DESCRIPTION ON INDOOR UNIT

tuya ISMART 4-Wire Digital Analog Hybrid System - figure
1

Function Description

1 Microphone
2 Speaker
3 TFT-Icd
4 Function button
5 Operation button
6 SD card
7 AC-IN ( 90V-240V)
8 DC-IN:12V-15V
9 Rj45
10 CAM1
11 DOOR1
12 DOOR2
13 CAM2
14 OUT, connect the next indoor unit
15 Input (Connect the Slave monitor)
16 Status Indicator
17 DOOR1 status indicator
18 DOOR2 status indicator
19 Independent Unlock

Panel icon function description

Touch screen icon function definition

WIRING DIAGRAM

1 Tuya Monitor+1 Outdoor unit
tuya ISMART 4-Wire Digital Analog Hybrid System - figure
4

1 Tuya Monitor+2 Outdoor units

tuya ISMART 4-Wire Digital Analog Hybrid System - figure
5

1 Tuya Monitor+1 Outdoor unit+1 CCTV camera

tuya ISMART 4-Wire Digital Analog Hybrid System - figure
6 1Tuya Monitor+1 Slave analog monitor +2 Outdoor units

tuya ISMART 4-Wire Digital Analog Hybrid System - figure
7

1 Tuya Monitor+5 slave Tuya monitors+2 Outdoor units + 2 CCTV Cameras+ Router

tuya ISMART 4-Wire Digital Analog Hybrid System - figure
8| tuya ISMART 4-Wire Digital
Analog Hybrid System - figure 9
---|---

Default setting: Select language and device ID

Please note: The Device ID is an important configuration of the equipment in the system.
It must be configured correctly, Otherwise, it will not work properly. If the current device is connected to the Outdoor unit1, it must be set to 1, and the other Slave monitors must be set 2/3/4/5/6 then work normally.

Note: The input video signal must be accurate, otherwise the video signal will not be displayed correctly. If you cannot accurately know the resolution and format of the input signal, you can use the automatic detection function.

EZ mode

  1. EZ mode, only use the mobile phone to connect the WIFI router and match the WIFI password (Monitor no need to set), as shown below
    tuya ISMART 4-Wire Digital Analog Hybrid System - figure
13tuya ISMART 4-Wire
Digital Analog Hybrid System - figure 14

Precautions

  1. It is better to turn off the data flow when connecting to the network, use WIFI communication, and firstly use WIFI to test whether the network is smooth, the signal is better to be above 90% because the EZ mode uses the broadcast mode, and The strong signal will make the connection easier to succeed.W

Note: If the connection using EZ mode is unsuccessful, generally there are the following points:

  1. The total number of road management mail users is generally 16, 32; 128; most of them The number users is 16, if all users are connected, it will be difficult to reconnect  Access this device through EZ broadcast mode. In this case, you can delete some users, Or use AP connection mode
  2. The encoding and decoding methods of some older WIFI routers are relatively old and do not support EZ Quick connection In this case, you can only connect using AP mode.
  3. If you connect a high-definition WIFI camera to a WIFI router, it will also affect the success rate of the connection, because the high-definition video will take up a lot of bandwidth and cause broadcast interruption during the EZ mode connection, successful configuration will be more difficult. The method can be to first suspend the power supply of the WIFI camera, and then resume the power supply of the camera after the connection is successful, or use the AP mode to connect.
  4. Do not connect more than two devices at the same time under the same router environment, otherwise, they will cross code with each other. You can turn off one of them and then connect the other one.

AP mode

To quickly configure the interface and configure the AP mode in (Settings>Network Interface), note: In (Settings>Network Interface), press the back button to restart the device. (Settings>Network Interface) view the WIFI hotspot name and password.

After restarting as prompted, enter the following interface in turn
tuya ISMART 4-Wire Digital Analog Hybrid System - figure
16Tuya APP operates as follows

tuya ISMART 4-Wire Digital Analog Hybrid System - figure
17

Notes on using APP

  1. If the device has been successfully connected to the user,the user needs to delete the device on the APP before adding it to another user. (note: The user should be deleted  when the network is good, otherwise it’s only deleted on the mobile APP, but not on the server). After deleting, go back to the APP to check and confirm.
  2. If a new user needs to be added again after the machine restores to the factory settings, the current user also needs to delete the device then re-connect. Otherwise, the  device has deleted the password of the router and it’s unable to connect.

App function definition

tuya ISMART 4-Wire Digital Analog Hybrid System - figure
19

  1. Win10 style
    tuya ISMART 4-Wire Digital Analog Hybrid System - figure
21

  2. Android style
    tuya ISMART 4-Wire Digital Analog Hybrid System - figure
22

  3. Standard style
    tuya ISMART 4-Wire Digital Analog Hybrid System - figure
23

Three styles of interface can be set through the menu. No need to restart

Setting

tuya ISMART 4-Wire Digital Analog Hybrid System - figure
24

System

  1. Please format the SD card with the device and copy the files to the corresponding folder. Please note: it must match the corresponding folder.
  2. Restore factory settings: All set parameters are restored to factory mode. Note that Tuya’s device must be deleted together before it can be used again, otherwise it cannot  be added and used by other accounts. Can’t connect to the Internet. ! ! !

Time

  1. (Screen off): Back to system menu 10s later will be off.
  2. (Clock): Standby display time.

Digital Frame
note:

  1. The picture file must be copied to the Digital Frame folder, the picture resolution must not be greater than: 2526×1576, the format is JPEG.
  2. Long press the file to pop up the submenu, select “Delete” or “Delete All”, and click the file to enter the playback interface.

Devices

tuya ISMART 4-Wire Digital Analog Hybrid System - figure
25

  1. If the channel is closed, it will be skipped when monitoring the polling screen. This channel and APP will not display this channel. Please set it carefully.
  2. When Motion Detection Push APP is closed, the phone will not receive any push information.

Ring

tuya ISMART 4-Wire Digital Analog Hybrid System - figure
26

  1. The ringtone of each channel can be set to three time periods,and different ringtone types and volume can be set, but it should, be noted that there can be no gaps and overlaps between the three time periods, otherwise the system will play the default parameters.
  2. Please note that the volume setting of the Door bell cannot be greater than the volume of the indoor unit.

Recording

tuya ISMART 4-Wire Digital Analog Hybrid System - figure
27

  1. Click the file to play directly, long press the file to enter the delete/read operation.

Video interface icon description

tuya ISMART 4-Wire Digital Analog Hybrid System - figure
28

NOTE ON WIRING CONNECTION

Please pay attention to the name marked on the sticker of the machine toavoid wrong connection.Wiring requirements (the actual effect and wire quality are Great elationship):

  1. core ordinary unshielded and shielded wiring cable;

  2. The effective distance from the outdoor camera to the furthest indoor monitor:
    Transmission <30m (4×0.4mm² )
    Transmission <60m (4×0.65mm² )
    tuya ISMART 4-Wire Digital Analog Hybrid System - figure
30

  3. If you want to extend the distance to more than 60m, it is best to choose thick copper core cable, shielded wire or 3-core ordinary unshielded wire + 75-3 video cable.
    Connect the shield terminal to GND.
    Three-wire unshielded cable + SYV75-3 video cable
    tuya ISMART 4-Wire Digital Analog Hybrid System - figure
31 Integrated video surveillance cable with power cord(2×0.5mm² +75-3)
    tuya ISMART 4-Wire Digital Analog Hybrid System - figure
32

  4. If user wants to use CATS or CAT6 network cable.effective distance from the outdoor camera to the furthest indoor monitor will be limited. For unshielded network cable,  the distance will be up to 20m. For shielded network cable, the distance will be up to 40m. So CATS or CAT6 network cable is not recommended.CATS or CAT6  network cable consists of 4 pairs of twisted pairs(8 wires), here one pair of twisted pair will be used as one cable.Green &White+Green, Brown&White+Brown,   Orange&White+Orange, Blue&White+Blue.
    tuya ISMART 4-Wire Digital Analog Hybrid System - figure
33

If it is a shielded wire, it must be connected to GND.

FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device  must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to  provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not  installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur  in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the  user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the user’s  authority to operate the equipment.
The device has been evaluated to meet general RF exposure requirement.
To maintain compliance with FCC’s RF exposure guidelines, the distance must be at least 20 cm between the radiator and your body, and fully supported by the operating and  installation configurations of the transmitter and its antenna(s).

Read User Manual Online (PDF format)