Lenovo RackSwitch G7028 Ethernet Switch User Guide
- June 3, 2024
- Lenovo
Table of Contents
Lenovo RackSwitch G7028 Ethernet Switch
RackSwitch G7028
Product Guide (withdrawn product)
The RackSwitch™ G7028 is an inexpensive entry level Layer 2 1/10 Gb Ethernet
switch that is designed for the data center. Datacenter customers continue to
deploy applications using 1 GbE networking switches while 10 GbE continues to
grow for customer solutions requiring greater I/O bandwidth. The RackSwitch
G7028 is an ideal solution for data center customers looking for an economical
1 Gb and 10 Gb connectivity solution. The RackSwitch G7028 (Figure 1) is a
top-of-rack data center switch that delivers excellent non-blocking, wire
speed performance at an attractive price point. It supports twenty-four
10/100/1000BASE-T RJ45 ports and four 10 Gigabit Ethernet SFP+ ports standard,
while typically using only 45 watts of power. The RackSwitch G7028 is also
designed with rear-to-front airflow, which allows for flexible mounting of the
switch in a rack cabinet and provides convenient cable management and
significant savings in cooling costs.
Did you know?
The RackSwitch G7028 is designed with non-blocking, line-rate throughput. The
RackSwitch G7028 supports an optional external redundant power supply with the
G7000 Redundant Power Supply option. The RackSwitch G7028 is designed
specifically for the data center environment with server-matching airflow,
cost-effective Layer 2 switching, and ease of configuration management.
Networking Operating System software features deliver seamless, standards-
based integration into existing upstream switches.
Part number information
The part numbers to order the switch and additional options are shown in Table
Table 1. Part numbers and feature codes for ordering
Description | Part number | Feature code for MTM 7309-HCP |
---|
Switch
RackSwitch G7028| 7309BAX| A4BW
Redundant power supply and DC cables
RackSwitch G7000 Redundant Power Supply| 00AY123| A4BZ
RackSwitch G7000 1.8m DC to DC RPS Power Cable| 00AY121| A4C0
Miscellaneous options
Console Cable Kit Spare| 90Y9462| A2MG
Adjustable 19″ 4 Post Rail Kit| 00D6185| A3KP
Air Inlet Duct for 382 mm RackSwitch| 00D6062| A3HG
The part number for the G7028 switch, 7309BAX, includes the following items:
- One RackSwitch G7028 (rear-to-front airflow) Generic Rack Mount Kit (2-post)
- Power Cord Retention Clip
- RJ-45 to DB-9 serial cable (1.8 m) Warranty Flyer
- Important Notices Flyer
- Documentation CD-ROM
Note: Power cables are not included and must be ordered separately (see
Table 2 for details).
The switch comes standard with the 1.8 m RJ-45 to DB-9 serial management
cable. Additional 1.8 m RJ-45 to DB-9 serial management cables can be ordered
as a part of Console Cable Kit, part number 90Y9462, if required.
The Console cable Kit contains three cables:
- RJ-45 to RJ-45
- Mini-USB to RJ-45
- DB-9 to RJ-45
Lenovo offers the RackSwitch G7000 Redundant Power Supply for those customers requiring redundant power; it can support up to four RackSwitch G7028 or G7052 switches. The G7000 Redundant Power Supply is shown in Figure 2.
RackSwitch G7028 (withdrawn product)
Figure 2. RackSwitch G7000 Redundant Power Supply
Description | Part number | Feature code for MTM 7309-HCP |
---|
Rack power cables
12ft Power Cable C13-C14| 39Y7932| 6263
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable| 39Y7937| 6201
IEC309 C20 to C13 rack jumper cable| 39Y7938| 6204
Line cords
European 10A line C13 to CEE 7/7 (2.8M)| 39Y7917| 6212
Denmark 10A line C13 to DK2-5A (2.8M)| 39Y7918| 6213
Switzerland 10A line C13 to SEV 1011 (2.8M)| 39Y7919| 6216
Israel 10A line C13 to SI 32 (2.8M)| 39Y7920| 6218
Italy 10A line C13 to CEE 7/7 (2.8M)| 39Y7921| 6217
South Africa 10A line C13 to SABS 164/1 (2.8M)| 39Y7922| 6214
United Kingdom 10A line C13 to BS 1363 (2.8M)| 39Y7923| 6215
Australia/NZ 10A line C13 to SAA-AS C112 (2.8M)| 39Y7924| 6211
Korea 7A line C13 to KETI 15A/250V (2.8M)| 39Y7925| 6219
India 6A line C13 to Fig 68 (2.8M)| 39Y7927| 6269
China 6A line C13 to GB 2099.1 (2.8M)| 39Y7928| 6210
Brazil 10A line C13 to NBR 6147 (2.8M)| 39Y7929| 6223
Argentina 10A line C13 to IRAM 2063 (2.8M)| 39Y7930| 6222
Power Cable – C13 / NEMA 5-15P 14ft| 39Y7931| 6207
Power Cord Taiwan AC plug 10A/250V, 2.8M; OPT| 00CG265| A53E
Power Cord Taiwan AC plug 15A/125V; 2.8M; OPT| 00CG267| A53F
10A/250V C13 to NEMA 6-15P 2.8m power cord| 46M2592| A1RF
Japan 10A/100V C13 to JIS C-8303 2.8m power cord| 46M2593| A1RE
The part number for the G7000 Redundant Power Supply, 00AY123, includes the following items:
- One RackSwitch G7000 Redundant Power Supply (rear-to-front airflow) Two 1.8 m DC to DC power cables
- Generic Rack Mount Kit (2-post)
- Power Cord Retention Kit
- Warranty Flyer
- Important Notices Flyer
- Documentation CD-ROM
The G7000 RPS option comes standard with two 1.8 m DC to DC power cables. Additional DC to DC power cables (part number 00AY121; each part number contains one cable) can be ordered if needed. Both the G7028 switch and G7000 RPS option support optional adjustable 19-inch, 4-post rack installation kit, part number 00D6185. Optionally, Air Inlet Duct, part number 00D6062, can be ordered with the G7028 switch or G7000 RPS option for 4-post rack installations. The G7028 switch and G7000 RPS option ship standard without any AC power cables. Table 2 lists the part numbers and feature codes to order the power cables. Table 2. Power cables
Supported cables and transceivers
With the flexibility of the G7028 switch, clients can use the technologies
that they require for the following environments:
- For 1 GbE links, clients can use RJ-45 UTP cables up to 100 meters. Clients that need longer distances can use the SFP/SFP+ ports by using a 1000BASE-SX transceiver, which can drive distances up to 220 meters by using 62.5 µ multi-mode fiber and up to 550 meters with 50 µ multi-mode fiber or the 1000BASE-LX transceivers that support distances up to 10 kilometers by using single-mode fiber (1310 nm).
- For 10 GbE (supported on SFP+ ports), clients can use direct-attached copper (DAC) SFP+ cables for in-rack cabling for distances up to 7 meters. These DAC cables have SFP+ connectors on each end, and they do not need separate transceivers. For longer distances, the 10GBASE-SR transceiver can support distances up to 300 meters over OM3 multimode fiber or up to 400 meters over OM4 multimode fiber with LC connectors. The 10GBASE-LR transceivers can support distances up to 10 kilometers on single-mode fiber with LC connectors.
The supported SFP/SFP+ and DAC cable options are listed in Table 3. Table 3. Supported SFP/SFP+ transceivers and DAC cables
Description| Part number| Feature code (MTM 7309- HCP)|
Maximum quantity supported
---|---|---|---
SFP transceivers – 1 GbE
Lenovo 1000BASE-T SFP Transceiver (does not support 10/100 Mbps)| 00FE333|
A5DL| 4
Lenovo 1000BASE-SX SFP Transceiver| 81Y1622| 3269| 4
Lenovo 1000BASE-LX SFP Transceiver| 90Y9424| A1PN| 4
SFP+ transceivers – 10 GbE
Lenovo 10GBASE-SR SFP+ Transceiver| 46C3447| 5053| 4
Lenovo 10GBASE-LR SFP+ Transceiver| 90Y9412| A1PM| 4
Optical cables for 1 GbE SFP SX and 10 GbE SFP+ SR transceivers
Lenovo 0.5m LC-LC OM3 MMF Cable| 00MN499| ASR5| 4
Lenovo 1m LC-LC OM3 MMF Cable| 00MN502| ASR6| 4
Lenovo 3m LC-LC OM3 MMF Cable| 00MN505| ASR7| 4
Lenovo 5m LC-LC OM3 MMF Cable| 00MN508| ASR8| 4
Lenovo 10m LC-LC OM3 MMF Cable| 00MN511| ASR9| 4
Lenovo 15m LC-LC OM3 MMF Cable| 00MN514| ASRA| 4
Lenovo 25m LC-LC OM3 MMF Cable| 00MN517| ASRB| 4
Lenovo 30m LC-LC OM3 MMF Cable| 00MN520| ASRC| 4
SFP+ passive direct-attach cables – 10 GbE
Lenovo 0.5m Passive SFP+ DAC Cable| 00D6288| A3RG| 4
Lenovo 1m Passive SFP+ DAC Cable| 90Y9427| A1PH| 4
Lenovo 1.5m Passive SFP+ DAC Cable| 00AY764| A51N| 4
Lenovo 2m Passive SFP+ DAC Cable| 00AY765| A51P| 4
Lenovo 3m Passive SFP+ DAC Cable| 90Y9430| A1PJ| 4
Lenovo 5m Passive SFP+ DAC Cable| 90Y9433| A1PK| 4
Lenovo 7m Passive SFP+ DAC Cable| 00D6151| A3RH| 4
SFP+ active direct-attach cables – 10 GbE
Lenovo 1m Active SFP+ DAC Cable| 95Y0323| A25A| 4
Lenovo 3m Active SFP+ DAC Cable| 95Y0326| A25B| 4
Lenovo 5m Active SFP+ DAC Cable| 95Y0329| A25C| 4
Lenovo 1m Active DAC SFP+ Cable (replaces 95Y0323)| 00VX111| AT2R| 4
Lenovo 3m Active DAC SFP+ Cable (replaces 95Y0326)| 00VX114| AT2S| 4
Lenovo 5m Active DAC SFP+ Cable (replaces 95Y0329)| 00VX117| AT2T| 4
Benefits
The RackSwitch G7028 switch is considered particularly suited for these clients:
- Clients who want to leverage GbE in their infrastructure (both servers and networking)
- Clients who are implementing a virtualized environment and require multiple GbE ports
- Clients who require investment protection for 10 GbE ports
- Clients who want to reduce TCO and improve performance while maintaining high levels of availability and security
- Clients who want to avoid or minimize oversubscription, which can result in congestion and loss of performance
- Clients who want to implement a converged infrastructure with NAS or iSCSI
The switch offers the following key benefits:
- Increases network performance The RackSwitch G7028 provides up to 128 Gbps of switching throughput, supports four SFP+ 10 Gb uplink ports for zero oversubscription, and has a port to port latency of 3.3 microseconds.
- Lower power and exceptional cooling The RackSwitch G7028 typically consumes just 45 W of power. Unlike side-cooled switches, which can cause heat recirculation and reliability concerns, the RackSwitch G7028 switch’s rear-to-front cooling design reduces data center air conditioning costs by matching airflow to the server’s configuration in the rack.
- Fault tolerance These switches learn alternative paths automatically and perform faster convergence if there is a link, switch, or power failure. The switch uses technologies such as Virtual Link Aggregation, L2 trunk failover, and HotLinks.
- Seamless interoperability RackSwitch switches interoperate seamlessly with other vendors’ upstream switches.
Features and specifications
The G7028 switch has the following features and specifications:
- Form factor: 1U rack mount switch
- Ports
- Twenty-four 10/100/1000 Mb Ethernet ports with RJ-45 connectors
- Four ports for 1 Gb or 10 Gb Ethernet SFP/SFP+ transceivers (support for 1000BASE-SX, 1000BASE-LX, 1000BASE-T, 10GBASE-SR, or 10GBASE-LR) or SFP+ direct-attach copper
- (DAC) cables. SFP/SFP+ modules or DAC cables are not included and must be purchased separately. One Ethernet port (RJ-45 connector) for out of band (OOB) management
- One RS-232 serial port (RJ-45 connector) that provides an additional means to configure the switch module
- One USB port for mass storage devices
- Scalability and performance
- 10 Gb Ethernet ports for maximum network bandwidth
- Autosensing 10/1000/1000 Gigabit Ethernet ports for bandwidth optimization
- Non-blocking architecture with wire-speed forwarding of traffic; up to 128 Gbps of full duplex switching throughput
- Up to 96 Million packets per second (Mpps) with switching latency of 3.3 microseconds Media access control (MAC) address learning: Automatic update, support of up to 8,000 MAC addresses
- Static and LACP (IEEE 802.3ad) link aggregation
- Support for jumbo frames (up to 12,288 bytes)
- Broadcast/multicast storm control
- IGMP snooping for limit flooding of IP multicast traffic
- IGMP filtering to control multicast traffic for hosts participating in multicast groups Configurable traffic distribution schemes over trunk links based on source/destination IP or MAC \ addresses or both
- Fast port forwarding for rapid STP convergence
- Availability and redundancy
- IEEE 802.1D STP for providing L2 redundancy
- IEEE 802.1s Multiple STP (MSTP) for topology optimization, up to 32 STP instances are supported by single switch
- IEEE 802.1w Rapid STP (RSTP) (provides rapid STP convergence for critical delay-sensitive traffic such as voice or video)
- Per-VLAN Rapid STP (PVRST) enhancements
- Layer 2 Trunk Failover to support active/standby configurations of network adapter teaming on compute nodes
- Hot Links provides basic link redundancy with fast recovery for network topologies that require Spanning Tree to be turned off
- VLAN support
- Port-based and protocol-based VLANs
- Up to 4095 VLANs supported per switch (512 active VLANs), with VLAN numbers 1 – 4095 (4095 is used for management connection only)
- 802.1Q VLAN tagging support on all ports
- 802.1x with Dynamic VLAN assignment
- Private VLANs
- Virtualization
- Virtual Link Aggregation support
- SecurityV
- LAN-based, MAC-based, and IP-based access control lists (ACLs)
- 802.1x port-based authentication
- Multiple user IDs and passwords
- User access control
- Radius, TACACS+ and LDAP authentication and authorization
- Quality of Service (QoS)
- Support for IEEE 802.1p, IP ToS/DSCP, and ACL-based (MAC/IP source and destination addresses, VLANs) traffic classification and processing
- Traffic shaping and re-marking based on defined policies
- Eight priority queues per port for processing qualified traffic
- Weighted random early detection with explicit congestion notification (WRED/ECN)
- CPU priority policies (CoPP)
- IPv4/IPv6 ACL metering
- IP v4 Layer 3 functions
- Host management
- IP filtering with ACLs
- Support for DHCP client
- Support for IGMP snooping and IGMP relay
- IP v6 Layer 3 functions
- IPv6 host management
- IPv6 filtering with ACLs
- Manageability
- Industry-standard CLI (isCLI)
- Simple Network Management Protocol (SNMP V1 and V3)
- HTTP/HTTPS browser GUI
- Telnet interface for CLI
- SSH and SSH v2
- Secure Copy (SCP)
- Serial interface for CLI
- Firmware image update (TFTP and FTP)
- Monitoring
- Switch LEDs for port status and switch module status indication
- Remote Monitoring (RMON) agent to collect statistics and proactively monitor switch performance
- Port mirroring for analyzing network traffic passing through the switch
- Change tracking and remote logging with the syslog feature
The G7000 RPS option has the following features and specifications:
- Form factor: 1U rack mount
- Power connections: Four DC connections in the rear of the rack to connect to the RackSwitch G7028 and G7052 switch; one AC inlet connector to connect to the power source (rack PDU or wall connector)
- Airflow: Rear-to-front cooling
- Power: Approximately 244 W, which varies depending upon operating conditions
- Rack installation: Generic rack-mount kit (2-post); optional flexible 4-post mounting option for both the server rack and the communications rack
- LEDs: System LEDs to indicate status
Standards supported
The G7028 switch supports the following IEEE standards:
- IEEE 802.1D Spanning Tree Protocol (STP)
- IEEE 802.1s Multiple STP (MSTP)
- IEEE 802.1w Rapid STP (RSTP)
- IEEE 802.1p Class of Service (CoS) prioritization
- IEEE 802.1Q Tagged VLAN (frame tagging on all ports when VLANs are enabled)
- IEEE 802.1x port-based authentication
- IEEE 802.3 10BASE-T Ethernet
- IEEE 802.3u 100BASE-TX Fast Ethernet
- IEEE 802.3ab 1000BASE-T copper twisted-pair Gigabit Ethernet
- IEEE 802.3z 1000BASE-SX short range fiber optics Gigabit Ethernet
- IEEE 802.3z 1000BASE-LX long range fiber optics Gigabit Ethernet
- IEEE 802.3ad Link Aggregation Control Protocol
- IEEE 802.3x Full-duplex Flow Control
- IEEE 802.3ae 10GBASE-SR short range fiber optics 10 Gb Ethernet
- IEEE 802.3ae 10GBASE-LR long range fiber optics 10 Gb Ethernet 10GSFP+Cu SFP+ Direct Attach copper
Connectors and LEDs
Figure 3 shows the front panel of the RackSwitch G7028.
Figure 3. Front panel of the RackSwitch G7028
The front panel of the G7028 contains the following components:
- LEDs that display the status of the switch module and the network.
- One RJ-45 RS-232 console port that provides an additional means to configure the switch module.
- Twenty-four 1000BASE-T Ethernet ports for 10/100/1000 Mbps connections.
- Four SFP+ port connectors to attach SFP/SFP+ transceivers for 1 Gb or 10 Gb connections or DAC cables.
- An Ethernet link OK LED and an Ethernet Tx/Rx LED for each Ethernet port on the switch.
Figure 4 shows the rear panel of the RackSwitch G7028.
Figure 4. Rear panel of the RackSwitch G7028
Transceiver | Standard | Cable | Connector |
---|
10 Gb Ethernet
10GBASE-SR SFP+
Transceiver (46C3447)
| 10GBASE-SR| Up to 30 m with fiber optic cables supplied by Lenovo (for more
information, see Table 3); 850 nm OM3 multimode fiber cable up to 300 m or up
to 400 m with OM4 multimode fiber| LC
10GBASE-LR SFP+
Transceiver (90Y9412)
| 10GBASE-LR| 1310 nm single-mode fiber cable up to 10 km| LC
Direct attach cable| 10GSFP+Cu| SFP+ DAC cables up to 7 m (for more
information, see Table 3)| SFP+
1 Gb Ethernet
RJ-45 ports (fixed)| 1000BASE-T| UTP Category 5, 5E, and 6 up to 100 meters|
RJ-45
1000BASE-T SFP
Transceiver (00FE333)
| 1000BASE-T| UTP Category 5, 5E, and 6 up to 100 meters| RJ-45
1000BASE-SX SFP
Transceiver (81Y1622)
| 1000BASE-SX| Up to 30 m with fiber optic cables supplied by Lenovo (for more
information, see Table 3); 850 nm multimode fiber cable up to 550 m (50 µ) or
up to 220 m (62.5 µ)| LC
1000BASE-LX SFP
Transceiver (90Y9424)
| 1000BASE-LX| 1310 nm single-mode fiber cable up to 10 km| LC
Management ports
Ethernet management port| 1000BASE-T| UTP Category 5, 5E, and 6 up to 100
meters| RJ-45
RS-232 serial console port| RS-232| DB-9-to-RJ-45 (comes standard with the
G7028 switch)| RJ-45
The rear panel of the G7028 contains the following components:
- One AC power connector (IEC 320-C14)
- Three fans
- One DC power connector for power supply redundancy
Figure 5 shows the rear panel of the RackSwitch G7000 RPS option .
Figure 5. Rear panel of the RackSwitch G7000 RPS option
Features | Benefits |
---|---|
Line-rate, non-blocking, all 24 ports | Supports compute and virtualization |
workloads
3.3 microseconds latency| Fast application response times
Four 10 GbE uplink ports (40 Gb bandwidth to the core or upstream switch)| No
oversubscription, full upstream throughput
Standards-based Layer 2 protocols, industry standard CLI| Interoperates with
existing network with no learning curve
The rear panel of the G7000 RPS option contains the following components:
- One AC power connector (IEC-320 C14)
- Four DC power connectors
Network cabling requirements
The network cables that can be used with the switch are listed in Table 4.
Table 4. G7028 network cabling requirements
Warranty
The RackSwitch G7028 comes with a limited 3-year hardware warranty with Next Business Day (NBD), 9×5, Customer Replaceable Unit (CRU) warranty service and includes a 3-year software license, which provides entitlement to upgrades over that period. The following optional warranty and maintenance upgrades are available for the G7028 through Lenovo service upgrade offerings:
- Warranty service upgrades (3, 4, or 5 years):
- 24×7 onsite repair with 2-hour target response time
- 24×7 onsite repair with 4-hour target response time
- 9×5 onsite repair with 4-hour target response time
- Maintenance (post-warranty) service offerings (1 or 2 years):
- 24×7 onsite repair with 2-hour target response time
- 24×7 onsite repair with 4-hour target response time
- 9×5 onsite repair with 4-hour target response time
- 9×5 onsite repair with next business day target response time
Lenovo service upgrade offerings are region-specific; that is, each region might have its own service types, service levels, response times, and terms and conditions. Not all covered types of Lenovo service upgrade offerings might be available in a particular region. For more information about the Lenovo warranty service upgrade offerings that are available in your region, visit the Product Selector at the following website: https://www-304.ibm.com/sales/gss/download/spst/servicepac
The RackSwitch G7000 RPS option comes with a limited 1-year hardware warranty with Next NBD, 9×5, CRU warranty service.
Physical specifications
The approximate dimensions and weight of the G7028 switch are as follows:
- Height: 44 mm (1.7 in.)
- Width: 440 mm (17.3 in.)
- Depth: 382 mm (15.0 in.)
- Weight: 5.3 kg (11.7 lb)
The approximate dimensions and weight of the G7000 RPS option are as follows:
- Height: 44 mm (1.7 in.)
- Width: 440 mm (17.3 in.)
- Depth: 382 mm (15.0 in.)
- Weight: 5.4 kg (11.9 lb)
Operating environment
The G7028 switch is supported in the following operating environment:
- Temperature: 0 to 40 ºC.
- Relative humidity: Non-condensing, 10 – 90%
- Altitude: 1,800 m (6,000 feet)
- Acoustic noise: Less than 65 dB
- Typical power: 45 W
The G7000 RPS option is supported in the following operating environment:
- Temperature: 0 to 40 ºC.
- Relative humidity: Non-condensing, 10 – 90%
- Altitude: 1,800 m (6,000 feet)
- Acoustic noise: Less than 65 dB
- Typical power: 245 W
Typical configurations
This section describes popular configurations of the RackSwitch G7028.
Rack-optimized server aggregation of 1 GbE attached rack servers
Some of the typical deployments for the RackSwitch G7028 include Data Center
Top of Rack, Low-Cost L2 connection, and remote offices for various workloads,
such as email, file and print services, collaborative, web serving, and cloud.
Here are examples of possible high-concentration configurations for rack or
blade server implementations:
- System x® and ThinkServer® 1U or 2U servers with a 1 GbE adapter installed
- System x 4U servers with multiple 1 GbE adapters per server
- BladeCenter® or Flex System® using any of the following modules in the chassis:
- BladeCenter Layer 2/3 Copper and Fiber Gigabit Ethernet Switch Modules
- BladeCenter Layer 2-7 Gigabit Ethernet Switch Module
- BladeCenter 1/10 Gb Uplink Ethernet Switch Module
- Intelligent Copper Pass-Thru Module for BladeCenter
- Server Connectivity Module for BladeCenter
- Flex System using EN2092 Ethernet modules in the chassis
Table 5 lists the features and benefits of the RackSwitch G7028 for
server aggregation.
Table 5. Features and benefits of the RackSwitch G7028 for server
aggregation
Figure 6 shows rack-optimized server aggregation for 1 GbE attached rack servers or a Flex System chassis.
Figure 6. Rack-optimized server aggregation for 1GbE attached rack servers or
a Flex System chassis
Server 1 GbE aggregation and connection to storage
Here are the features of the server 1 GbE aggregation and connection to
storage:
A good price/performance point for a data center environment with 1 Gigabit performance and investment protection for 10 GbE
- Good for connectivity to network attached storage (NAS):
- LenovoEMC px4-300r
- LenovoEMC px4-400r
- LenovoEMC px12-400r
- LenovoEMC px12-450r
- Ideal for connectivity to iSCSI:
- Storwize V3700
- Storwize V5000
- Storwize V7000
Figure 7 shows NAS and iSCSI storage connectivity.
Figure 7. NAS and iSCSI storage connectivity
Related publications and links
For more information about the RackSwitch G7028, go to
ibm.com/support/entry/portal/Documentation
and see the following RackSwitch G7028 product resources:
- RackSwitch G7028 Installation Guide
- RackSwitch G7028 isCLI Command Reference
- RackSwitch G7028 Application Guide
- RackSwitch G7028 Browser-Based Interface Quick Guide
Related product families
Product families related to this document are the following:
- 1 Gb Ethernet Connectivity
- Top-of-Rack Switches
Notices
Lenovo may not offer the products, services, or features discussed in this
document in all countries. Consult your local Lenovo representative for
information on the products and services currently available in your area. Any
reference to Lenovo product, program, or service is not intended to state or
imply that only Lenovo product, program, or service may be used. Any
functionally equivalent product, program, or service that does not infringe
any Lenovo intellectual property right may be used instead. However, it is the
user’s responsibility to evaluate and verify the operation of any other
product, program, or service. Lenovo may have patents or pending patent
applications covering the subject matter described in this document. The
furnishing of this document does not give you any license to these patents.
You can send license inquiries, in writing, to:
- Lenovo (United States), Inc.
- 8001 Development Drive
- Morrisville, NC 27560
- U.S.A.
- Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties.
All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo
in the United States, other countries, or both. A current list of Lenovo
trademarks is available on the Web at
https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are
trademarks of Lenovo in the United States, other countries, or both:
- Lenovo®
- BladeCenter®
- Flex System
- LenovoEMC
- RackSwitch
- System x®
- ThinkServer®
ther company, product, or service names may be trademarks or service marks of others.
References
- IBM Support
- 1 Gb Ethernet Connectivity > Lenovo Press
- Top-of-Rack Switches > Lenovo Press
- RackSwitch G7028 Product Guide (withdrawn product) > Lenovo Press
- Copyright and Trademark Information | Lenovo US | Lenovo US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>