (typically connected at the datalogger
side). Check the datalogger program in particular if the right sensitivity is
entered. HF05 serial number is engraved on the side of the sensor body. The
sensitivity can be found on the calibration certificate.Check the electrical
resistance of the heat flux sensor between the black [-] and red [+] wires and
the thermocouple between the green [+] and white [-] wires. Use a multimeter
at the 100 Ω range. Measure the sensor resistance first with one polarity,
then reverse the polarity. Take the average value. Typical resistance should
be the nominal sensor resistance of 3 Ω for the thermopile sensor plus 0.2 Ω/m
(resistance per meter cable) for the total resistance of two wires (back and
forth added). For the thermocouple work with 3 Ω/m resistance per meter cable.
Infinite resistance indicates a broken circuit; zero or a lower than 1 Ω
resistance indicates a short circuit.
---|---
The sensor does not give any signal| Check if the heat flux sensor reacts to
heat: put the multimeter at its most sensitive range of DC voltage
measurement, typically the 100 x 10-3 VDC range or lower. Expose the sensor
heat, for instance touching it with your hand. The signal should read > 2 x
10-3 V now. Exposing the side flush with flanges should generate a positive
signal, doing the same at the opposite side, the sign of the output voltage
reverses. Also look at the reaction of the thermocouple to heat. Check the
reaction of the thermocouple sensor to heat. Check the data acquisition by
replacing the sensor with a spare unit.
The sensor signal is unrealistically high or low| Check the cable condition
looking for cable breaks. Check the data acquisition by applying a 1 x 10-6 V
source to it in the 1 x 10-6 V range. Look at the measurement result. Check if
it is as expected. Check the data acquisition by short-circuiting the data
acquisition input with a 10 Ω resistor. Look at the output. Check if the
output is close to 0 W/m2.
The sensor signal shows unexpected variations| Check the presence of strong
sources of electromagnetic radiation (radar, radio). Check the condition and
connection of the shield. Check the condition of the sensor cable. Check if
the cable is not moving during the measurement.
6.3 Calibration and checks in the field
The recommended calibration interval of heat flux sensors is 2 years.
Recalibration of field heat flux sensors is ideally done by the sensor
manufacturer.
On-site field calibration is possible by comparison to a calibration reference
sensor, usually mounted side by side, alternatively mounted on top of the
field sensor.
Hukseflux main recommendations for field calibrations are:
- to compare to a calibration reference of the same brand and type as the field sensor
- to connect both to the same electronics so that electronics errors (also offsets) are eliminated.
- to mount all sensors on the same platform so that they have the same body temperature.
- typical duration of test: > 24 h
- typical heat fluxes used for comparison: > 20 W/m², preferably > 200 W/m²
- to correct deviations of more than ± 10 %. Lower deviations should be interpreted as acceptable and should not lead to a revised sensitivity.
Appendices
7.1 Appendix on uncertainty evaluation
If the user wants to perform accurate absolute measurements, as opposed to relative measurements, we recommend that the user calibrates sensors under his own responsibility under “simulated service conditions”, and make his own correction for systematic errors and uncertainty evaluation.
The uncertainty of measurement with HF05 is a function of:
- calibration uncertainty
- differences between reference conditions during calibration and measurement conditions, for example, uncertainty caused by the temperature dependence of the sensitivity
- the duration of sensor employment (involving the non-stability)
- application errors: the measurement conditions and environment in relation to the sensor properties, the influence of the sensor on the measurand, the representativeness of the measurement location
If the user knows the total power generated by a process the user may
calibrate the heat flux measurement by comparison of heat fluxes multiplied by
surface areas to the total
generated power. Some users apply (temporary) electrical heaters to calibrate
the sensors.
7.2 Appendix on cable extension / replacement
HF05 is equipped with one cable. Keep the distance between the data logger or
amplifier and sensor as short as possible. Cables may act as a source of
distortion by picking up
capacitive noise. In an electrically “quiet” environment, the HF05 cable may
be extended without problem to 50 meters. If done properly, the sensor signal,
although small, will
not significantly degrade because the sensor resistance is very low (which
results in good immunity to external sources) and because there is no current
flowing (so no resistive
losses). Cable and connection specifications are summarised in table 7.2.1.
Table 7.2.1 Preferred specifications for cable extension of HF05
__ Cable | __ Hukseflux HF05 cable |
---|---|
__ Extension | __ Use Hukseflux extension cable with 2 connectors matching |
cable connector and chassis connector (specify cable length in m)
Use Hukseflux HF05 cable connector on the HF05 cable to a connector of the
extension cable with 2 connectors
Use Hukseflux chassis connector
Outer diameter| 4 x 10-3 m
Length| cables should be kept as short as possible, in any case, the
total cable length should be less than 50 m
7.3 Appendix on calibration hierarchy
HF05 factory calibration is traceable from SI through international standards
and through an internal mathematical procedure that corrects known errors. The
formal
traceability of the generated heat flux is through voltage and current to
electrical power and electric power and through the length to the surface
area.
The Hukseflux HFC method follows the recommended practice of ASTM C1130. It relies on a thin heater apparatus according to principles as described in paragraph 4 of ASTM C1114-06, in the single-sided mode of operation described in paragraph 8.2 and in ASTM C1044.
7.4 EU declaration of conformity
We,| Hukseflux Thermal Sensors B.V.
Delftechpark 31
2628 XJ Delft
The Netherlands
---|---
in accordance with the requirements of the following directive:
2014/30/EU
The Electromagnetic Compatibility Directive hereby declare under our sole
responsibility that:
Product model: | HF05 |
---|---|
Product type: | Industrial heat flux sensor |
has been designed to comply and is in conformity with the relevant sections and applicable requirements of the following standards:
Emission: | EN 61326-1 (2006) |
---|---|
Immunity: | EN 61326-1 (2006) |
Emission: | EN 61000-3-2 (2006) |
Emission: | EN 61000-3-3 (1995) + A1 (2001) + A2 (2005) |
Report: | 08C01340RPT01, 06 January 2009 |
Eric HOEKSEMA
Director
Delft
September 08, 2015
© 2021, Hukseflux Thermal Sensors B.V.
www.hukseflux.com
Hukseflux Thermal Sensors B.V. reserves the right to change specifications
without notice.
HF05 manual v2126
Copyright by Hukseflux | manual v2126 |
www.hukseflux.com |
info@hukseflux.com
References
- Market leader in solar radiation & heat flux measurement
- Market leader in solar radiation & heat flux measurement
- #1 in heat flux sensors, heat flux measurement | Hukseflux
- HFP01 heat flux plate | Hukseflux | the world's most popular heat flux sensor
- IHF01 industrial heat flux sensor | Hukseflux
- IHF02 | Hukseflux | ultra sensitive industrial heat flux sensor
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>