AULISA OB0004 Infant Oximeter Box Instruction Manual
- June 5, 2024
- AULISA
Table of Contents
- AULISA OB0004 Infant Oximeter Box
- Disclaimer
- Guide to Symbols
- Precautions for Use
- Device Overview
- Device Set-Up
- Device Pairing
- Device Power Off
- Device Charging
- Alarms
- Care and Maintenance
- Troubleshooting
- Device Performance
- Manufacturer’s Declaration
- FCC Compliance
- Service, Support, and Warranty
- Specifications
- Parts and Accessories
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AULISA OB0004 Infant Oximeter Box
Disclaimer
At the time of publication, this manual is believed to be accurate and up-to- date. In the interest of continued product development, Taiwan Aulisa Medical Devices Technologies, Inc. reserves the right to make changes and improvements to this manual and the products described within at any time, without notice or obligation. References to “Aulisa” in this manual shall imply Taiwan Aulisa Medical Devices Technologies, Inc. Aulisa is a registered trademark of Taiwan Aulisa Medical Devices Technologies, Inc.
CAUTION!!! Read this entire manual carefully before using Guardian Angel® Rx Infant Oximeter.
Taiwan Aulisa Medical Devices Technologies, Inc. No. 218-2, Chong Yang Rd., Nangang Dist.11573 Taipei City , Taiwan Tel.: +886 809 083 100 Distributed by Aulisa Medical USA, Inc. 999 Commercial Street, Suite 208 Palo Alto, CA 94303,USA Tel.: 1.833.828.5472 www.aulisa.com © 2020 Taiwan Aulisa Medical Devices Technologies, Inc.
Guide to Symbols
Welcome
This manual will help you get started with monitoring using the Infant Oximeter Module of Guardian Angel® Rx Digital Vital Sign Monitoring System. The Infant Oximeter Module is intended for use with Guardian Angel® Rx Digital Vital Sign Monitoring System . Refer to the system Instructions for Use for detailed instructions.
Precautions for Use
Contraindications
- Do not use any part of this device in an MRI environment.
- Explosion Hazard: Do not use this device in an explosive atmosphere or in the presence of flammable anesthetics or gases.
- This device is not a replacement for a caregiver.
Warnings
- This device is intended only as an adjunct in patient assessment. It must be used in conjunction with other methods of assessing clinical signs and symptoms.
- A functional tester cannot be used to assess the accuracy of this device. This device does not require calibration.
- This device readings may be affected by the use of an electrosurgical unit.
- Anemia may affect the accuracy of the measurement.
- Only use the accessories manufactured by Aulisa. These accessories are manufactured to meet the accuracy specifications for this device. Using other manufacturers’ components can result in improper device performance and injury may occur.
- The operator must verify the compatibility of the accessories before use, otherwise injury can result.
- As with all medical equipment, carefully route all cables to reduce the possibility of entanglement, strangulation or injury to the patient.
- Be careful with small parts that can be removed from the device and swallowed. They are hazardous to children.
- Excessive pressure to the sensor application site for prolonged periods may cause damage to the skin beneath the sensor probe.
- Do not use this device if it is damaged in any way. Discontinue using it immediately and replace a new one.
- Do not use in or around water or any other liquid when AC power adaptor is used.
- Only use this device with charging adaptors provided by Aulisa.
- This device is designed to determine functional oxygen saturation, the percentage of arterial oxygen saturation of functional hemoglobin. Significant levels of dysfunctional hemoglobin, such as methemoglobin, might affect the accuracy of the measurement.
- Use this device only when it is within the specified distances, approximately 32.8 feet (10 meters) spherical radius to Guardian Angel® Rx Digital Vital Sign Monitoring System. Moving outside this range may cause missing, lost, and/or inaccurate data.
- Loss of monitoring can result if any objects hinder the pulse measurement. Ensure that no blood flow restrictors (e.g. blood pressure cuff) hinder pulse measurements.
- This device is not a substitution for physician supervision.
- Always refer to Instructions For Use for full warnings and instructions.
- Failure to follow instructions and warnings may result in serious injury or death.
Cautions
- This device complies with International Standard IEC 60601-1-2: 2014 for electromagnetic compatibility for medical electrical equipment and/or systems. This standard is designed to provide reasonable protection against harmful interference in a typical medical installation. However, because of the proliferation of radio-frequency transmitting equipment and other sources of electrical noise in healthcare and other environments, it is possible that high levels of interference due to close proximity or strength of a source might disrupt the device’s performance.
- Radios and cell phones or similar devices can affect the wireless connection of this device and must be kept at least 6.5 feet (2 meters) away from it.
- If this device fails to respond as described, discontinue use until the situation is corrected by qualified personnel.
- Cardiogreen and other intravascular dyes may affect the accuracy of SpO2 measurements.
- This device might not work on cold extremities due to reduced circulation. Warm or rub the foot to increase circulation or reposition the sensor.
- This device might misinterpret motion as good pulse quality. Minimize motion
- Excessive ambient light may affect the accuracy of the measurement.
- Inspect and relocate the sensor application site at least every 6 hours to ensure correct sensor alignment and skin integrity. Personal sensitivity to a sensor may vary due to medical status or skin condition.
- Do not place liquids on top of the device.
- Do not immerse the device or any of the components in any liquids.
- Do not use caustic or abrasive cleaning agents on the device.
- Do not gas sterilize or autoclave this device.
- Batteries might leak or explode if used or disposed of improperly.
- Follow local governing ordinances and recycling instructions regarding disposal or recycling of the device and device components, including batteries.
- Do not subject the device to extreme hot or cold temperatures, humidity, or direct sunlight.
- Do not fasten the Leg Band too tightly around the leg. Inaccurate readings and discomfort could result.
- System connection failure (Bluetooth/Wi-Fi wireless connection) may result in loss of data transfer.
Device Overview
Device Components
Device Description
Infant Oximeter Box
The Infant Oximeter Box worn on the leg includes a Bluetooth transmitter and a
sensor chip along with electronics for vital sign measuring and analyzing. It
must be used within 32.8 feet (10 meters) to Guardian Angel® Rx Digital Vital
Sign Monitoring System.
Infant Oximeter Disposable Sensor Cable
The Infant Oximeter Disposable Sensor Cable is intended to be attached to
the Infant Oximeter Box on one end and to the toe on the other end. Discard
the sensor cable after each use. It can be purchased separately.
Infant Oximeter Reusable Sensor Cable
The Infant Oximeter Reusable Sensor Cable is intended to be attached to the
Infant Oximeter Box on one end and to the toe on the other end using the
Adhesive Patch. The sensor cable is reusable. Discard the Adhesive Patch after
each use.
Device Intended Use
The Aulisa Infant Oximeter Module is intended to measure SpO2 and pulse rate
of infant patients during non-motion and under well-perfused conditions in
hospitals, medical facilities, home care, and subacute environments. The
parameters derived by Aulisa Infant Oximeter Module are transmitted to
Aulisa’s Digital Vital Sign Monitoring System for display.
Device Principle of Operation
This device measures SpO2 and pulse rate based on non-invasive light-emitting
diode (LED) reflectance technology, measuring the absorbance of red and
infrared light passed through the perfused tissue during each pulse.
Device Set-Up
Before you begin your monitoring session, unpack the device and become familiar with its parts. It is recommended to fully charge the Infant Oximeter Box prior to setting up. It takes approximately 1 hour to fully charge. Refer to “Device Charging” section for detailed instructions.
-
Step 1: Assemble the device.
Insert the Leg Band through the holder of the Infant Oximeter Box. The fluffy side of the Leg Band should face upward. And then plug in the sensor cable. -
Step 2: Attach the sensor to the toe.
If you go with Infant Oximeter Disposable Sensor Cable, peel off the release paper on the sensor first and wrap the adhesive patch around the toe.
If you go with Infant Oximeter Reusable Sensor Cable, peel off the arch-shaped section of the release paper of the Adhesive Patch, followed by placing the back of the sensor probe over the hole on the center of the patch, and peel off the whole release paper and wrap the patch around the toe.
-
Step 3: Secure the Leg Band around the leg.
-
Step 4: Press the Power button to turn on the Infant Oximeter Box.
NOTE: The power LED will light green when the power is ON. -
Step 5: Set up Guardian Angel® Rx Digital Vital Sign Monitoring System.
NOTE: Refer to the Instructions for Use of Guardian Angel® Rx Digital Vital Sign Monitoring System for set up instructions and verifying system operation. -
Step 6: Wait for the wireless connection of the system to be established. Once connected, the vital signs and the device status information will appear on the MAIN screen.
NOTE: Refer to “Device Pairing” section below for more information.
NOTE: The device must be used within 32.8 feet (10 meters) spherical radius to Guardian Angel® Rx Digital Vital Sign Monitoring System.
NOTE: The power LED on the Infant Oximeter Box will blink green when pairing succeeds, and data transmission starts.
Device Pairing
Automatic Pairing
The system automatically scans and pairs to the Aulisa sensor module(s) from the same starter kit.
NOTE: The device must be placed within 32.8 feet (10 meters) to the Guardian Angel® Rx Digital Vital Sign Monitoring System. NOTE: The Bluetooth connection status icon will turn blue once the pairing succeeds. NOTE: The power LED on the Infant Oximeter Box will blink green when pairing succeeds, and data transmission starts.
Manual Pairing
Follow the below instructions to manually setup pairing of a new Infant
Oximeter Module.
NOTE: Up to four (4) Infant Oximeter can be stored in the system.
- Step 1: Turn on the Infant Oximeter.
- Step 2: In the Setting menu, select “PAIRING”→“SENSOR MODULE”.
- Step 3: Scan the QR Code or key in the serial number located on the back of the Infant Oximeter Box.
- Step 4: Press “CONFIRM” if the serial number (SN) displayed matches with the one on the Infant Oximeter Box.
- Step 5: To confirm that the process was successful, ensure that the Bluetooth connection status icon on the MAIN screen is lit blue.
NOTE: The device remains paired with the system until the serial number
is deleted from the list. NOTE: The device must be placed within 32.8 feet (10
meters) to Guardian Angel® Rx Digital Vital Sign Monitoring System.
NOTE: The Power On/Off LED indicator lights green when the power is ON.
Device Power Off
The device will be turned off by either:
- press the Power button on the Infant Oximeter Box, or
- when the device detects no signal for 3 minutes.
NOTE: The power LED goes off when power off.
Device Charging
The Guardian Angel® Rx Digital Vital Sign Monitoring System will alert the user when the device is on low power. Follow the instructions below to charge the device.
- Step 1: Unplug the sensor cable from the Infant Oximeter Box.
- Step 2: Plug the Type-C end of the charging adaptor into the Infant Oximeter Box.
- Step 3: Attach the wall adaptor to a power outlet .
NOTE: The device works for up to extra 2 hours in the low power status. NOTE: It takes approximately 1 hour to fully charge the device. NOTE: The Power On/Off LED indicator lights blue during charging and goes off when fully charged. NOTE: The device powers off while charging.
CAUTION!!! Only use charging adaptor supplied or manufactured by Taiwan Aulisa Medical Devices Technologies, Inc.
Alarms
The Infant Oximeter Box is equipped with an LED indicator that will blink red when a high priority alarm occurs and blink yellow for medium priority alarm. For more information about the alarm system, refer to the Instructions for Use of Guardian Angel® Rx Digital Vital Sign Monitoring System.
Care and Maintenance
The advanced digital circuitry within the device requires no calibration or periodic maintenance. Field service or repair of this system is not possible. Do not attempt to open the case of the device for that will cause damage and void the warranty. If the device is not functioning properly, see “Troubleshooting” section for more information.
Cleaning and Disinfection
The device is expected to be cleaned and disinfected before use, i.e., once
per day. It has been tested to withstand 300 times of cleaning within 1.5
years of re-use life. Do not use the device that has exceeded its re-use life.
We recommend you clean and disinfect the device with the instructions below.
First, lightly wipe the surface of the device with a soft cloth dampened with
rubbing alcohol for cleaning. Secondly, disinfect the surface of the device
with a soft cloth saturated with a solution of 10% chlorine bleach in tap
water. Lastly, allow the device to dry thoroughly. Visual inspection is
necessary at the end of cleaning and disinfecting cycle. Repeat the previous
cycles to remove visible residual soil on the device. Do not use a visibly
soiled device again.
Reuse Life
This device is reusable with an expected life of 1.5 years. However, if you notice any signs of deterioration from below, stop using it and replace it with a new one or contact Aulisa Customer Support by going online at www.aulisa.com:
- button malfunctions;
- cracks appear on external case;
- edge of the gel covering the sensor probe window starts curling up;
- the strap frays or breaks and the wires inside become exposed.
Using deteriorated component(s) may cause the device performance to degrade and do harm to the user.
CAUTION!!! Do not pour or spray any liquids onto this device, and do not allow any liquids to enter any openings in the device. CAUTION!!! Do not immerse the device in liquid and do not use caustic or abrasive cleaning agents on the device. CAUTION!!! The Infant Oximeter Disposable Sensor Cable is for single use.
Troubleshooting
Problem | Possible Solution |
---|---|
Cannot turn on the device | 1. Make sure the device is kept away from |
any magnetic devices while using.
2. Fully charge the device until the LED blue light
on the Infant Oximeter Box goes off.
Unable to obtain a valid SpO2 or pulse rate reading
NOTE: In some instances, perfusion of person being monitored may be inadequate for pulse detection.
| 1. Reposition the sensor cable and keep it motionless for at least 10 seconds.
2. Relocate the sensor cable to a different site.
3. Make sure the device is assembled firmly and attached to the toe securely.
4. Check the accessories for any visible signs of deterioration.
5. Warm the application site by rubbing or covering with a blanket.
6. Allow the foot to rest comfortably without squeezing or pressing the sensor probe on a hard surface.
7. Make sure the device is within 32.8 feet (10 meters) spherical radius to the Guardian Angel® Rx Digital Vital Sign Monitoring System.
8. Reduce or eliminate any interference. Make sure the device is NOT placed on the same leg being used for other medical therapies or diagnostics (e.g. blood pressure cuff).
9. Check the Guardian Angel® Rx Digital Vital Sign Monitoring System for any alarms or error messages.
10. Check if the device is in low power.
11. Verify the system’s wireless connection.
12. Make sure that the system is not in proximity with other RF radiating devices (such as diathermy, electrocautery, RFID, and security
systems).
Unstable or constant SpO2 and Pulse Rate readings| 1. Shield the sensor probe from any light source.
2. Relocate the sensor cable to a different site.
3. Make sure the device is assembled firmly and attached to the toe securely.
| 4. Check the accessories for any visible signs of deterioration.
5. Reduce motion.
---|---
“—“ appears on the vital sign displays| 1. Make sure the device is
assembled firmly and attached to the toe securely.
2. Reposition the sensor cable and keep it motionless for at least 10 seconds.
3. Relocate the sensor cable to a different site.
4. Make sure the device is within 32.8 feet (10 meters) spherical radius to the Guardian Angel® Rx Digital Vital Sign Monitoring System.
5. Verify the system’s wireless connection.
Data update period has exceeded the limit| 1. Reposition the sensor cable and keep it motionless for at least 10 seconds.
2. Relocate the sensor cable to a different site.
Cannot establish system connection| 1. Make sure the device is within 32.8 feet (10 meters) spherical radius to the Guardian Angel® Rx Digital Vital Sign Monitoring System.
2. Turn off the system and retry.
For additional troubleshooting, refer to the Guardian Angel® Rx Digital Vital Sign Monitoring System Instructions for Use. If these solutions do not correct the problem, please contact your distributor, or contact Aulisa by going online at www.aulisa.com under “Contact Us”.
CAUTION!!! This system is a precision electronic instrument and must be repaired by knowledgeable and specially trained Aulisa personnel only. Do not attempt to open the case or repair the electronics.
Device Performance
SpO2 Accuracy
SpO2 accuracy testing is performed by in vivo accuracy testing under laboratory conditions on healthy subjects with varying skin pigmentation in an independent research laboratory through induced hypoxia studies. Analysis of bias* was performed vs. Hemoximeter data. The limits of agreement shown are calculated per: Bland JM, Altman D. (2007) Agreement between methods of measurement with multiple observations per individual. Journal of Biopharmaceutical Statistics 17, 571 – 582. oot mean square error (RMS error) is calculated as follows:
*Bias is defined as the monitor under test reading minus the hemoximeter reading.
NOTE: Because pulse oximeter equipment measurements are statistically distributed, only about two-thirds of this device measurements can be expected to fall within ±Arms of the value measured by a co-oximeter.
The graph below shows the error (SpO2 – SaO2) plots of each subject measured by this device with upper and lower 95% limits of agreement. Each sample data point is from a clinical study in healthy volunteers.
Pulse Rate Accuracy
Pulse rate accuracy has been functionally tested against an electronic pulse simulator from 30 to 300 bpm in 10bpm intervals, with combinations of Pulse Amplitude settings of 0.5, 1, 3, 5, 7, 10, 12, 15, 17 and 20, and SpO2 settings of 100%, 95%, 90%, 85%, 80%, 75% and 70%. All 1960 combinations of testing points (=7 x 28 x 10) of Pulse Rate passed the ± 3 digits acceptance criteria.
Equipment Response Time
This device uses a moving average to determine the pulse rate and SpO2. The following table shows the equipment response time of this device.
Manufacturer’s Declaration
Refer to the following table for specific information regarding compliance to
IEC 60601-1-2 for this device.
*For all EQUIPMENT and SYSTEMS
Guidance and Manufacturer’s Declaration – Electromagnetic Emission
This device is intended for use in the electromagnetic environment specified below. The
customer and/or user of this device should ensure that it is used in such an environment.
Emissions test
| ****
Compliance
| ****
Electromagnetic environment – guidance
RF emissions CISPR 11
| ****
Group 1
| This device uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby
electronic equipment.
RF emissions
CISPR 11
| ****
Class B
| ****
This device is suitable for use in all establishments, including domestic and those directly connected to the public
low-voltage power supply network that supplies buildings used for domestic purposes.
Harmonic emissions
IEC 61000-3-2
| ****
Complies
Voltage fluctuations/ flicker Emissions
IEC 61000-3-3
| ****
Complies
For all EQUIPMENT and SYSTEMS
Guidance and Manufacturer’s Declaration – Electromagnetic Immunity
This device is intended for use in the electromagnetic environment specified below. The
customer and/or user of this device should ensure that it is used in such an environment.
Immunity test
| IEC 60601-1-2 test
level
| ****
Compliance level
| Electromagnetic
environment -guidance
Electrostatic Discharge (ESD)
IEC 61000-4-2
| ****
±8 kV contact
±15 kV air
| ****
±8 kV contact
±15 kV air
| Floors should be wood, concrete, or ceramic tile. If floors are covered with synthetic material, relative humidity should be at least
30%.
Electrical Fast Transient / Burst
IEC 61000-4-
4
| ****
±2 kV for power supply lines
| ****
±2 kV for power supply lines
| ****
Mains power quality should be that of a typical commercial or hospital environment.
Surge
IEC 61000-4-5
| ****
±1 kV Line to Line
| ****
±1 kV Line to Line
| Mains power quality should be that of a typical commercial or
hospital environment.
Voltage dips, short interruptions, and voltage variations on power supply input lines IEC 61000-4-
11
| 0% UT in 0.5 cycle
at 0°, 45°, 90°,
135°, 180°, 225°,
270°, and 315°
0% UT in 1 cycle at
0°
70% UT in 25/30
cycles at 0°
0% UT in 250/300
cycles at 0° and 180°
| 0% UT in 0.5 cycle
at 0°, 45°, 90°,
135°, 180°, 225°,
270°, and 315°
0% UT in 1 cycle at
0°
70% UT in 25/30
cycles at 0°
0% UT in 250/300
cycles at 0° and 180°
| ****
Mains power quality should be that of a typical commercial or hospital environment.
Power Frequency
(50/60 Hz)
| ****
30 A/m
| ****
30 A/m
| Power frequency magnetic fields
should be at levels
Magnetic Field
IEC 61000-4-8
| | | characteristic of a typical location in a typical commercial or
hospital environment.
---|---|---|---
NOTE: UT is the AC mains voltage before application of the test level.
For EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING
Guidance and Manufacturer’s Declaration – Electromagnetic Immunity
This device is intended for use in the electromagnetic environment specified below. The
customer and/or user of this device should ensure that it is used in such an environment.
Immunity
test
| IEC 60601-1-2
test level
| ****
Compliance level
| Electromagnetic
environment -guidance
Conducted RF IEC 61000-4-6
| ****
3 V
150 kHz to 80 MHz
6 V
ISM and amateur radio bands
| ****
3 V
150 kHz to 80 MHz
6 V
ISM and amateur radio bands
| Portable and mobile RF communications equipment should be used no closer to any part of the device, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey,a should be less than the compliance level in each frequency range.b
Interference may occur in the vicinity of equipment marked with the following symbol:
Radiated RF IEC 61000-
4-3
| ****
10 V
80MHz to 2.7 GHz
| ****
10 V
80MHz to 2.7 GHz
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people.
a. Field strengths from fixed transmitters, such as base stations for radio
(cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an
electromagnetic site survey should be considered. If the measured field strength in
FCC Compliance
Declaration of Conformity with FCC for Electromagnetic Compatibility
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesignated operation.
Federal Communications Commission (FCC) Notice
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy. If not installed and used in accordance with the
instructions, it may cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on. The
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population. The guidelines are based on the safety standards previously set by both U.S. and international standards bodies. This equipment has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/ general population exposure limits specified in ANSI/IEEE Std. C95.1-1992 and has been tested in accordance with the measurement procedures specified in IEEE Std. 1528-200X (Draft 6.5, January 2002).
FCC Radiation Exposure Statement
For body worn operation, to maintain compliance with FCC RF exposure guidelines, use only accessories that contain nonmetallic components. RF exposure separation distance is 5 mm. Use of other accessories may violate FCC RF exposure guidelines and should be avoided. The FCC requires the user to be notified that any changes or modifications to this device that are not expressly approved by Taiwan Aulisa Medical Devices Technologies, Inc. may void the user’s authority to operate the equipment.
CAUTION!!! No modifications to this device are allowed that in any way affect or alter its antenna or antenna configuration.
Service, Support, and Warranty
Taiwan Aulisa Medical Devices Technologies, Inc. (“Aulisa”) warrants to the purchaser that each of Aulisa’s product will be free from material defect for a period of one year from the date of purchase (the “Warranty Period”), and Aulisa will repair or replace at its discretion, free of charge, each Aulisa’s product found to be materially defective during the Warranty Period and for which Aulisa has been notified during the Warranty Period (the “Warranty”). This Warranty shall be the sole and exclusive remedy by the purchaser for the Aulisa product delivered to the purchaser, irrespective whether such remedy is under contract, tort, or by law. Aulisa’s obligation under the Warranty is only if (i) Aulisa has received written notice of the warranty claim within the Warranty Period, (ii) purchaser has returned the product to Aulisa in accordance with instructions provided on Aulisa’s support webpage, and (iii) Aulisa has verified that the product is defective. Aulisa warrants a replacement or repaired product only for products purchased from authorized resellers and only for the unexpired term of the Warranty Period for the defective product. A return merchandise authorization (“RMA”) and its associated RMA number is required before any product can be returned to Aulisa. To obtain this return authorization number, please contact Aulisa Customer Support by going online at www.aulisa.com under “Contact Us”. Under this Warranty, the purchaser is responsible for the cost of delivery of the product to Aulisa’s place of repair as designated by Aulisa, and Aulisa is responsible for the cost of delivery back to the purchaser. Aulisa reserves the right to charge a fee for a warranty repair request on an Aulisa product that is found to be within
Specifications
Dimensions| 1.9″ x 1.8″ x 0.6″
(47.5mm x 46.2mm x 15.9mm)
---|---
Weight| 0.4 oz (12g)
Ingress Protection| IP23
Display Range
Blood Oxygen Saturation (SpO2)| 1-100%
Pulse Rate| 30-300 bpm
Accuracy
Blood Oxygen Saturation (SpO2)| 70-100% ±3 digits
Pulse Rate| 30-300 bpm ±3 digits
Measurement Wavelengths and Output Power
Red| 660 nanometers
Infrared| 940 nanometers
Battery Type| 3.7V battery
Battery Life| 6 hours of continuous operation
Temperature
Operating| +5°C to +40°C
Storage/Transportation| –25°C to +70°C
Humidity
Operating| 15% to 90% R.H. non-condensing
Storage/Transportation| 10% to 93% R.H. non-condensing
Operating Altitude| altitude ≤ 3000 m
Atmospheric Pressure| 700 hPa to 1013 hPa
Wireless Communication
Frequency| 2402-2480 MHz
Protocol| BT4.0
Power Output| 0.0038W
Antenna Info| Chip, 2.5dBi
Security| AES-128
Range| 32.8 feet (10 meters) spherical radius
Direction| Bi-direction
Data rate| Up to 100k Bps
Classifications per IEC 60601- 1|
Type of Protection| Class II, MOPP (on AC power)
| Internally powered (on battery power)
---|---
Type of Protection| Type BF-Applied Part
Mode of Operation| Continuous
Parts and Accessories
Parts and Accessories | Model Number |
---|---|
Infant Oximeter Box | GA-OB0004 |
Infant Oximeter Disposable Sensor Cable | GA-DS0004 |
Infant Oximeter Reusable Sensor Cable | GA-RS0007 |
Adhesive Patch | GA-AP0013 |
Leg Band | GA-LB0002 |
Charging Adaptor | GA-AD0001 |
Infant Oximeter Module (Box + Disposable Sensor Cable) | GA-OM0011 |
Infant Oximeter Module (Box + Reusable Sensor Cable) | GA-OM0009 |
You may also contact your distributor or contact Aulisa by going online at www.aulisa.com under “Contact Us”.
CAUTION!!! Using accessories not by Taiwan Aulisa Medical Devices Technologies, Inc. may result in inaccurate measurements. Always use parts and accessories by Taiwan Aulisa Medical Devices Technologies, Inc.
References
- Aulisa Medical USA - Smart Monitoring for Infants, Children & Adults – Aulisa Medical USA, Inc.
- Aulisa Medical USA - Smart Monitoring For Infants, Children & Adults – Aulisa Medical USA, Inc.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>