READ AND SAVE THESE INSTRUCTIONS INSTRUCTION MANUAL AND WARRANTY INFORMATION

LIFETIME WARRANTY:

IF FILTERS ARE REPLACED ON TIME WITH GENUINE MODIFY REPLACEMENT FILTERS.

IMPORTANT SAFETY INSTRUCTIONS:

WHEN USING ELECTRICAL PRODUCTS ESPECIALLY WHEN CHILDREN ARE PRESENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING.
DANGER – TO REDUCE THE RISK OF ELECTRIC SHOCK:

  • Alw ys unplug the air purifier from the electrical outlet immediately after using and before cleaning or replacing filters.
  • Keep the cord away from heated surfaces.
  • Always place the air purifier on a firm, level surface.
  • Always place the air purifier at least 6 inches away from walls and 3 feet from heat sources such as stoves, radiators, or heaters.
  • DO NOT reach for an appliance that has fallen into the water. Unplug it immediately.
  • DO NOT place or store appliances where it can fall or be pulled into a tub or sink.
  • DO NOT place in or drop into water or other liquid.
  • Keep dry — DO NOT operate in wet or moist conditions.
  • Check your air purifier cord and plug connections. Faulty wall outlet connections or loose plugs can cause the outlet or plug to overheat. Be sure the plug fits tightly in the outlet.

NOTE: This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety feature. To do so could result in an electric shock hazard.
WARNING- TO REDUCE INJURY TO PERSONS:

  • Always unplug the air purifier when not in use.
  • Do not operate the air purifier with a damaged cord or plug, that has been dropped or damaged in any manner. Contact www.medifyair.com for examination, electrical or mechanical adjustment, or repair.
  • This air purifier is not intended for use in bathrooms, laundry areas, and similar moist indoor locations.
  • Do not run cord under carpeting. Do not cover the cord with throw rugs, runners, or similar coverings. Do not route the cord under furniture or appliances. Arrange the cord away from traffic areas where it can be tripped over.
  • To disconnect the air purifier, first, turn the controls to the off position, then remove the plug from the outlet.
  • Do not tilt or move the air purifier while it is in operation. Shut off and remove the plug from the outlet before moving.
  • Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the air purifier.
  • Do not block air intakes or exhaust in any manner. Do not use it on any soft surface, like a bed, where openings may become blocked.
  • Use this air purifier only for its intended use, as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
  • DO NOT use outdoors.

SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE.

UNIQUE FEATURES & SPECIFICATIONS

GENUINE MEDIFY TRUE HEPA H13 FILTRATION SYSTEM

  • TRUE HEPA H13 FILTRATION
    Removes up to 99.9% of airborne particles as small as 0.1 microns, such as allergens, pollen, dust, germs, pet dander, odor, mold spores, and smoke from air that passes through the filter.

  • CARBON ODOR FILTRATION
    Reduces odors and VOCs (volatile organic compounds)/gases as shown by independent laboratory testing.

  • PRE-FILTER
    Captures large particles.

Noise Levels

Model No.| Noise level for
speed 1 (dB)| Noise level for
speed 2 (dB)| Noise level for
speed 3 (dB)| Noise level for
speed 4 (dB)
MA-50-US| 31.5 dB| 34.9 dB| 48.2 dB| 59.5dB

4 SPEEDS
1, 2, 3, and 4 speeds.
BUILT-IN TIMER
Choose from 2, 4, 8, or 12 hours.
REPLACE FILTER INDICATOR
Illuminates when it is time to replace the filter.

SUGGESTED ROOM SIZE

Up to 550 every 15 min and up to 1100 every 30 min. Portable air purifiers will be more effective in rooms where all the doors and windows are closed.

AIR CHANGES PER HOUR

This air purifier will purify the air up to 550 every 15 min and up to 1100 every 30 min (assuming an 8 FT/2.43 M ceiling) at high speed in a closed room.MEDIFY AIR MA 50 Air Purifier - Fig MEDIFY AIR MA 50 Air Purifier - Fig 1

HOW TO USE

BEFORE TURNING THE UNIT ON

  • Take the air purifier out of the box and remove any outer packaging.
  • Place the air purifier on a firm, level surface.
  • Plug the power cord into a standard AC outlet.

POWER BUTTON AND FAN SPEED SETTINGS

  • To turn the air purifier on, press the power ****button.
  • This air purifier has 4 fan speed settings, 1, 2, 3, and 4. The higher the fan speed setting, the faster the air will be purified. To select or change fan speed, press the fan speed button until the desired setting is reached.

TIMER
Press the timer button until the desired timer setting is lit on the display. The timer button will cycle through the following settings: 2 hours, 4 hours, 8 hours, 12 hours, and off. To cancel the timer at any time, press the timer button until all-timer LEDs are off. The air purifier will run continuously when the timer function is off.
DIMMER
Press the dimmer  button to change the backlight to desired brightness, there are 4 brightness levels to change for all buttons’ backlight LEDs. The dimmer button backlight will turn off for 1 second when the dimmer button has been pressed.
CHILD-LOCK BUTTON
Press the child-lock button and hold for 3 seconds, all functional buttons will be locked. Press and hold again the child-lock button for 3 seconds, all functional buttons will be un-locked.

FILTER REPLACEMENT

REPLACE FILTER LIGHT
when it is time to replace the True HEPA H13 filter based on the air purifier’s hours of use, a reminder will appear on the LED display to alert you to change the filters before further use.
REPLACING THE TRUE HEPA Hl 3 FILTER
For optimal performance, replace every 2500 hours under normal usage conditions. Once the filter has been replaced, press and holds the dimmer button for 3 seconds to reset the indicator.

MEDIFY AIR MA 50 Air Purifier - Fig 2| 1. Unplug the air purifier. Open the filter grill covers on the left and right of the unit by pushing the lock tabs on the top of the covers.
---|---
2. Remove the grill covers from the unit.
3. Pull the tabs to remove the old filter.
MEDIFY AIR MA 50 Air Purifier - Fig 3| 4. Install a new genuine Medify replacement filter with the filter tabs facing out.
5. Align the tabs at the bottom of the grill covers with the unit. Gently push the grill covers until they snap back into place.
6. Plug the power cord into a standard AC outlet. Press and hold the dimmer button for 3 seconds to reset the indicator.

CLEANING AND MAINTENANCE

CLEANING THE PRE-FILTERMEDIFY AIR MA 50 Air Purifier - Fig
4 NOTE: For best performance, vacuum the pre- filter once a month under normal usage.

  1. Unplug the air purifier.
  2. Remove the True HEPA H13 filter as described in the Replacing the True HEPA H13 Filter section.
  3. Place the True HEPA H13 filter back into the air purifier and close the grill.
  4. Plug the power cord into a standard AC outlet.

FOR BEST PERFORMANCE:

  • NEVER use water, any cleaners, or detergents to clean the True HEPA H13 filter.
  • Clean off the outside of the unit with a dry cloth as needed.
  • NEVER use water, wax, polish, or any chemical solution to clean the outside of the unit.
  • Clean off the grill cover using a damp cloth or the brush attachment of your vacuum as needed.
  • Replace the True HEPA H13 filter every 2500 hours under normal usage conditions.
  • Always use a genuine Medify replacement filter to keep your lifetime warranty active.

This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by the US EPA. US EPA does not endorse any manufacturer’s claims of healthier indoor air from the use of this product. The energy efficiency of this ENERGY STAR qualified model is measured based on a ratio between the model’s CADR for dust and the electrical energy it consumes, or CADR/Watt.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE SOLUTION
The unit will not operate •Unit is not plugged in

•Power button not pressed
•No power to the unit| •Plug unit in
•Press the power button to turn the power on
•Check circuits, and fuses, try a different outlet
Reduced airflow| •The back grille may be blocked
•The filter needs to be replaced| •Make sure side intakes are not blocked or the front outflow area
•Replace the filter
Reduced odor removal| •The filter needs to be replaced| •Replace the filter
Excessive noise| •The unit is not level| •Place the unit on a flat, level surface
Replace filter light remains lit after filter replacement| •The replace filter indicator needs to be reset| •Press and hold the DIMMER button for 3 seconds until the replace filter light turns off

WARRANTY INFORMATION

To register for your lifetime warranty, go to www.medifyair.com and go to the warranty section to register your unit. Modify offers a lifetime warranty for parts and service as long as you are on record as having purchased Genuine Medify Replacement Filters as directed every 2500 hours of use.
See the website for details and easy online registration.

Modify Air
1325 SW 30TH AVENUE DEERFIELD BEACH, FL 33442
www.medifyair.com
Contact: info@medifyair.com
Phone: (888)258-1008

Documents / Resources

| MEDIFY AIR MA-50 Air Purifier [pdf] Instruction Manual
MA-50, Air Purifier, MA-50 Air Purifier
---|---
| MEDIFY AIR MA-50 Air Purifier [pdf] Instruction Manual
MA-50, Air Purifier, MA-50 Air Purifier
| MEDIFY AIR MA-50 Air Purifier [pdf] Instruction Manual
MA-50-3.0-US, MA-50, MA-50 Air Purifier, Air Purifier, Purifier
| Medify Air MA-50 Air purifier [pdf] Instruction Manual
MA-50 Air purifier, Air purifier, purifier
| MEDIFY AIR MA-50 Air Purifier [pdf] Instruction Manual
MA-50 Air Purifier, MA-50, Air Purifier, Purifier

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals