zoOZ ZSE40 Z-Wave Plus 700 Series 700 4-In-1 Sensor User Manual
- June 5, 2024
- ZOOZ
Table of Contents
zoOZ -ZSE40 Z-Wave- Plus 700 -Series -700 4-In-1 -Sensor
FEATURES
- 4 smart sensors in 1 compact device
- 7 levels of motion sensitivity
- 3 modes for motion/temperature LED indicator notifications
- Built-in tamper protection
- Low battery alerts
- New 700 series Z-Wave chip: faster signal and longer battery life
- S2 Authenticated security with encrypted communication
- SmartStart inclusion for easy and secure pairing
SPECIFICATIONS
- Model Number: ZSE40 700
- Power: 1 CR123A battery
- Range: Up to 200 feet line of sight
- Motion Detection: Up to 35 feet
- Operating Temperature: 5-104° F
- Installation and Use: Indoor only
Z-WAVE CONTROL
- Insert the battery.
- Place the sensor near the location where it will be mounted.
ADD DEVICE to your hub
Initiate inclusion (pairing) in the app (or web interface).
Finalize inclusion at the sensor. Scan the QR code or enter the PIN located under the back cover if your hub supports SmartStart.
CLICK Z-WAVE BUTTON ONCE
SmartStart-enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.
TROUBLESHOOTING
The sensor won’t add to your system?Try this:
- Initiate EXCLUSION and click the Z-Wave button on the sensor once.
- Make sure the battery cover is closed tightly when adding the sensor.
- Click the Z-Wave button once every 15 seconds for 2 minutes aer the sensor joins the network to keep it awake so it can fully configure.
- Click the Z-Wave button on the sensor
- times quickly when adding it.
REMOVE THE SENSOR FROM YOUR HUB
- Bring the sensor within direct range of your Z-Wave gateway (hub).
- Put the Z-Wave hub into exclusion mode (not sure how to do that?ask@getzooz.com).
- Click the Z-Wave button with a paperclip once (it will blink green).
- Your hub will confirm exclusion and the device will disappear from your controller’s device list
FACTORY RESET
If your primary controller is missing or inoperable, you may need to reset the
device to factory settings. To complete the reset process manually, remove the
back cover to trigger tamper switch. Press and release the Z-Wave button using
a paperclip 10 TIMES quickly (within 10 seconds).
NOTE: All previously recorded activity and custom settings will be erased
from the device’s memory.
WAKE-UP MODE
The sensor’s wake-up interval is set to 12 hours by default to save battery
life. You can change the wake-up interval using your controller’s advanced
settings if available. During wake-up, the sensor receives communication from
the hub (setting updates or network information). Long wake-up interval will
not affect how en the sensor reports motion and other values to your gateway
controller. MANUAL WAKE-UP
Press and release the Z-Wave button once to wake the device up. The LED
indicator will flash once (blue or orange). You may need to wake the sensor up
manually IF:
- It doesn’t fully configure during set-up (values are not displayed or errors pop up in your hub’s interface).
- You change advanced settings for the sensor and want them to update.
MOUNTING
OPTION 1: MOUNTING BRACKET Use the 2 screws included in the box to fix the
mounting bracket to flat surface of your choice – at least 7 feet above the
ground for best results.
Once the bracket is securely installed, carefully slide the 4-in-1 sensor onto
the bracket and position it by tilting it to either side, upwards, or
downwards – just like in the images below.
OPTION 2: ADHESIVE TAPE Use the supplied adhesive tape to fix the sensor to a CLEAN flat surface of your choice. Apply the tape as in the pictures below.
INDOOR ONLY!
This sensor may only be used and installed indoors. Outdoor installation will
void its warranty. For best results, mount the sensor within 30 feet from the
door and around 7 feet from the ground. The 4-in-1 Sensor will detect motion
up to 40 feet depending on mounting location and sensitivity settings.
MOTION DETECTION RANGE
See Advanced Settings for ways to optimize and customize motion detection and activity reports.
ADVSPECIFICAANCED SETTINGSTIONS
Please refer to your controller’s user guide for advanced programming
instructions as they are a little different for every soware. Not sure where to
start? Let us know
ASSOCIATION
Associate your 4-in-1 with other Z-Wave devices for direct communication
between them so your rules and automations can take place even if the hub is
down. The 4-in-1 sensor supports Group 1 with up to five devices for Lifeline
communi-cation and Group 2 for basic set reports. To associate the sensor with
other devices, simply put your Z-Wave controller in Association mode by sen-
ding the appropriate command and wake up the sensor by clicking the Z-Wave
button with a paperclip once.
CUSTOMIZE YOUR SENSOR Temperature Sensor
Parameter 1: Use this parameter to switch from Fahrenheit to Celsius scale.
Values: 0 – Celsius. 1 – Fahrenheit (default). Size: 1 byte dec. Parameter 2:
Use it to set temperature change to be reported by the sensor. Values: 1 – 50
(where 1 stands for 0.1 degree and 50 stands for 5 degrees). Default set to 1
degree (value 10). The sensor will report new temperature value to the
controller whenever temperature goes 1 degree up or down. Size: 1 byte dec.
Humidity Sensor
Reports relative humidity.
Parameter 3: Use it to set humidity percentage change to be reported by the
sensor. Parameter 6: Use it to adjust PIR sensor sensitivity.
Values: 1 – 7, where 1 = very high sensitivity and 7 = very low sensitivity.
Default set to 3.
Size: 1 byte dec.
LED notifications
LED indicator will flash whenever you press the Z-Wave button to indicate
temperature level and wake-up mode.
How to read LED indicator colors?
- Green = under 60°F
- Blue = 60°-75°F
- Yellow = 75°-83°F
- Purple = 83°-97°F
- Red = over 97°F / motion detected / tamper switch triggered
- Flashing red = low battery
- Parameter 7: Use it to choose between LED indicator modes.
- Mode 1 = LED indicator is turned off (no visual notifications).
- Mode 2 = temperature and motion indicated with flashing light. Flashes every 3 minutes for temperature.
- Mode 3 = no indication for temperature, motion indicated with red flashing light. Values: 1 – 3. Default set to 3. Size: 1 byte dec.
NOTE : Mode 2 will increase activity and decrease battery life.
Tamper Switch
The tamper switch is located to the le of the battery slot. It’s activated whenever the sensor’s cover is removed while the device is powered up. It will send an alarm notification as scheduled.
This device requires the following command classes to be supported and recognized by your Z-Wave controller:
- COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
- COMMAND_CLASS_ASSOCIATION_V2
- COMMAND_CLASS_MULTICHANNEL_ASSOCIATION_GRP_INFO_V3 COMMAND_CLASS_APPLICATION_STATUS_V1
- COMMAND_CLASS_BATTERY _V1
- COMMAND_CLASS_CONFIGURATION _V4
- COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
- COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
- COMMAND_CLASS_INDICATOR_V3
- COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
- COMMAND_CLASS_NOTIFICATION_V8
- COMMAND_CLASS_POWERLEVEL_V1
- COMMAND_CLASS_SECURITY_V1
- COMMAND_CLASS_SECURITY_2_V1
- COMMAND_CLASS_SENSOR_MULTILEVEL_V11
- COMMAND_CLASS_SUPERVISION_V1
- COMMAND_CLASS_TRANSPORT_SERVICE_V2
- COMMAND_CLASS_VERSION_V3
- COMMAND_CLASS_WAKE_UP_V2
- COMMAND_CLASS_ZWAVEPLUS_INFO_V2
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network.
QUICK GUIDE SCANS
Choose your hub and scan the QR code with your phone’s camera. Then click on the link to access the step-by-step programming instructions.
HOW TO ADD IT TO MY HUB?
HOW TO ADJUST SETTINGS?
HOW DOES IT WORK?
Scan to learn more about how the sensor reports humidity, temperature, and
other values to the hub and how to get the most of it.
WARRANTY
This product is covered under a 5-year limited warranty. To read the full warranty policy or file a warranty claim, please go to www.getzooz.com/warranty
QUESTIONS?
www.support.getzooz.com
ask@getzooz.com
N NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES AND AFFILIATES BE LIABLE FOR ANY
INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL, OR CONSEQUENTIAL DAMAGES, OR DAMAGES
FOR LOSS OF PROFITS, REVENUE, OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY,
WHETHER IN AN ACTION IN CONTRACT OR OTHERWISE EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. ZOOZ’S LIABILITY AND CUSTOMER’S EXCLUSIVE REMEDY
FOR ANY CAUSE OF ACTION ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE
OR USE OF THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH
OF WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES, IS EXPRESSLY
LIMITED TO, AT ZOOZ’S OPTION, REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE
PRICE FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH DA-MAGES ARE CLAIMED.
ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE
OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING WITHIN THIRTY
(30) DAYS FROM ZOOZ’S DELIVERY, OR THE DATE FIXED FOR DELIVERY IN THE EVENT OF
NONDELIVERY.
FCC NOTE
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY
UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID
THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. STORE INDOORS WHEN NOT IN USE.
SUITABLE FOR DRY LOCATIONS ONLY. DO NOT IMMERSE IN WATER. NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions:
- This device may not cause harmful interference,
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used according to instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in any given installation. If this equipment causes harmful interference to radio or television reception, the user may try to correct the interference by taking one or more of the following measures:
- Reorient or relocate receiving antenna
- Increase the separation between equipment and receiver
- Connect equipment into a separate outlet or circuit from receiver
- Consult the dealer or an experienced radio/TV technician for additional assistance
All brand names displayed are trademarks of their respective holders. © Zooz 2021