INSTALLATION & MAINTENANCE MANUAL
AC65136EM / AC65158EM / AC651581EM
/ AC65170EM / AC65236EM / AC65258EM
/ AC652581EM / AC65270EM
GENERAL INSTRUCTIONS
These instructions should be read carefully and retained after installation by
the end user for future reference and maintenance.
These instructions should be used to aid the installation of the following
products:
AC65136EM / AC65158EM / AC651581EM / AC65170EM / AC65236EM / AC65258EM
/AC652581EM / AC65270EM
SAFETY
- This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician.
- Please isolate mains prior to installation or maintenance
- Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the circuit cable, fuse, or circuit breaker
- Please note the IP (Ingress Protection) rating of this luminaire/product when deciding the location for installation
- This product is Class I and must be earthed.
- This product is IP65-rated.
INSTALLATION
-
Provide power to the required point of installation
-
Unfasten the clips on either side of the fitting (see Fig. 1) and remove the diffuser
-
Remove the gear tray from the baseplate by pinching the clips at two locations (see Fig. 2)
-
Mark the location of the fixing holes and drill the holes ensuring not to infringe on any gas/water pipes or electrical cables. Fixing centers are shown in Fig. 3
-
Drill out one of the 20mm drilling guides and fit the compression gland provided
-
Feed the mains cable into the luminaire, and tighten the compression gland ensuring a tight seal is made
-
To ensure the correct polarity is observed, carefully wire as shown in Fig. 4
-
Ensure the battery is connected via the plug and socket to the emergency inverter.
-
Replace the gear tray.
-
Fit an appropriate T8 fluorescent tube.
-
Replace the diffuser.
-
Switch on and check for correct operation, ensuring the green indicator LED is illuminated.
-
We recommend, on commissioning the installation, a minimum charge period of 24 hours before carrying out an emergency duration test.
-
If the batteries have been left in a discharged state for an extended period, we recommend that one or more charge and discharge cycles are completed which should help to restore the battery capacity.
WARNING
This product must be disconnected from the circuit if subjected to any high
voltage or insulation resistance testing. Irreparable damage will occur if
this instruction is not followed.
GENERAL
This product contains a control gear that can be replaced by a professional.
Clean the external surfaces with a damp cloth using a mild solution of
detergent and warm water only, do not use aggressive cleaning products or
solvents that may damage the product.
Do not use any source of high-pressure washers to maintain or clean this
luminaire.
Installing in areas where the temperature consistently drops below 0°C may
shorten the battery life.
This product is non-dimmable.
This product should be dismantled for disposal when it reaches the end of its
life. Please see the website for dismantling instructions.
This product should be recycled in the correct manner when it reaches the end
of its life. Check local authorities for where facilities exist.
The batteries in this luminaire are Nickel Cadmium and must be disposed of
correctly. Please contact the local authorities for the disposal of this toxic
waste.
WARRANTY
This product has a warranty of 3 years (excluding battery) from the date of
purchase. Failure to install this product in accordance with the current
edition of the IEE Wiring Regulations (BS7671), improper use, or removal of
the batch code will invalidate the warranty. If this product should fail
within its warranty period, it should be returned to the place of purchase for
a free-of-charge replacement. ML Accessories does not accept responsibility
for any installation costs associated with the replacement product. Your
statutory rights are not affected. ML Accessories reserve the right to alter
product specification without prior notice.
TESTING FOR EMERGENCY LUMINAIRES
Recommended routine test procedure in accordance with BS5266
- Daily check – check LED charge indicator is illuminated
- Monthly functional test – simulate a mains supply failure for approx. 30 seconds by operation of a key switch or switching off the circuit breaker. Ensure normal supply is restored after the test and ensure the charge indicator is illuminated
- Annual three-hour duration test – simulate a mains supply failure for a three-hour continuous test by operation of a key switch or switching off the circuit breaker. Ensure normal supply is restored after the test and ensure the charge indicator is illuminated
- If the luminaire fails any of the above tests, please contact a qualified electrician. See below for the test record sheet.
https://www.mlaccessories.co.uk/contact-usML
Accessories Limited LU5 4LT
www.mlaccessories.co.uk
DCAUG21_V2
Documents / Resources
|
Knightsbridge AC65270EM 230V IP65 2x70W 6ft Twin HF Non-Corrosive Fluorescent
Fitting
[pdf] Instruction Manual
AC65136EM, AC65158EM, AC651581EM, AC65170EM, AC65236EM, AC65258EM, AC652581EM,
AC65270EM, 230V IP65 2x70W 6ft Twin HF Non-Corrosive Fluorescent Fitting,
AC65270EM 230V IP65 2x70W 6ft Twin HF Non-Corrosive Fluorescent Fitting, IP65
2x70W 6ft Twin HF Non-Corrosive Fluorescent Fitting, 2x70W 6ft Twin HF Non-
Corrosive Fluorescent Fitting, 6ft Twin HF Non-Corrosive Fluorescent Fitting,
Non-Corrosive Fluorescent Fitting, Fluorescent Fitting
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>