Turnils North America AMP15WSSU Surface Mounted Wall Switch Instruction Manual

June 5, 2024
Turnils North America

North America AMP15WSSU Surface Mounted Wall Switch
Instruction Manual

Fields of Application Specifications

Voltage 3V (CR2430)
Radio Frequency 433.92 MHz Bi-directional
Transmitting Power 10 milliwatt
Operating Temperature 14°F to 122°F (-10°C to 50°C)
RF Modulation FSK
Lock Function Yes
IP Rating IP20
Transmission Distance up to 200m (outdoor)

Safety Instructions

  1. Do not expose the motor to humid, damp, or extreme temperature conditions.
  2. Do not drill into the motor.
  3. Do not cut the antenna. Keep it clear from metal objects.
  4. Do not allow children to play with this device.
  5. If the power cable or connector is damaged, do not use it.
  6. Ensure the correct crown and drive adaptor are used.
  7. Ensure the power cable and aerial is clear and protected from moving parts.
  8. Cable routed through walls should be properly isolated.
  9. The motor is to be mounted in a horizontal position only.
  10. Before installation, remove unnecessary cords and disable equipment not needed for powered operation.
  11.  Installation and programming should be performed by a qualified professional. Use or modification outside the scope of these instructions may void the warranty.

Button Instructions

Replace/Install CR2430 Battery

a. Unlock the battery cover and take the cover out.
b. Install battery (CR2430) with positive (+) side facing up.
c. Gently put the cover back and switch to lock position.

Advanced Setting – Disable Limit Setting

a. Press and hold “Stop” button more than 15s. Wall Switch will show “L ” (lock).
b. In the next 10s, press one “P2” button on the back of Wall Switch. Wall Switch will show “o”, then the Wall Switch switches to “Lock” mode to disable the following commands:
– Change Motor Direction
– Setting the Upper and Lower Limit
– Adjust Limit
– Roller Mode or Sheer Mode
c. Press and hold the “Stop” button more than 15s. Wall Switch will show “U” (unlock).
d. In the next 10s, press one “P2” button on the back of Wall Switch. Wall Switch will show “o”. The Wall Switch now switches to “Unlock” mode,you can access all control functions.
*This advanced feature is intended to be used after all shade programming is completed. User Mode will prevent accidental or unintended changing of limits.

Channel Options

Select A Channel
a. Press the “-” button on the wall switch to select a lower channel.
b. Press the “+” button on the wall switch to select a higher channel.

Hide Unused Channels
a. Press and Hold (about 3 sec) the “-” and “+” buttons simultaneously until the wall switch displays “C” (channel).
b. Press the “-” or “+” button to select the required quantity of channels (between 1 to 15).
c. Press the “Stop” button to confirm selection. The LED will display “o” (OK) once to confirm selection.

Essential Settings
The steps in factory mode must be completed to ensure proper operation.
* AMPCEL and AMPTILT motors DO NOT BEEP.

1. Pair / Unpair Wall Switch

a. Press the “P1” button (about 2 sec) on the motorhead until the motor jog x1 and beeps x1.
b. In the next 10 secs, press and hold the “Stop” button on the wall switch until the motor jog x2 and beeps x3. * Repeat the same procedure to unpair the wall switch.
2. Change Motor Direction (if necessary)

Press the “Up” or “Down” button to check if the shade moves in the desired direction. If you need to reverse the direction, press and hold (about 2 sec) the “Up” and “Down” buttons simultaneously until the motor jog x1 and beeps x1. *The operation is only valid when there are no limits. If the motor has already set the upper and lower limit, then you can only switch direction by pressing the “P1” button (about 10 sec) on the motor head until the motor jog x3 and beeps x3.
3. Setting the Upper and Lower Limits
3.1 Set Upper Limit
a. Press the “Up” button to raise the shade, then press the “Stop” button when it is in the desired upper limit.
b. Press and hold (about 5 sec) the “Up” and “Stop” buttons simultaneously until the motor jog x2 and beeps x3.

3.2 Set Lower Limit

a. Press the “Down” button to lower the shade, then press the “Stop” button when it is in the desired lower limit.
b. Press and hold (about 5 sec) “Down” and “Stop” buttons simultaneously until motor jog x2 and beep x3.
*If you exit the limit setting status before you finish the limit settings, the motor will take the previous existing limits.

Adjust Limits

4.1 Adjust the Upper Limit
a. Press and hold (about 5 sec) the “Up” and “Stop” buttons simultaneously until the motor jog x1 and beeps x1. b. Use the “Up” button to raise the shade to the desired highest position, and use the “Up” or “Down” button to do the final adjustment if necessary.
c. Press and hold (about 5 sec) the “Up” and “Stop” buttons simultaneously until the motor jog x2 and beeps x3.
4.2 Adjust the Lower Limit
a. Press and hold (about 5 sec) “Down” and “Stop” buttons simultaneously until motor jog x1 and beep x1. b. Use the “Down” button to lower the shade to the desired lowest position, and use the “Up” or “Down” button to do the final adjustment if necessary.
c. Press and hold (about 5 sec) the “Down” and “Stop” buttons simultaneously until the motor jog x2 and beeps x3.

Favorite Position

5.1 Set Favorite Position
a. Use the “Up” or “Down” button to move the shade to desired Favorite position.
b. Press and hold (about 2 sec) one “P2” button on the back of the wall switch until the motor jog x1 and beeps x1. c. Press and hold (about 2 sec) the “Stop” button until the motor jog x1 and beeps x1.
d. Once more, press and hold (about 2 sec) the “Stop” button until the motor jog x2 and beeps x3.
5.2 Send Shade to Favorite Position Press and hold (about 2 sec) the “Stop” button, the motor will move to the Favorite position.
5.3 Delete Favorite Position
a. Press and hold (about 2 sec) one “P2” button until the motor jog and beeps x1. b. Press and hold (about 2 sec) the “Stop” button until the motor jog and beeps x1.
c. Once more, press and hold (about 2 sec) the “Stop” button until the motor jog x1 and long beep x1.

Roller Mode and Sheer Mode

6.1 Roller Shade Mode – continue movement after a short press – Default Mode

a. Press and hold (about 5 sec) the “Up” and “Down” buttons simultaneously until the motor jog x1.
b. Press and hold (about 2 sec) the “Stop” button until the motor jog x2 and beeps x3.
6.2 Sheer Shade Mode – jog movement after a short press (continue movement after a long press)3 a. Press and hold (about 5 sec) the “Up” and “Down” buttons simultaneously until the motor jog x1.
b. Press and hold (about 2 sec) the “Stop” button until the motor jog x1 and beeps x1.

Add or Remove Additional Wall Switch

7.1 Using Current Wall Switch
a. On the current wall switch, press and hold (about 2 sec) one “P2” button until the motor jog x1 and beeps x1.
b. Once more, on the current wall switch, press and hold (about 2 sec) one “P2” button until the motor jog x1 and beeps x1. c. On the New wall switch, press and hold (about 2 sec) one “P2” button until the motor jog x2 and beeps x3.
*Repeat the same procedure to remove the additional wall switch.

7.2 New Wall Switch Control
Follow instructions under section 1. Pair / Unpair Wall Switch

Adjust Motor Speed

8.1 Acceleration Speed

a. Press one “P2” button until the motor jog x1 and beeps x1.
b. Press the “Up” button until the motor jog x1 and beeps x1.
c. Once more, press the “Up” button until the motor jog x2 and beep x1.
8.2 Deceleration Speed

a. Press one “P2” button until the motor jog x1 and beeps x1.
b. Press the “Down” button until the motor jog x1 and beeps x1.
c. Once more, press the “Down” button until the motor jog x2 and beeps x1.
*If the motor has no response, it already has a Maximum or Minimum speed.

Declarations

U.S. Radio Frequency FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

ISED RSS Warning:

This device complies with Innovation, Science, and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Quick Index

Settings Steps
Pairing P1 (hold down for 2s) > Stop (hold down for 2s)
Switch Rotating Direction Up + Down (hold down for 2s)
Setting Upper & Lower Limits Upper Limit: Up (hold down for 2s) > Up + Stop

(hold down for 2s)
Lower Limit: Down (hold down for 2s) > Down + Stop (hold down for 2s)
Add / Remove Favorite Position| P2 > Stop > Stop
Roller Mode & Sheer Mode Switch| Up + Down (hold down for 5s) > Stop
Adjust Limits| Upper Limit: Up + Stop (hold down for 5s) > Up or Down > Up + Stop (hold down for 2s)
Lower Limit: Down + Stop (hold down for 5s) > Up or Down > Down + Stop (hold down for 2s)
Pair / Unpair Additional Emitter| P2 (existing) > P2 (existing) > P2 (new)
Speed Regulation| Acceleration: P2 > Up > Up
Deceleration: P2 > Down > Down

Troubleshooting

Issues

| Possible Causes|

Solution

---|---|---
The motor has no response| Battery in motor is depleted| Recharge with compatible AC adaptor and check connection and positioning of solar PV panel
Insufficient charging from Solar PV Panel| Check connection and orientation of solar PV panel
The wall switch battery is discharged| Replace battery
The battery is inserted incorrectly into wall switch| Check battery polarity
Radio interference/shielding| Ensure wall switch and the antenna on the motor are positioned away from metal objects
The receiver distance is too far from the wall switch| Move the wall switch to a closer position
Power failure| Check the power supply to the motor is connected and active
Incorrect wiring| Check that wiring is connected correctly (refer to motor installation instructions)
Motor beeps 10 times when in use| Battery voltage is low / PV (solar
panel issue)| Recharge with AC adapter or check connection and positioning of solar PV panel
Cannot program a single motor (multiple motors respond)| Multiple motors are paired to the same channel.| Always reserve an individual channel for programming functions
SYSTEM BEST PRACTICE – Provide an extra 15 channel remote in your multi-motor projects that provide individual control for each motor for programming purposes
Place all other motors into sleep mode (Press the “P1” button (about 6 sec) on the motorhead until the motor jog x2 and beep x2).

Please scan the QR code to see more AMP™ product information

Do not dispose of in the general waste.