MEDIFY AIR MA-45 Air Purifier Instruction Manual
- June 5, 2024
- Medify Air
Table of Contents
MEDIFY AIR MA-45 Air Purifier
READ AND SAVE THESE INSTRUCTIONS INSTRUCTION MANUAL AND WARRANTY INFORMATION
LIFETIME WARRANTY:
IF FILTERS ARE REPLACED ON TIME WITH GENUINE MEDIFY REPLACEMENT FILTERS.
IMPORTANT SAFETY INSTRUCTIONS
WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT, BASIC
SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING.
DANGER – TO REDUCE THE RISK OF ELECTRIC SHOCK:
- Always unplug the air purifier from the electrical outlet immediately after using and before cleaning or replacing filters.
- Keep cord away from heated surfaces.
- Always place the air purifier on a firm, level surface.
- Always place the air purifier at least 3 feet from heat sources such as stoves, radiators, or heaters.
- DO NOT reach for an appliance that has fallen into water. Unplug it immediately.
- DO NOT place or store appliance where it can fall or be pulled into a tub or sink.
- DO NOT place in or drop into water or other liquid.
- Keep dry — DO NOT operate in wet or moist conditions.
- Check your air purifier cord and plug connections. Faulty wall outlet connections or loose plugs can cause the outlet or plug to overheat. Be sure the plug fits tightly in the outlet.
NOTE: This appliance has a polarized plug (one blade is wider than the
other). To reduce the risk of shock, this plug is intended to fit only one way
in a polarized outlet. If the plug does not fit fully in the outlet, reverse
the plug. If it still does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety feature. To do so could result in an
electric shock hazard.
WARNING – TO REDUCE INJURY TO PERSONS:
- Always unplug the air purifier when not in use.
- Do not operate the air purifier with a damaged cord or plug, or has been dropped or damaged in any manner. Contact to www.medifyair.com for examination, electrical or mechanical adjustment, or repair.
- This air purifier is not intended for use in bathroom, laundry areas, and similar moist indoor locations.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic areas where it can be tripped over.
- To disconnect the air purifier, first turn controls to the off position, then remove plug from outlet.
- Do not tilt or move the air purifier while it is in operation. Shut off and remove plug from outlet before moving.
- Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the air purifier.
- Do not block air intakes or exhaust in any manner. Do not use on any soft surface, like a bed, where openings may become blocked.
- Use this air purifier only for its intended use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
- DO NOT use outdoors.
SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE.
UNIQUE FEATURES & SPECIFICATIONS
GENUINE MEDIFY TRUE HEPA H13 FILTRATION SYSTEM
-
TRUE HEPA H13 FILTRATION
Removes up to 99.9% of airborne particles as small as 0.1 microns, such as allergens, pollen, dust, germs, pet dander, odor, mold spores, and smoke from air that passes through the filter. -
CARBON ODOR FILTRATION
Reduces odors and VOCs (volatile organic compounds)/gases as shown by independent laboratory testing. -
PRE-FILTER
Captures large particles.
4 SPEEDS
1,2,3,and 4 speeds
BUILT-IN TIMER
Choose any time from 1 to 12 hours.
REPLACE FILTER INDICATOR
Illuminates when it is time to replace the filter.
SUGGESTED ROOM SIZE
Up to 550 sf every 15 min and up to 1100 sf every 30 min. Portable air
purifiers will be more effective in rooms where all the doors and windows are
closed.
AIR CHANGES PER HOUR
This air purifier will purify the air up to 550 sf every 15 min and up to 1100
sf every 30 min (assuming an 8 FT/2.43 M ceiling) on high speed in a closed
room.
HOW TO USE
BEFORE TURNING THE UNIT ON
- Take the air purifier out of the box and remove the clear protective plastic bag around the filters.
- Mount the air purifier securely on the wall or place the air purifier on a level surface.
- Plug the power cord into a standard AC outlet.
POWER BUTTON AND FAN SPEED SETTINGS
-
To turn the air purifier on, press the power button.
-
This air purifier has 4 fan speed settings: 1,2,3,and 4 speeds. The higher the fan speed setting, the faster the air will be purified. To select or change fan speed, press the fan speed button until the desired setting is reached.
-
TIMER
The Air Purifier can be programmed to turn off after a preset amount of time. Press the button to program the timer. Each press will add
one hour up to a total of 12 hours. Keeping the button pressed will automatically increase to 12 hours, 1 hour at a time. -
DIMMER
Press the dimmer button to change the backlight to desired brightness, there are 4 brightness levels to change for all buttons’ backlight LEDs. The dimmer button backlight will turn off for 1 second when the dimmer button been pressed.
FILTER REPLACEMENT
Filter Indicator Light
when it is time to replace the True HEPA H13 filter based on the air
purifier’s hours of use, a reminder will appear on the LED display to alert
you to change the filters before further use.
REPLACING THE TRUE HEPA H13 FILTER
For optimal performance, replace every 2500 hours under normal usage
conditions. Once the filter has been replaced, press and hold the dimmer
button for 3 seconds to reset the indicator.
-
Unplug the air purifier. Open the filter grille covers on the left and right of the unit by pushing the lock tabs on the top of the covers.
-
Take away the grills from the unit.
-
Pull the tabs to remove the old filter.
-
Install a new genuine Medify replacement filter with the filter Tabs facing out.
-
Align the tabs at the bottom of the grille overs with the unit. Gently push the grille covers until they snap back into place.
-
Plug the power cord into a standard AC outlet. Press and hold the dimmer button f or 3 seconds to reset the indicator.
MA-45WM wall-hanging bracket installation instructions
Preparations before installation
- Installation tools: electric drill, Φ10 drill bit, cross screwdriver, etc;
- Check whether the accessories are complete according to the accessories list;
Installation location selection: must be able to bear the weight of the product and easy to operate, maintain, filter replacement, etc.;
Installation steps
Attach the base to the wall Fix the bracket to the MA-45WM unit.
Attach the MA-45WM unit to the wall
CLEANING AND MAINTENANCE
CLEANING THE PRE-FILTER
NOTE: For best performance, vacuum the pre-filter once a month under normal usage.
- Unplug the air purifier.
- Remove the True HEPA H13 filter as described in the Replacing the True HEPA H13 Filter section.
- Place the True HEPA H13 filter back into the air purifier and cl ose grille.
- Plug the power cord into a standard AC outlet.
FOR BEST PERFORMANCE:
- NEVER use water or any cleaners or detergents to clean the True HEPA H13 filter. Clean off the outside of the unit with a dry cloth as needed.
- NEVER use water, wax, polish, or any chemical solution to clean the outside of the unit.
- Clean off the grille cover using a damp cloth or the brush attachment of your vacuum as needed.
- Replace the True HEPA H13 filter every 2500 hours under normal usage conditions.
- Always use a genuine Medify replacement filters to keep your liefetime warranty active.
TROUBLESHOOTING
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|---|---|
Unit will not operate | • Unit is not plugged in |
• Power button not pressed
• No power to unit
| • Plug unit in
• Press the power button to turn the power on
• Check circuits, fuses, try a different outlet
Reduced airflow| • The back grille may be blocked
• The filter needs to be replaced
| • Make sure side intakes are not blocked or the front outflow area
• Replace the filter
Reduced odor removal| • The filter needs to be replaced| • Replace the
filter
Excessive noise| • The unit is not level or securely mounted to the
wall| • Place the unit on flat,level surface or mount the unit securely on the
wall.
Replace filter light remains lit after filter replacement| • The
replace filter indicator needs to be reset| • Press and hold the DIMMER button
for 3 seconds until the replace filter light turns off
WARRANTY INFORMATION
To register for your lifetime warranty, go to
www.medifyair.com and go to the warranty section
to register your unit. Medify offers a lifetime warranty for parts and service
as long as you are on record as having purchased Genuine Medify Replacement
Filters as directed every 2500 hours of use.
See website for details and easy online registration.