Honeywell 81501 Micro Switch GLS DIN Series Instruction Manual

June 5, 2024
Honeywell

INSTALLATION INSTRUCTIONS FOR THE
MICROSWITCH GLS DIN SERIES
GLOBAL LIMIT SWITCH

81501
Issue 6

Ui 600V ac
Ui 300V dc
UL 50041
EN60947-5-1
EN45545-2 HL 3 (GLA & GLF Series switches only)
EN61373 (GLA Series switches only)

WARNING

IMPROPER INSTALLATION

  • Consult with local safety agencies and their requirements when designing a machine-control link, interface, and all control elements that affect safety.
  • Strictly adhere to all installation instructions.

Failure to comply with these instructions could result in death or serious injury.

MOUNT, WIRE, AND SEAL THE SWITCH
WARNING
IMPROPER OPERATION

  • Ensure the switch actuator achieves sufficient travel for the positive opening of normally closed (NC) contacts to occur.
    Failure to comply with these instructions could result in death or serious injury.
  1. Refer to:
    • Page 5 for adjustments.
    • Pages 9 to 18 for specific travel distances for each switch code, and specifications.
    • Page 5 proper application of limit switches, and switch mounting dimensions.

  2. Perform adjustments (if desired):
    • Head orientation, page 5.
    • Actuation direction (Figure 2, page 5).
    • Side rotary switches with 90* positive drive levers (catalog listings ending in AlA, A1B, A5A, A5B) (Figure 3):
    – Ensure flats of switch shaft engage a groove in actuator lever.
    – Tighten locking screw (A) until tab (B) no longer moves.

  3. Mount switch using four M5 or #10 screws. Torque screws to 4,9 Nm to 5,9 Nm [43 in-lb to 52 in-lb].

  4. Remove screws on the cover plate.

  5. Connect stranded wire (0,75 mm2 to 2,5 mm2, 18-14 AWG) or solid wire (0,75 mm2 to 1,5 mm2, 18-16 AWG) to connector terminals (use 90 C wire when ambient temperature is over 75 C). Torque switch terminal screws to 0,8 Nm to 1,0 Nm [7 in-lb to 9 in-lb]. Wire strip length should be 7,3 mm [0.29 in] max.

  6. Seal conduit opening according to instructions in PK 80112.

  7. Reassemble cover plate, and torque cover screws to 0,5 Nm [4.4 in-lb].

MICROSWITCH GLS DIN LIMIT SWITCH
GLA, GLB, GLF, GLG, GLH SERIES

FIELD ADJUSTABLE HEAD
FIELD VERSTELLBAREM KOPF
CAMPO TESTA REGOLABILE

TERMS BEDINGUNGEN TARIFFE

Contact Closed

Contact Open
Differential Travel
Free Position
Operating Position 1
Positive Opening 1 to IEC 947-5-1
Differential Travel 1
Over Travel
Maximum Operating Force
Maximum Disconnect Force

FIGURE 1.
READING OPERATING SPECIFICATIONS

PRODUCT NOMENCLATURE

Figure 2.
Fixed Lever, Side Rotary Switch – Non-plug-in Body Style, GLZ51 lever, and GLA body

LEVER (catalog listing)| ROLLER MATL| X DIM| Y DIM| Z DIM
---|---|---|---|---
GLZ51A| NYLON| 19,1
.75| 55,9
2.20| 6,4
.25
GLZ51B| STEEL| 19,1
75| 55,9
2.20| 6,4
.25
GLZ51C| NYLON| 24,5
1.00| 59,1
2.33| 12,7
.50
GLZ51Y| RUBBER| 50,0
1.97| 66,1
2.60| 10,0
.39
GLZ51T| STAINLESS
STEEL| 19.1
.75| 56.8
2.24| 8.8
.345

Figure 3.
Fixed Lever, Side Rotary Switch – Plug-in Body Style, GLZ51 lever, and GLB body

Figure 4.
Adjustable Lever Dimensions, GLZ52

LEVER ROLLER MATL X DIM Y DIM Z DIM
GLZ52A NYLON 19,1
.75 65,9
2.59 6,4

.25
GLZ52B| STEEL| 19,1
.75| 65,9
2.59| 6,4
.25
GLZ52D| NYLON| 38,1
1.5| 65,9
2.59| 6,4
.25
GLZ52E| NYLON| 19,1
.75| 79,37
3.125| 33,07
1.300
GLZ52W| RUBBER| 40‘ 0
1.6| 71,5
2.81| 12,7
.5
GLZ52Y| RUBBER| 50‘ 0
1.97| 68,8
2.71| 10,0
.39

Figure 5.
Aluminum Rod Lever Dimensions, GLZ54

Notes:

  • The free position, operate point, over-travel, and pre-travel all to EN 50041
  • Operating characteristics apply to counterclockwise (CCW) and clockwise (CW) actuation
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 6. HEAD CODE: A
SIDE ROTARY ANGULAR OPERATING CHARACTERISTICS

Notes:

  • Cam travel for adjustable lever applies when lever is adjusted to 38,1 mm [1.5 in]
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 7. HEAD CODE: A • SIDE ROTARY CAM ACTUATION PER EN50041 OPERATING CHARACTERISTICS

Notes:

  • The free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 8. HEAD CODE: B
PIN PLUNGER OPERATING CHARACTERISTICS

Notes:

  • Free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 9. HEAD CODE: C
TOP ROLLER PLUNGER PIN ACTUATION OPERATING CHARACTERISTICS

Notes:

  • The free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 10. HEAD CODE: C
ROLLER PLUNGER CAM ACTUATION PER EN50041 OPERATING CHARACTERISTICS

Notes:

  • The free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 11. HEAD CODE: D
TOP ROLLER LEVER PIN ACTUATION OPERATING CHARACTERISTICS

Notes:

  • The free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 12. HEAD CODE: D
TOP ROLLER LEVER CAM ACTUATION PER EN50041 OPERATING CHARACTERISTICS

Head Code: E • WOBBLE AND CAT WHISKER ACTUATOR DIMENSIONS

Figure 13. Coil Actuator

Figure 14. Plastic Rod and Flexible Cable

Figure 15. Cat Whisker Wobbles

Notes:

  • The free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 16. HEAD CODE: E
WOBBLE STICK ANGULAR ACTUATION OPERATING CHARACTERISTICS

Notes:

  • The free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 17. HEAD CODE: K
WOBBLE STICK ANGULAR ACTUATION OPERATING CHARACTERISTICS

WARRANTY/REMEDY

Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to
otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective.
The foregoing is the buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While Honeywell may provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FOR MORE INFORMATION
Honeywell Advanced Sensing Technologies services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the nearest Authorized Distributor,

visit our website or call:
USA/Canada +1 302 613 4491
Latin America +1 305 805 8188
Europe +44 1344 238258
Japan +81 (0) 3-6730-7152
Singapore +65 6355 2828
Greater China +86 4006396841

Honeywell
Advanced Sensing Technologies
830 East Arapaho Road
Richardson, TX 75081
sps.honeywell.com/ast

PK 81501-6-EN | 6 | 06/21
© 2021 Honeywell International Inc. All rights reserved.