DYNATRAP DT1750 Mosquito & Insect Trap – Kills Mosquitoes Owner’s Manual

June 5, 2024
09139 AIM USB 4 Altimeter

DYNATRAP DT1750 Mosquito & Insect Trap – Kills Mosquitoes Owner’s

IMPORTANT: READ CAREFULLY IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS

WARNING : When using electric appliances, basic precautions should always be followed, the following:

  1.  Please read all instructions before using the DynaTrap® Insect Trap and keep it for future reference.
  2. To disconnect, turn all controls to the off (“O”) position, then remove the plug from the outlet.
  3.  To reduce the risk of injury from moving parts or electric shock, always turn unit off and disconnect plug before servicing or cleaning.
  4.  Always unplug before replacing the lamp. Replace with same type rated 26-Watt bulb, DynaTrap® model 43050.
  5.  Do not position the unit near heat, gas, oil or other flammable materials.
  6.  Place out of reach from children.
  7.  To reduce the risk of electrical shock, do not put the appliance in water or other liquid.
  8.  Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or if it has been dropped into water or other liquid.
  9.  Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
  10.  Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
  11. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
  12.  Do not clean this product with water spray. Do not place it where it can fall into water, or near flammable materials.
  13.  Do not touch the fan while in motion.
  14.  Do not abuse cord—Never carry or hang unit by a cord or yank it to disconnect from the receptacle. Keep cord away from sharp edges.
  15.  If using outdoors, use only extension cords with a tag stating, “Suitable for Use with Outdoor Appliances.”
  16.  Use only extension cords that have plugs and receptacles that match the product plug. Replace or repair damaged

INSTALLATION & OPERATING INSTRUCTIONS

  1.  Unpack unit. Save carton for off-season storage (if needed).
  2. . If hanging the unit, place approximately 3-6 feet above the floor/ground level for optimal catch rate and easy access for cleaning. Unit can also be placed on the floor or ground
  3.  Plug the cord into an outdoor outlet or extension cord as described in “IMPORTANT SAFETY INSTRUCTIONS”.
  4.  Turn the power switch to “ON” position. The switch is located under the upper housing on the outer rim.
  5.  For best catch results leave unit on at all times, except when cleaning or servicing.
  6.  Catch rate activity will be higher at night. For best catch results it is recommended to keep the unit away from competing for light sources.
  7. It is recommended to place the unit at least 20 to 40 feet away from your outdoor living area.
  8. This unit is all-weather resistant – designed for outdoor use including rainy conditions. Intended for household use only.
  9. To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plugin anyway.
  10. . SERVICING OF DOUBLE-INSULATED APPLIANCES – In a double-insulated appliance, two systems of insulation are provided instead of grounding. No grounding means is provided on a double-insulated appliance, nor should a means for grounding be added to the appliance. Servicing of a double-insulated appliance requires extreme care and knowledge of the system and should be done only by qualified service personnel. Replacement parts for a double-insulated appliance must be identical to those parts in the appliance. The symbol must be identical to those parts in the appliance. A double-insulated appliance is marked with the words “DOUBLE INSULATION”, “DOUBLE-INSULATED” or the symbol:

FCC COMPLIANCE

This device complies with part 18 of the FCC rules. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Frequent cleaning will prolong the life of the unit, ensure fire prevention and provide for more efficient operation.

  1.  Be sure to clean the unit once per week
  2. Switch the unit off and unplug it before cleaning
  3.  Twist the cage clockwise. Remove any buildup from the inside of the retaining cage.

Clean before off-season storage.

IMPORTANT : When replacing the retaining cage – DO NOT press/push against the screen windows. REPLACING BULB Replace With DynaTrap Bulb #43050 (or equivalent G24 Type – 120V/26W Bulb) The light bulb’s life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced regularly to ensure optimal UV effectiveness. Even though the bulb’s light may be visible to you, its ability to attract insects diminishes over time.

  1.  Turn the power switch to the “off” position. UNPLUG UNIT, and allow the bulb to cool before replacing.
    Turn the unit upside down.

  2.  Twist the black threaded fastener piece securing the light housing counterclockwise to loosen. Move the light housing to the side.

  3.  Twist the two black threaded fastener pieces securing the light and carefully remove the silver clips.

  4.  Cover the bulb with a cloth to protect your fingers and hand. Grasp the bulb (with your hand and fingers protected by the cloth) and gently pull the bulb from the socket.

  5. Remove any debris from the lamp socket with a brush before inserting the new bulb. Insert new replacement bulb. Place metal clips in place and secure black threaded fasteners.

Twist the light housing clockwise into place and secure the black threaded fastener.

HOW THE DYNATRAP® INSEC TRAP WORKS

Flying insects are attracted to the unit by the UV light and CO2 that is generated by the photo-catalysis between the UV lamps and the special TiO2 coating. The fan then pulls the insects into the screened base, trapping them until they dehydrate and die. The base can be removed, allowing the contents to be periodically emptied into the trash. Monitor the insects trapped in the retaining cage, through the see-through screen, and empty when the compartment becomes full.

TROUBLESHOOTING

Problem: Possible cause: Correction:
The bulb does not illuminate and the fan does not spin. No electrical power.

1. Check plug, receptacle, and fuse or circuit breaker.
Bulb illuminates, but the fan does not spin.| Shorted fan.| 1.  UNPLUG UNIT: Examine the fan to see that it is free from foreign material, dirt, or the buildup of dead insects.

2.  Clean unit as in the “CLEANING” section.

The fan spins, but the bulb does not illuminate.| 1.  Bulb not seated properly



2.  Burnt out bulb

| 1.  Check bulb socket for any debris and remove, it if necessary. Align the base of the bulb with the socket and press firmly until it is fully seated to ensure electrical contact. The bulb is fully seated when it can no longer move in the socket. Ensure the metal bulb holder is replaced and securely fastened, so the bulb cannot move.

2.  Replace bulb if needed following instructions under “Replacing Bulb”

1-877-403-8727 (TRAP) o dynatrap@woodstream.freshdesk.com.

LIMITED WARRANTY

DYNAMIC warrants to the original purchaser that this product is free from defective materials and workmanship. This warranty is limited to remedy any defective part for a period of one year from date of original date of purchase. Retain your original receipt as proof of purchase. This warranty does not apply to the light bulb, nor to, in our judgment, misuse or abuse. If this unit has been altered, no warranty is in force. This warranty does not apply if this unit is purchased outside the United States, excluding Canada and Mexico. In no case shall DYNAMIC be liable for any accidental, punitive, consequential, or any other damages of any kind for breach of this or any other warranty, expressed or implied, whatsoever. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
REPLACEMENT PARTS: 26-Watt UV Replacement Bulb (1 piece)

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

09139 AIM USB 4 Altimeter User Manuals

Related Manuals