Honeywell 81501 Micro Switch GLS DIN Series Instruction Manual
- June 5, 2024
- Honeywell
Table of Contents
INSTALLATION INSTRUCTIONS FOR THE
MICROSWITCH GLS DIN SERIES
GLOBAL LIMIT SWITCH
81501
Issue 6
Ui 600V ac
Ui 300V dc
UL 50041
EN60947-5-1
EN45545-2 HL 3 (GLA & GLF Series switches only)
EN61373 (GLA Series switches only)
WARNING
IMPROPER INSTALLATION
- Consult with local safety agencies and their requirements when designing a machine-control link, interface, and all control elements that affect safety.
- Strictly adhere to all installation instructions.
Failure to comply with these instructions could result in death or serious injury.
MOUNT, WIRE, AND SEAL THE SWITCH
WARNING
IMPROPER OPERATION
- Ensure the switch actuator achieves sufficient travel for the positive opening of normally closed (NC) contacts to occur.
Failure to comply with these instructions could result in death or serious injury.
-
Refer to:
• Page 5 for adjustments.
• Pages 9 to 18 for specific travel distances for each switch code, and specifications.
• Page 5 proper application of limit switches, and switch mounting dimensions. -
Perform adjustments (if desired):
• Head orientation, page 5.
• Actuation direction (Figure 2, page 5).
• Side rotary switches with 90* positive drive levers (catalog listings ending in AlA, A1B, A5A, A5B) (Figure 3):
– Ensure flats of switch shaft engage a groove in actuator lever.
– Tighten locking screw (A) until tab (B) no longer moves. -
Mount switch using four M5 or #10 screws. Torque screws to 4,9 Nm to 5,9 Nm [43 in-lb to 52 in-lb].
-
Remove screws on the cover plate.
-
Connect stranded wire (0,75 mm2 to 2,5 mm2, 18-14 AWG) or solid wire (0,75 mm2 to 1,5 mm2, 18-16 AWG) to connector terminals (use 90 C wire when ambient temperature is over 75 C). Torque switch terminal screws to 0,8 Nm to 1,0 Nm [7 in-lb to 9 in-lb]. Wire strip length should be 7,3 mm [0.29 in] max.
-
Seal conduit opening according to instructions in PK 80112.
-
Reassemble cover plate, and torque cover screws to 0,5 Nm [4.4 in-lb].
MICROSWITCH GLS DIN LIMIT SWITCH
GLA, GLB, GLF, GLG, GLH SERIES
FIELD ADJUSTABLE HEAD
FIELD VERSTELLBAREM KOPF
CAMPO TESTA REGOLABILE
TERMS BEDINGUNGEN TARIFFE
Contact Closed
Contact Open
Differential Travel
Free Position
Operating Position 1
Positive Opening 1 to IEC 947-5-1
Differential Travel 1
Over Travel
Maximum Operating Force
Maximum Disconnect Force
FIGURE 1.
READING OPERATING SPECIFICATIONS
PRODUCT NOMENCLATURE
Figure 2.
Fixed Lever, Side Rotary Switch – Non-plug-in Body Style, GLZ51 lever, and GLA
body
LEVER (catalog listing)| ROLLER MATL| X DIM| Y DIM| Z
DIM
---|---|---|---|---
GLZ51A| NYLON| 19,1
.75| 55,9
2.20| 6,4
.25
GLZ51B| STEEL| 19,1
75| 55,9
2.20| 6,4
.25
GLZ51C| NYLON| 24,5
1.00| 59,1
2.33| 12,7
.50
GLZ51Y| RUBBER| 50,0
1.97| 66,1
2.60| 10,0
.39
GLZ51T| STAINLESS
STEEL| 19.1
.75| 56.8
2.24| 8.8
.345
Figure 3.
Fixed Lever, Side Rotary Switch – Plug-in Body Style, GLZ51 lever, and GLB
body
Figure 4.
Adjustable Lever Dimensions, GLZ52
LEVER | ROLLER MATL | X DIM | Y DIM | Z DIM |
---|---|---|---|---|
GLZ52A | NYLON | 19,1 | ||
.75 | 65,9 | |||
2.59 | 6,4 |
.25
GLZ52B| STEEL| 19,1
.75| 65,9
2.59| 6,4
.25
GLZ52D| NYLON| 38,1
1.5| 65,9
2.59| 6,4
.25
GLZ52E| NYLON| 19,1
.75| 79,37
3.125| 33,07
1.300
GLZ52W| RUBBER| 40‘ 0
1.6| 71,5
2.81| 12,7
.5
GLZ52Y| RUBBER| 50‘ 0
1.97| 68,8
2.71| 10,0
.39
Figure 5.
Aluminum Rod Lever Dimensions, GLZ54
Notes:
- The free position, operate point, over-travel, and pre-travel all to EN 50041
- Operating characteristics apply to counterclockwise (CCW) and clockwise (CW) actuation
- Refer to page 5 for instructions on how to read operating characteristics and specifications
FIGURE 6. HEAD CODE: A
SIDE ROTARY ANGULAR OPERATING CHARACTERISTICS
Notes:
- Cam travel for adjustable lever applies when lever is adjusted to 38,1 mm [1.5 in]
- Refer to page 5 for instructions on how to read operating characteristics and specifications
FIGURE 7. HEAD CODE: A • SIDE ROTARY CAM ACTUATION PER EN50041 OPERATING CHARACTERISTICS
Notes:
- The free position, operate point, overtravel, and pretravel all to EN50041
- Refer to page 5 for instructions on how to read operating characteristics and specifications
FIGURE 8. HEAD CODE: B
PIN PLUNGER OPERATING CHARACTERISTICS
Notes:
- Free position, operate point, overtravel, and pretravel all to EN50041
- Refer to page 5 for instructions on how to read operating characteristics and specifications
FIGURE 9. HEAD CODE: C
TOP ROLLER PLUNGER PIN ACTUATION OPERATING CHARACTERISTICS
Notes:
- The free position, operate point, overtravel, and pretravel all to EN50041
- Refer to page 5 for instructions on how to read operating characteristics and specifications
FIGURE 10. HEAD CODE: C
ROLLER PLUNGER CAM ACTUATION PER EN50041 OPERATING CHARACTERISTICS
Notes:
- The free position, operate point, overtravel, and pretravel all to EN50041
- Refer to page 5 for instructions on how to read operating characteristics and specifications
FIGURE 11. HEAD CODE: D
TOP ROLLER LEVER PIN ACTUATION OPERATING CHARACTERISTICS
Notes:
- The free position, operate point, overtravel, and pretravel all to EN50041
- Refer to page 5 for instructions on how to read operating characteristics and specifications
FIGURE 12. HEAD CODE: D
TOP ROLLER LEVER CAM ACTUATION PER EN50041 OPERATING CHARACTERISTICS
Head Code: E • WOBBLE AND CAT WHISKER ACTUATOR DIMENSIONS
Figure 13. Coil Actuator
Figure 14. Plastic Rod and Flexible Cable
Figure 15. Cat Whisker Wobbles
Notes:
- The free position, operate point, overtravel, and pretravel all to EN50041
- Refer to page 5 for instructions on how to read operating characteristics and specifications
FIGURE 16. HEAD CODE: E
WOBBLE STICK ANGULAR ACTUATION OPERATING CHARACTERISTICS
Notes:
- The free position, operate point, overtravel, and pretravel all to EN50041
- Refer to page 5 for instructions on how to read operating characteristics and specifications
FIGURE 17. HEAD CODE: K
WOBBLE STICK ANGULAR ACTUATION OPERATING CHARACTERISTICS
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective
materials and faulty workmanship. Honeywell’s standard product warranty
applies unless agreed to
otherwise by Honeywell in writing; please refer to your order acknowledgment
or consult your local sales office for specific warranty details. If warranted
goods are returned to
Honeywell during the period of coverage, Honeywell will repair or replace, at
its option, without charge those items it finds defective.
The foregoing is the buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of merchantability and
fitness for a particular purpose. In no event shall Honeywell be liable
for consequential, special, or indirect damages.
While Honeywell may provide application assistance personally, through our
literature and the Honeywell website, it is up to the customer to determine
the suitability of the product in the application.
Specifications may change without notice. The information we supply is
believed to be accurate and reliable as of this printing. However, we assume
no responsibility for its use.
FOR MORE INFORMATION
Honeywell Advanced Sensing Technologies services its customers through a
worldwide network of sales offices and distributors. For application
assistance, current specifications, pricing or the nearest Authorized
Distributor,
visit our website or call:
USA/Canada +1 302 613 4491
Latin America +1 305 805 8188
Europe +44 1344 238258
Japan +81 (0) 3-6730-7152
Singapore +65 6355 2828
Greater China +86 4006396841
Honeywell
Advanced Sensing Technologies
830 East Arapaho Road
Richardson, TX 75081
sps.honeywell.com/ast
PK 81501-6-EN | 6 | 06/21
© 2021 Honeywell International Inc. All rights reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>