VONETS VBG1200 Industrial Mini Dual Band 2.4GHz/5GHz WiFi Bridge/Router/WiFi to Ethernet Adapter User Guide

June 5, 2024
VONETS

VONETS VBG1200 Industrial Mini Dual Band 2.4GHz/5GHz WiFi

Bridge/Router/WiFi to Ethernet Adapter

Declaration

Copyright © 2019 Shenzhen HouTian Network Communication Technology Co.,Ltd All rights reserved, with retained ownership Without Shenzhen HouTian Network communication Technology Co.,Ltd written authorization, any company or person can’t copy, writer or translate part or all contents. Can’t do commodity distribution for any commercial or profitable purposes by anyways(electricity, mechanical, photoprint, record or othe r methods).
VONETS is the registered trademark of Shenzhen HouTian Network Communication Technology Co.,Ltd. The other all trademarks or registered trademarks mentioned in this document belong to the individual owners. The product specifications and information technology mentioned in this manual are just for reference, if any updates, without other notice. Except for special agreements, this manual is just for user guidance, any statements, information and so on in this manual can’t constitute the warranty of any forms.

Form 1

Transmission Distance Parameters Form

Model| No-barrier point to point Transmission

Distance

| Transmission Rate (Mbps)| Band
VM300| 80m–100m| 300|
VM5G/VBG1200| 600m–700m| 300+900| 5G

Form 2

Power Supply Parameters List

Model| Power Supply Voltage| Input Power| Typical Power Supply
VM300| DC5–15V| ≥5W| 5V/1A
VM5G/VBG1200| DC5–15V| ≥10W| 5V/2A

Chapter 1 Application Mode

Bridge + Repeater Mode
There are three application modes for the bridge mode of VONETS module/WiFi product: WiFi repeater, WiFi bridge and WiFi AP.

  • WiFi Repeater: VONETS module/WiFi product as WiFi Repeater, it must be configured to source WiFi hostpot parameters, can be used to extend the wireless signal coverage of existing APs or wifi router .VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG1
  • WiFi Bridge: VONETS module/WiFi product as WiFi bridge, it must be configured to source WiFi hotspot parameters, can be used for devices only with Ethernet ports to access wireless networks.  VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG2
  • WiFi-AP: VONETS module/WiFi product as WiFi AP, it can achieve wireless access to wired LAN, no configuration required, plug and play.  VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG3

Router Mode

  • VONETS module/WiFi product as WiFi router The Ethernet port of the VM300 module defaults to the WAN port. The Ethernet cable defaults to the LAN port. WAN and LAN ports are interchangeable.  VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG4
  • The Ethernet cable of the VM5G module/VBG1200 WiFi product defaults to a LAN port, you must set “WAN/LAN interchange” so that the Ethernet cable is WAN port to use the broadband dialing function. VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG5
  • VONETS module/WiFi product is used as a wireless router. A WAN port can be set to connect to the WiFi hotspot for use as a secondary router. VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG6

Chapter 2 Bridge+Repeater Mode Configuration Instruction

Method 1: Use the mobile phone APP VCC configuration
Use the Android system (IOS system is not supported temporarily) mobile browser to scan the QR code below to download the VCC configuration software, and then enter the VCC interface to scan the QR code on the back of the bridge for code scanning connection and configuration (the software version of the bridge shall not be less than 3.2.21.7.13);

Method 2: Log in to the device’s Web configuration page to configure
Device Connection:
Power on VONETS module/WiFi product by 5V/2A power supply, then connect to PC, there are two connection ways as below:

  • Computer is wired connected to LAN port of VONETS module/WiFi product;
  • B. The computer wirelessly connects to the WiFi signal of VONETS module/WiFi product, its default hotspot parameters are as follows: WiFi SSID: VONETS_** (corresponding to VONETS device MAC address) WiFi password: 12345678

(After the WiFi parameters are configured, the WiFi will be disconnected, that is normal.)

Bridge+Repeater Application Configuration
The configuration steps of VONETS module/WiFi product for WiFi repeater and WiFi bridge are basically the same, so this manual combines the configuration instructions of the two application modes.

  1. After computer is connected to VONETS module/WiFi product, open browser, input configured page: http://vonets.cfg (or IP: 192.168.254.254), then press Enter;
  2. Input User name and Password in login page (both are “admin”), click “Login” button to enter configured page;
  3. “Scan Hotspots”, choose the source hotspots, click “Next”;
  4. Input “Source wireless hotspot password”, click “Apply”;
    • IP layer transparent transmission (factory default), transparent transmission of IP layer data, can meet most of WiFi bridge applications;
    • MAC layer transparent transmission, transparent transmission of all data above the MAC layer (link layer) and MAC layer, including IP layer data. MAC transparent transmission can solve some special applications for MAC layer encryption, such as GoPro camera, Cisco AP, Hikvision monitoring system, etc;
    • The option “The configuration parameters of WiFi repeater security is synchronized with source hotspot”is default ticked, it means the SSID of VONETS repeater is associated with the SSID of the source hotspot, and the WiFi password is the same as the password of the source hotspot;
    • Disable hotspot, if you select “Disable hotspot”on the right side of the SSID, the device will not transmit the corresponding hotspot and can only be used as a bridge application;
    • Advanced Setting,include Hot spot authentication match mode, WiFi Signal Motion Detection and SSA Signal strength alarm threshold,these options here can be kept unchanged, for instructions on this option, go to www.vonets.com and download the “V Series WiFi Bridge Advanced Features Instruction”;
  5. Click “Reboot”, VONETS module will connect to the configured WiFi hotspot automatically, if connection is successful, the WiFi LED light will flash quickly;

LED Light Form

Model| Blue Light| Green Light| Yellow Light
VM300| WiFi Connection Status Light| Ethernet Cable Connection Status Light| /

VM5G/VBG1200

| WiFi Connection Status Light| 5G WiFi Connection Status Light| Ethernet Cable Connection Status Light

  1. VONETS module/WiFi product is not connected to any hotspot, WiFi connection status light will flash quickly;
  2. VONETS module/WiFi product is connected to hotspot successfully, WiFi connection status light will quick flash;
  3. VONETS module/WiFi product is connected to hotspot successfully, but hotspot signal strength is less than 50% greater than 10%, WiFi status light will pause flash and flash;
  4. VONETS module/WiFi product is connected to hotspot failed, WiFi connection status light will flash slowly.

AP Application Configuration

VONETS module/WiFi product can be configured as an AP application. The wireless terminal device can connect to VONETS module/finished product hotspot to connect to the network; however, it is best to change its WiFi name and password for network security.

  1. Log in to the configuration page http://vonets.cfg (or IP: 192.168.254.254) in your computer browser, both user name and password are “admin”
  2. Revise WiFi name: Jump to “WiFi Repeater”—- “Basic Settings”, enter new WiFi name in “WiFi Repeater (SSID)”, click “Apply”;
    1. VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG16Revise WiFi password, in “WiFi Repeater”—-“WiFi Security”, enter new WiFi password in “Pass Phrase”, click “Apply”; VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG17
  3. “WiFi Tx Power” of VONETS module/WiFi product can be changed, jump to “System Settings”—- “Advance Settings”, choose suitable transmit power, then click “Apply”; VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG18
  4. Reboot device, jump to “System Settings”—- “Reboot Device”, click “Reboot”, when it is finished, all revised options will take effort. VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG19

Remark: When VONETS module/WiFi product connect to external network, its IP address will be changed. At this time, when log in configured page, we suggest you enter configured domain name: http://vonets.cfg. Or in Windows command window, enter the command: ping vonets.cfg, to get the IP address of the device, then log in configuration page by this IP address.

Router Mode Configuration Instruction

Change device mode
  1. Power on VONETS module/WiFi product by 5V/2A power supply, then connect to PC, there are two connection ways as below:

    • The computer is wired connected to LAN port of the VONETS module/WiFi product; VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG20
    • The computer wirelessly connects to the WiFi signal of VONETS module/WiFi product, its default hotspot parameters are as follows:
      WiFi SSID: VONETS_** (corresponding to VONETS device MAC address) WiFi password: 12345678. VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-
Adapter-FIG21
  2. After the computer is connected to the VONETS module/WiFi product, open browser, input configured page domain name: http://vonets.cfg (or IP: 192.168.254.254), then press Enter; VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG22

  3. Enter User name and Password in login page (both are “admin”), click “Login” button to enter configured page; VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG23

  4. In “Operating Mode”, change Device mode to “Router” mode, click “Apply” button;  VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG24

  5. Reboot device: go to “System Settings”– “Reboot device”, click the “Reboot”button, VONETS module/WiFi product will automatically switch to router mode. VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG25

WAN port setting

WAN/LAN exchange
In routing mode, the Ethernet port of VONETS module/WiFi product is divided into a WAN port and a LAN port, and WAN/LAN can be interchanged.
The Ethernet port of VM300 module defaults to WAN port. The Ethernet cable defaults to LAN port. If the interface mode is changed to “WAN/LAN exchange”, the Ethernet cable will be WAN port and the Ethernet port will be LAN port.(This option can keep unchanged); The Ethernet cable of VM5G/VBG1200 WiFi product defaults to LAN port, the interface mode must be changed to “WAN/LAN interchange” to make Ethernet cable to WAN port, click “Apply”, then reboot VONETS module/WiFi product. VONETS-VBG1200-Industrial-Mini-Dual-Band-
Ethernet-Adapter-FIG26

WAN Port connection method
By setting the WAN port of the router, you can change the network connection type according to the actual needs of the individual, there are three types of WAN port connections commonly used in the routing mode of the VONETS module/WiFi product: DHCP(Auto Config), PPPoE(ADSL) and WiFi. DHCP and PPPoE are wired connections, and the WAN port needs to be connected to the source network through a wired connection:

  • DHCP(Auto Config): WAN port connection type is selected as “DHCP(Auto Config)”, VONETS module/WiFi product will automatically obtain IP address from source network;
  • PPPoE(ADSL): WAN port connection type is selected as “PPPoE”, that is, ADSL virtual dialing mode requires ISP (Internet Service Provider) to provide an Internet account and password.
  • WiFi: WAN port connection type is selected as “WiFi”, VONETS module/WiFi product uses a built-in WiFi network card (used to connect to the source hotspot) as a WAN port, and all Ethernet ports as LAN ports, while providing WiFi hotspot functions.

WAN port wired connect network——DHCP
The default WAN port connection mode of VONETS is DHCP. The WAN port can automatically obtain an IP address after connecting with the source network. VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-
FIG27

WAN port wired connect network——PPPoE
In “WAN settings”, select “Basic settings”, change the connection type to “PPPoE (ADSL)”, then enter the Internet account and password provided by the ISP (Internet Service Provider), click the “Apply”button, and then reboot VONETS module/WiFi product, then can access to network. VONETS-VBG1200
-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG28

WAN port wireless connect network—- WiFi

  1. In “WAN Settings”, select “Basic Settings”, change Connection type to “WiFi”, then click “Scan Hotspots”to enter the scanning hotspot list. VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG29
  2. Choose the source hotspots, click “Next”; VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG30
  3. Input “Source wireless hotspot password”, click “Apply”
    • The option “The configuration parameters of WiFi repeater security is synchronized with source hotspot”is default ticked, it means the SSID of VONETS repeater is associated with the SSID of the source hotspot, and the WiFi password is the same as the password of the source hotspot;
    • Disable hotspot, if you select “Disable hotspot”on the right side of the SSID, the device will not transmit the corresponding hotspot and can only be used as a bridge application;
    • Advanced Setting,include Hot spot authentication match mode, WiFi Signal Motion Detection and SSA Signal strength alarm threshold,these options here can be kept unchanged, for instructions on this option, go to www.vonets.com and download the “V Series WiFi Bridge Advanced Features Instruction”; VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG31
  4. Click “Reboot”, VONETS module/WiFi product will connect to the configured WiFi hotspot automatically, if connection is successful, the WiFi LED light will flash quickly;(Please refer to Remark 1 for the description of the LED light.) VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG32

Remark: After VONETS module/WiFi product sets the WAN port to access the WiFi hotspot in the routing mode, its LAN port IP is still 192.168.254.254, and the terminal device also obtains the IP address of the same network segment, can login configuration page by 192.168.254.254 or http://vonets.cfg.

Set WiFi hotspot parameters

  1. Revise WiFi name: Jump to “WiFi Repeater”—- “Basic Settings”, enter new WiFi name in “WiFi Repeater (SSID)”, click “Apply”; VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG33
  2. Revise WiFi password, in “WiFi Repeater”—-“WiFi Security”, enter new WiFi password in “Pass Phrase”, click “Apply”; VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG34
  3. Reboot device, jump to “System Settings”—- “Reboot Device”, click “Reboot”, when it is finished, all revised options will take effort. VONETS-VBG1200-Industrial-Mini-Dual-Band-Ethernet-Adapter-FIG35

Appendix Frequently Asked Questions

  1. How to restore the factory default parameters of the VONETS module/WiFi product?
    Please refer to the information below to reset the factory default parameters of the VONETS module/WiFi product:
    VM300: http://www.vonets.com/serviceView.asp?D_ID=213
    VM5G: http://www.vonets.com/serviceView.asp?D_ID=306
    VBG1200: After the device is powered on for about 60 seconds, press and hold the Reset button for 5 seconds and then release, the blue indicator light will flash a few times, and then the device will automatically restore the factory default parameters (the restoring process takes about 80 seconds). During operation, the product cannot be powered down, otherwise, it may cause damage to the product.

  2. Does VONETS module/WiFi product support firmware upgrade, how to upgrade?
    VONETS module/WiFi product t supports firmware upgrade, and support online upgrade, please visit the website: www.vonets.com to refer to the related documents.

  3. The device WiFi hot spot can be found, but the smartphone or PC can’t connect to this device hotspot?

    • Reason 1. Some unexpected operation or power down, caused the destruction of device parameters. At this time, just need to reset the device to factory default parameters;
    • Reason 2. The device’s WiFi doesn’t work at the best channel, making the performance worse. At this time, you can try to change the source WiFi hot spot and this device’s WiFi channel to make the performance better;
    • Reason 3. The smartphone or PC hasn’t been configured with the correct WiFi password.
  4. The device has been configured with the source WiFi hot spot parameters, the smartphone or PC has connected to the device WiFi hot spot, but still doesn’t get internet?

    • First, check the status light to know the current state of the device, then according to the state of the device to analyze the fault reasons;

    • Reason 1. The distance between the device and the source WiFi hot spot is too long, causes communication performance degradation, and finally affect the user’s access to the Internet. At this time, just need to shorten the distance between the device and the source WiFi hot spot to solve this problem;

    • Reason 2. Some unexpected operation or power down caused the destruction of device parameters. At this time, just need to reset the device to factory default parameters;

    • Reason 3. The device WiFi doesn’t work at the best channel, make the performance worse. At this time, you can try to change the source WiFi hot spot WiFi channel to make it the same as the default channel of the device, the reboot the device, the device will automatically exchange to the same channel as the source WiFi hotspot, to make the performance better;

    • Reason 4. There are several WiFi hot spot around the device, WiFi channel mutual interference, make the performance worse. At this time, you can try to change
      the source WiFi hot spot and this device WiFi channel to make the performance
      better;

    • Reason 5. The configured source WiFi hot spot parameters are not correct. At this time, just need to configure the correct parameters then reboot the device;

  5. The smart phone or PC has been connected the device by WiFi or Ethernet cable, but user can’t log in the device WEB page, or after log in the WEB it shows error?

    • Reason 1. The users don’t use the browser recommended by VONETS(IE,Google Chrome, Safari, the mobile phone browser);
    • Reason 2. The smart phone or PC installed the firewall, the security level is set too high, caused the above problem. At this time, only need to close the firewall;
    • Reason 3. The security level of browser is too high, it will also cause the above problem. At this time, just need to reduce the browser’s security level, then log in again;
    • Reason 4. The IP address of the device input error. For the new device from the factory, user only need input the correct IP address according to the instruction guide; for the device that has connected the source hot spot, user only operate according to <Remark 2>.

FCC STATEMENT :

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Operation of this device in the band 5150-5250 MHz is restricted to indoor use only

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VONETS User Manuals

Related Manuals